Performance of evaporator collector and air collector in a solar assisted heat pump dryer

A solar assisted heat pump dryer has been designed, fabricated and tested. This paper presents the performance of evaporator-collector and air collector, when operated under same meteorological conditions. ASHRAE standard procedure of collector testing has been followed. The absorber platce of the...

Full description

Bibliographic Details
Main Authors: Rahman, S. M. A., Hawlader, Mohammad Nurul Alam
Format: Book Chapter
Language:English
Published: IIUM Press 2011
Subjects:
Online Access:http://irep.iium.edu.my/20098/
http://irep.iium.edu.my/20098/
http://irep.iium.edu.my/20098/1/performance_of_evaporator_-_C35.pdf
id iium-20098
recordtype eprints
spelling iium-200982012-06-07T00:08:22Z http://irep.iium.edu.my/20098/ Performance of evaporator collector and air collector in a solar assisted heat pump dryer Rahman, S. M. A. Hawlader, Mohammad Nurul Alam TJ Mechanical engineering and machinery A solar assisted heat pump dryer has been designed, fabricated and tested. This paper presents the performance of evaporator-collector and air collector, when operated under same meteorological conditions. ASHRAE standard procedure of collector testing has been followed. The absorber platce of the evaporator-collector is made of copper plate painted black without any glazing. At the bottom of the absorber plate, a tube has been soldered in serpentine form. Areas of the evaporator-collector and air collector are 1.5 m2 and 1.24 m2, respectively. The evaporator-collector of the heat pump is acting directly as the solar collector and the temperature of refrigerant at the inlet to the evaporator-collector always remained below the ambient temperature. Due to rejection of sensible and latent heat of air at the dehumidifier. the temperature at the inlet to the air collector is lower than the ambient air. Hence, the thermal efficieney of the air collector also increases due to a reduction of losses from the collector. The efficiency of evaporator-collector and air collector varied between 0.8 - 0.86 and 0.7 - 0.75, respectively. IIUM Press 2011 Book Chapter PeerReviewed application/pdf en http://irep.iium.edu.my/20098/1/performance_of_evaporator_-_C35.pdf Rahman, S. M. A. and Hawlader, Mohammad Nurul Alam (2011) Performance of evaporator collector and air collector in a solar assisted heat pump dryer. In: Alternative energy. IIUM Press, Kuala Lumpur, pp. 269-282. ISBN 9789674181581 http://rms.research.iium.edu.my/bookstore/default.aspx
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Rahman, S. M. A.
Hawlader, Mohammad Nurul Alam
Performance of evaporator collector and air collector in a solar assisted heat pump dryer
description A solar assisted heat pump dryer has been designed, fabricated and tested. This paper presents the performance of evaporator-collector and air collector, when operated under same meteorological conditions. ASHRAE standard procedure of collector testing has been followed. The absorber platce of the evaporator-collector is made of copper plate painted black without any glazing. At the bottom of the absorber plate, a tube has been soldered in serpentine form. Areas of the evaporator-collector and air collector are 1.5 m2 and 1.24 m2, respectively. The evaporator-collector of the heat pump is acting directly as the solar collector and the temperature of refrigerant at the inlet to the evaporator-collector always remained below the ambient temperature. Due to rejection of sensible and latent heat of air at the dehumidifier. the temperature at the inlet to the air collector is lower than the ambient air. Hence, the thermal efficieney of the air collector also increases due to a reduction of losses from the collector. The efficiency of evaporator-collector and air collector varied between 0.8 - 0.86 and 0.7 - 0.75, respectively.
format Book Chapter
author Rahman, S. M. A.
Hawlader, Mohammad Nurul Alam
author_facet Rahman, S. M. A.
Hawlader, Mohammad Nurul Alam
author_sort Rahman, S. M. A.
title Performance of evaporator collector and air collector in a solar assisted heat pump dryer
title_short Performance of evaporator collector and air collector in a solar assisted heat pump dryer
title_full Performance of evaporator collector and air collector in a solar assisted heat pump dryer
title_fullStr Performance of evaporator collector and air collector in a solar assisted heat pump dryer
title_full_unstemmed Performance of evaporator collector and air collector in a solar assisted heat pump dryer
title_sort performance of evaporator collector and air collector in a solar assisted heat pump dryer
publisher IIUM Press
publishDate 2011
url http://irep.iium.edu.my/20098/
http://irep.iium.edu.my/20098/
http://irep.iium.edu.my/20098/1/performance_of_evaporator_-_C35.pdf
first_indexed 2023-09-18T20:30:09Z
last_indexed 2023-09-18T20:30:09Z
_version_ 1777408681243049984