A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results

This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrosp...

Full description

Bibliographic Details
Main Authors: Jamal, Noriah, Samad Cheung, Humairah, Che Mohamed, Siti Kamariah, Muhammed Nordin, Ellyda
Format: Article
Language:English
Published: Malaysian Nuclear Agency 2013
Subjects:
Online Access:http://irep.iium.edu.my/31076/
http://irep.iium.edu.my/31076/
http://irep.iium.edu.my/31076/1/84-271-1-ED_%281%29_JSNM.pdf
id iium-31076
recordtype eprints
spelling iium-310762013-08-05T03:01:27Z http://irep.iium.edu.my/31076/ A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results Jamal, Noriah Samad Cheung, Humairah Che Mohamed, Siti Kamariah Muhammed Nordin, Ellyda R Medicine (General) This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrospective data were collected from 1128 FFDM images of 282 women from three major ethnic groups (Malay, Chinese and Indian) who underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia from January to March 2008. Results from the present study were then compared with results from the previous study on Screen-Film Mammography System (SFM) according to the ethnic group for both Cranio-caudal (CC) and Mediol-Lateral (MLO) views. We found that the mean kV for CC view for the three ethnic groups are Malay (28), Chinese (28) and Indian (28), and for MLO view are Malay (29), Chinese (28) and Indian (29). These values are higher than the kV for SFM which were Malay (26), Chinese (27) and Indian (26) for CC and Malay (26), Chinese (27) and Indian (26) for CC and MLO views respectively. The mean mAs for CC and MLO views for FFDM were lower compared to SFM systems. These values were Malay (104), Chinese (108) and Indian (91) for CC views and Malay (106), Chinese (105), and Indian (94) for MLO views for the FFDM system. The values for SFM system are for CC and MLO views were Malay (120), Chinese (106) and Indian (126), and Malay (166), Chinese (132), Indian (183) respectively. The median CBT for CC and MLO views increased by 27% and 7% respectively on the FFDM compared to the SFM system. In conclusion, the FFDM operates with higher kV, lower mAs, and higher CBT when compared with SFM system. Median CBT on CC and MLO view with FFDM system are 27% and 7% higher respectively compared to the SFM. We are currently collecting data on mean glandular dose with FFDM systems to assess how the change in local mammography practice influences this value. This will allow comparison with related data from other parts of the world. Malaysian Nuclear Agency 2013 Article PeerReviewed application/pdf en http://irep.iium.edu.my/31076/1/84-271-1-ED_%281%29_JSNM.pdf Jamal, Noriah and Samad Cheung, Humairah and Che Mohamed, Siti Kamariah and Muhammed Nordin, Ellyda (2013) A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results. Jurnal Sains Nuklear Malaysia, 25 (1). pp. 37-42. ISSN 2232-0946 http://jsnm.nuclearmalaysia.gov.my/index.php/jsnm/article/view/84
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic R Medicine (General)
spellingShingle R Medicine (General)
Jamal, Noriah
Samad Cheung, Humairah
Che Mohamed, Siti Kamariah
Muhammed Nordin, Ellyda
A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
description This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrospective data were collected from 1128 FFDM images of 282 women from three major ethnic groups (Malay, Chinese and Indian) who underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia from January to March 2008. Results from the present study were then compared with results from the previous study on Screen-Film Mammography System (SFM) according to the ethnic group for both Cranio-caudal (CC) and Mediol-Lateral (MLO) views. We found that the mean kV for CC view for the three ethnic groups are Malay (28), Chinese (28) and Indian (28), and for MLO view are Malay (29), Chinese (28) and Indian (29). These values are higher than the kV for SFM which were Malay (26), Chinese (27) and Indian (26) for CC and Malay (26), Chinese (27) and Indian (26) for CC and MLO views respectively. The mean mAs for CC and MLO views for FFDM were lower compared to SFM systems. These values were Malay (104), Chinese (108) and Indian (91) for CC views and Malay (106), Chinese (105), and Indian (94) for MLO views for the FFDM system. The values for SFM system are for CC and MLO views were Malay (120), Chinese (106) and Indian (126), and Malay (166), Chinese (132), Indian (183) respectively. The median CBT for CC and MLO views increased by 27% and 7% respectively on the FFDM compared to the SFM system. In conclusion, the FFDM operates with higher kV, lower mAs, and higher CBT when compared with SFM system. Median CBT on CC and MLO view with FFDM system are 27% and 7% higher respectively compared to the SFM. We are currently collecting data on mean glandular dose with FFDM systems to assess how the change in local mammography practice influences this value. This will allow comparison with related data from other parts of the world.
format Article
author Jamal, Noriah
Samad Cheung, Humairah
Che Mohamed, Siti Kamariah
Muhammed Nordin, Ellyda
author_facet Jamal, Noriah
Samad Cheung, Humairah
Che Mohamed, Siti Kamariah
Muhammed Nordin, Ellyda
author_sort Jamal, Noriah
title A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
title_short A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
title_full A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
title_fullStr A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
title_full_unstemmed A survey on physical factors and compressed breast thickness in voluntary mammography screening using FFDM system in Malaysia: preliminary results
title_sort survey on physical factors and compressed breast thickness in voluntary mammography screening using ffdm system in malaysia: preliminary results
publisher Malaysian Nuclear Agency
publishDate 2013
url http://irep.iium.edu.my/31076/
http://irep.iium.edu.my/31076/
http://irep.iium.edu.my/31076/1/84-271-1-ED_%281%29_JSNM.pdf
first_indexed 2023-09-18T20:45:20Z
last_indexed 2023-09-18T20:45:20Z
_version_ 1777409636551360512