The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration

Background Curing of resin composites depends on delivery of adequate total-energy, which may be operator dependent. Aim To determine the effect of inter-incisal opening, cavity location and operator experience on the total-energy delivered to simulated preparations. Design The following were r...

Full description

Bibliographic Details
Main Authors: Santini, Ario, Roebuck, Elizabeth, Harun, Nor Asilah
Format: Article
Language:English
Published: Wiley Blackwell 2013
Subjects:
Online Access:http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/1/the_effect_of_inter-incisor.pdf
id iium-32809
recordtype eprints
spelling iium-328092013-11-18T02:10:28Z http://irep.iium.edu.my/32809/ The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration Santini, Ario Roebuck, Elizabeth Harun, Nor Asilah RK Dentistry Background Curing of resin composites depends on delivery of adequate total-energy, which may be operator dependent. Aim To determine the effect of inter-incisal opening, cavity location and operator experience on the total-energy delivered to simulated preparations. Design The following were recruited: junior dental nurses(5), senior dental nurses(5) and qualified dentists(5). Each operators light cured two simulated restorations in MARC™patient-simulator using a Demi™LCU, for 20 seconds and the total-energy was calculated: (1) tooth 27, Class 1 cavity, inter-incisal opening 25mm and 45mm; (2) tooth 11, Class III cavity. The procedure was repeated 5 times for each simulated cavity. Statistically comparisons (Kruskal-Wallis Test: alpha=0.05) of the following were made: between inter-incisal openings; between location and between the three groups in the total-energy delivered (J/cm² (Mean±SD)). Results Less total-energy was delivered to posterior cavity at 25mm (12.13±5.27 J/cm²) versus at 45mm (16.92±5.64 J/cm²) by all operators (p<0.05). At 45mm, less total-energy delivered to the posterior cavity compared to anterior cavity (25.07±7.35 J/cm²) and it was statically significant (p<0.05). There was no statistically difference between junior nurses and qualified dentists (p>0.05) but there was significant difference in the total-energy delivered between senior nurses (20.07±7.79 J/cm²) and junior nurses (17.49±7.57 J/cm²) and, between senior nurses and qualified dentists (16.55±8.70 J/cm²) (p<0.05). Conclusions Inter-incisal mouth opening, location of the cavity, and operators experience in light curing, affected the total-energy delivered to cavities in a simulated clinical environment. Wiley Blackwell 2013-06 Article PeerReviewed application/pdf en http://irep.iium.edu.my/32809/1/the_effect_of_inter-incisor.pdf Santini, Ario and Roebuck, Elizabeth and Harun, Nor Asilah (2013) The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration. International Journal of Paediatric Dentistry, 23 (Sup 1). p. 208. ISSN 0960-7439 http://onlinelibrary.wiley.com/doi/10.1111/ipd.12037/abstract 10.1111/ipd.12037
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic RK Dentistry
spellingShingle RK Dentistry
Santini, Ario
Roebuck, Elizabeth
Harun, Nor Asilah
The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
description Background Curing of resin composites depends on delivery of adequate total-energy, which may be operator dependent. Aim To determine the effect of inter-incisal opening, cavity location and operator experience on the total-energy delivered to simulated preparations. Design The following were recruited: junior dental nurses(5), senior dental nurses(5) and qualified dentists(5). Each operators light cured two simulated restorations in MARC™patient-simulator using a Demi™LCU, for 20 seconds and the total-energy was calculated: (1) tooth 27, Class 1 cavity, inter-incisal opening 25mm and 45mm; (2) tooth 11, Class III cavity. The procedure was repeated 5 times for each simulated cavity. Statistically comparisons (Kruskal-Wallis Test: alpha=0.05) of the following were made: between inter-incisal openings; between location and between the three groups in the total-energy delivered (J/cm² (Mean±SD)). Results Less total-energy was delivered to posterior cavity at 25mm (12.13±5.27 J/cm²) versus at 45mm (16.92±5.64 J/cm²) by all operators (p<0.05). At 45mm, less total-energy delivered to the posterior cavity compared to anterior cavity (25.07±7.35 J/cm²) and it was statically significant (p<0.05). There was no statistically difference between junior nurses and qualified dentists (p>0.05) but there was significant difference in the total-energy delivered between senior nurses (20.07±7.79 J/cm²) and junior nurses (17.49±7.57 J/cm²) and, between senior nurses and qualified dentists (16.55±8.70 J/cm²) (p<0.05). Conclusions Inter-incisal mouth opening, location of the cavity, and operators experience in light curing, affected the total-energy delivered to cavities in a simulated clinical environment.
format Article
author Santini, Ario
Roebuck, Elizabeth
Harun, Nor Asilah
author_facet Santini, Ario
Roebuck, Elizabeth
Harun, Nor Asilah
author_sort Santini, Ario
title The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
title_short The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
title_full The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
title_fullStr The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
title_full_unstemmed The effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
title_sort effect of inter-incisor opening, cavity location, and operator experience on the energy delivered by light curing unit to simulated dental restoration
publisher Wiley Blackwell
publishDate 2013
url http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/
http://irep.iium.edu.my/32809/1/the_effect_of_inter-incisor.pdf
first_indexed 2023-09-18T20:47:21Z
last_indexed 2023-09-18T20:47:21Z
_version_ 1777409763978510336