Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis

Cimetidine and ranitidine are classified as the H2-receptor antagonists (H2 antagonist). These classes of drugs used to block the action of histamine on parietal cells in the stomach, decreasing the production of acid by these cells. H2 antagonists are widely used in the treatment of gastro oesophag...

Full description

Bibliographic Details
Main Authors: Helaluddin , Abul Bashar Mohammed, Awang, Mohamed, Rahman, Md. Mokhlesur, Khan, Umeed Ali
Format: Conference or Workshop Item
Language:English
English
Published: 2012
Subjects:
Online Access:http://irep.iium.edu.my/32317/
http://irep.iium.edu.my/32317/1/PROCEEDING_COVER.pdf
http://irep.iium.edu.my/32317/2/ID_197_-_pp_669-673_ABM_Helal_Uddin.pdf
id iium-32317
recordtype eprints
spelling iium-323172017-09-05T04:40:50Z http://irep.iium.edu.my/32317/ Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis Helaluddin , Abul Bashar Mohammed Awang, Mohamed Rahman, Md. Mokhlesur Khan, Umeed Ali QD Chemistry RS Pharmacy and materia medica Cimetidine and ranitidine are classified as the H2-receptor antagonists (H2 antagonist). These classes of drugs used to block the action of histamine on parietal cells in the stomach, decreasing the production of acid by these cells. H2 antagonists are widely used in the treatment of gastro oesophageal reflux, gastric and duodenal ulceration. Malaysian government has implemented bio equivalence requirements for manufacturing all generic drugs, cimetidine and ranitidine are also listed with other high demand generic drugs. The study focused on the preliminary chromatographic detection and determination of cimetidine and ranitidine in human plasma which eventually can be used for bioequivalence study of generic formulation of cimetidine and ranitidine. Different sample extraction process were evaluated namely protein precipitation, solvent extraction and solid phase extraction (SPE). It was found for both cimetidine (89%) and ranitidine (87%) showed a better recovery using SPE. With solvent extraction cimetidine showed comparable recovery (85%) using ethyl acetate as a solvent of choice and dichloromethane for ranitidine (82%). For the protein precipitation technique both cimetidine (75%) and ranitidine (73%) showed a lower recovery compared to the other method. HPLC method was used for the analysis of the spiked plasma samples. Chromatographic separation was obtained using a C18 column and mobile phase was a combination of phosphate buffer and acetonitrile. Elution of cimetidine and ranitidine were detected with a UV-Vis detector at 230 nm wavelength. 2012 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/32317/1/PROCEEDING_COVER.pdf application/pdf en http://irep.iium.edu.my/32317/2/ID_197_-_pp_669-673_ABM_Helal_Uddin.pdf Helaluddin , Abul Bashar Mohammed and Awang, Mohamed and Rahman, Md. Mokhlesur and Khan, Umeed Ali (2012) Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis. In: Proceeding of International Conference on Science, Technology & Social Sciences, 20-22 Nov 2012, Kuantan, Pahang.
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic QD Chemistry
RS Pharmacy and materia medica
spellingShingle QD Chemistry
RS Pharmacy and materia medica
Helaluddin , Abul Bashar Mohammed
Awang, Mohamed
Rahman, Md. Mokhlesur
Khan, Umeed Ali
Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
description Cimetidine and ranitidine are classified as the H2-receptor antagonists (H2 antagonist). These classes of drugs used to block the action of histamine on parietal cells in the stomach, decreasing the production of acid by these cells. H2 antagonists are widely used in the treatment of gastro oesophageal reflux, gastric and duodenal ulceration. Malaysian government has implemented bio equivalence requirements for manufacturing all generic drugs, cimetidine and ranitidine are also listed with other high demand generic drugs. The study focused on the preliminary chromatographic detection and determination of cimetidine and ranitidine in human plasma which eventually can be used for bioequivalence study of generic formulation of cimetidine and ranitidine. Different sample extraction process were evaluated namely protein precipitation, solvent extraction and solid phase extraction (SPE). It was found for both cimetidine (89%) and ranitidine (87%) showed a better recovery using SPE. With solvent extraction cimetidine showed comparable recovery (85%) using ethyl acetate as a solvent of choice and dichloromethane for ranitidine (82%). For the protein precipitation technique both cimetidine (75%) and ranitidine (73%) showed a lower recovery compared to the other method. HPLC method was used for the analysis of the spiked plasma samples. Chromatographic separation was obtained using a C18 column and mobile phase was a combination of phosphate buffer and acetonitrile. Elution of cimetidine and ranitidine were detected with a UV-Vis detector at 230 nm wavelength.
format Conference or Workshop Item
author Helaluddin , Abul Bashar Mohammed
Awang, Mohamed
Rahman, Md. Mokhlesur
Khan, Umeed Ali
author_facet Helaluddin , Abul Bashar Mohammed
Awang, Mohamed
Rahman, Md. Mokhlesur
Khan, Umeed Ali
author_sort Helaluddin , Abul Bashar Mohammed
title Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
title_short Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
title_full Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
title_fullStr Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
title_full_unstemmed Evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for HPLC analysis
title_sort evaluation of different extraction method for the isolation of cimetidine and ranitidine from human plasma for hplc analysis
publishDate 2012
url http://irep.iium.edu.my/32317/
http://irep.iium.edu.my/32317/1/PROCEEDING_COVER.pdf
http://irep.iium.edu.my/32317/2/ID_197_-_pp_669-673_ABM_Helal_Uddin.pdf
first_indexed 2023-09-18T20:46:39Z
last_indexed 2023-09-18T20:46:39Z
_version_ 1777409720131256320