Microbial contamination of equipment in the dental laboratory

Objectives: To determine the extent of microbial contamination on the high touch areas of equipment in the dental laboratory. Method: A dental laboratory based cross-sectional study was carried out on four selected high touch areas, which were the vibrator (power switch), the cast trimmer (power sw...

Full description

Bibliographic Details
Main Authors: Cheong, Joo Ming, Hussin, Akbar Sham, Ichwan, Solachuddin J. A., Khalid, Rafiq, Abidin, Sulhi
Format: Conference or Workshop Item
Language:English
Published: 2013
Subjects:
Online Access:http://irep.iium.edu.my/32825/
http://irep.iium.edu.my/32825/1/IADR_Abstract.pdf
id iium-32825
recordtype eprints
spelling iium-328252013-11-25T06:34:18Z http://irep.iium.edu.my/32825/ Microbial contamination of equipment in the dental laboratory Cheong, Joo Ming Hussin, Akbar Sham Ichwan, Solachuddin J. A. Khalid, Rafiq Abidin, Sulhi RK Dentistry Objectives: To determine the extent of microbial contamination on the high touch areas of equipment in the dental laboratory. Method: A dental laboratory based cross-sectional study was carried out on four selected high touch areas, which were the vibrator (power switch), the cast trimmer (power switch) and the denture polisher (power switch & speed control knob). Sterile cotton swabs were used to swab these four areas, smeared onto nutrient agar media and then incubated for 72 hours. The colony forming units (CFU) were counted after 72 hours to determine the extent of microbial contamination. Sample collection was carried out for 3 consecutive days. As a control, the same areas were disinfected and samples were taken exactly as before. Investigation of similar procedure was carried out for another week. A total of 48 sample plates were collected, 24 before disinfection and another 24 after disinfection. Results: A before and after comparison of mean CFU count in the four high touch areas showed both speed control knob (216/54.33) and power switch (189.67/9.83) of the denture polishing machine had the highest CFU count, followed by the cast trimmer (68.17/18) and finally the vibrator (50/7). Before disinfection, the minimum, maximum and mean ± SD bacteria count in 24 plates were 19, 410 and 131.08 ± 105.77 respectively. The minimum, maximum and mean ± (SD) bacteria count in 24 plates after disinfection were 1, 102 and 21.96 ± 28.303 respectively. Reduction in mean of CFU count after surface disinfection using paired T-test was statistically significant (p<0.05). Conclusion: There is high level of bacterial contamination of the high touch areas in the absence of surface disinfection. Therefore, disinfection procedures as are conducted in dental clinic should be implemented in the dental laboratory. Keywords: Dental laboratory, High touch areas, Bacterial contamination, Disinfection 2013-08-21 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/32825/1/IADR_Abstract.pdf Cheong, Joo Ming and Hussin, Akbar Sham and Ichwan, Solachuddin J. A. and Khalid, Rafiq and Abidin, Sulhi (2013) Microbial contamination of equipment in the dental laboratory. In: 2nd Meeting of the International Association for Dental Research- Asia Pacific Region, 21-23 Aug 2013, Plaza Athenee, Bangkok, Thailand.
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic RK Dentistry
spellingShingle RK Dentistry
Cheong, Joo Ming
Hussin, Akbar Sham
Ichwan, Solachuddin J. A.
Khalid, Rafiq
Abidin, Sulhi
Microbial contamination of equipment in the dental laboratory
description Objectives: To determine the extent of microbial contamination on the high touch areas of equipment in the dental laboratory. Method: A dental laboratory based cross-sectional study was carried out on four selected high touch areas, which were the vibrator (power switch), the cast trimmer (power switch) and the denture polisher (power switch & speed control knob). Sterile cotton swabs were used to swab these four areas, smeared onto nutrient agar media and then incubated for 72 hours. The colony forming units (CFU) were counted after 72 hours to determine the extent of microbial contamination. Sample collection was carried out for 3 consecutive days. As a control, the same areas were disinfected and samples were taken exactly as before. Investigation of similar procedure was carried out for another week. A total of 48 sample plates were collected, 24 before disinfection and another 24 after disinfection. Results: A before and after comparison of mean CFU count in the four high touch areas showed both speed control knob (216/54.33) and power switch (189.67/9.83) of the denture polishing machine had the highest CFU count, followed by the cast trimmer (68.17/18) and finally the vibrator (50/7). Before disinfection, the minimum, maximum and mean ± SD bacteria count in 24 plates were 19, 410 and 131.08 ± 105.77 respectively. The minimum, maximum and mean ± (SD) bacteria count in 24 plates after disinfection were 1, 102 and 21.96 ± 28.303 respectively. Reduction in mean of CFU count after surface disinfection using paired T-test was statistically significant (p<0.05). Conclusion: There is high level of bacterial contamination of the high touch areas in the absence of surface disinfection. Therefore, disinfection procedures as are conducted in dental clinic should be implemented in the dental laboratory. Keywords: Dental laboratory, High touch areas, Bacterial contamination, Disinfection
format Conference or Workshop Item
author Cheong, Joo Ming
Hussin, Akbar Sham
Ichwan, Solachuddin J. A.
Khalid, Rafiq
Abidin, Sulhi
author_facet Cheong, Joo Ming
Hussin, Akbar Sham
Ichwan, Solachuddin J. A.
Khalid, Rafiq
Abidin, Sulhi
author_sort Cheong, Joo Ming
title Microbial contamination of equipment in the dental laboratory
title_short Microbial contamination of equipment in the dental laboratory
title_full Microbial contamination of equipment in the dental laboratory
title_fullStr Microbial contamination of equipment in the dental laboratory
title_full_unstemmed Microbial contamination of equipment in the dental laboratory
title_sort microbial contamination of equipment in the dental laboratory
publishDate 2013
url http://irep.iium.edu.my/32825/
http://irep.iium.edu.my/32825/1/IADR_Abstract.pdf
first_indexed 2023-09-18T20:47:22Z
last_indexed 2023-09-18T20:47:22Z
_version_ 1777409765252530176