Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location

Many engineering systems such as aircraft and automotive are considered built-up structures, fabricated from components that are classified as deterministic subsystems (DS)and non-deterministic subsystems (Non-DS). The response of Non-DS is sensitive to uncertainties therefore presents problems in v...

Full description

Bibliographic Details
Main Authors: Wahid, Azni, Abdul Muthalif, Asan Gani, Md Nor, Khairul Affendy
Format: Article
Language:English
Published: Institute of Physics Publishing (UK) 2013
Subjects:
Online Access:http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/1/J-2013-JPCS-Power_input_to_non-deterministic_subsystem_via_piezoelectric.pdf
id iium-34262
recordtype eprints
spelling iium-342622014-01-15T05:56:11Z http://irep.iium.edu.my/34262/ Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location Wahid, Azni Abdul Muthalif, Asan Gani Md Nor, Khairul Affendy TA168 Systems engineering Many engineering systems such as aircraft and automotive are considered built-up structures, fabricated from components that are classified as deterministic subsystems (DS)and non-deterministic subsystems (Non-DS). The response of Non-DS is sensitive to uncertainties therefore presents problems in vibration control. Therefore, analytical solution to estimate average power delivered by a piezoelectric (PZT) patch actuator when attached to a Non-DS needs to be established. The response of Non-DS is estimated using statistical modelling technique such as statistical energy analysis (SEA), in which any external input to the subsystem must be represented in terms of power input. In this paper, ensemble average of power given by a PZT patch actuator to a simply-supported plate when subjected to structural uncertainties is studied using Lagrangian method. The effects of size and location of the PZT actuators on the power delivered to the plate are investigated . It is found that changing the patch location on the structure will not affect the average power supplied while changing the patch size will change the power magnitude proportionally but with some variations at higher frequency. Institute of Physics Publishing (UK) 2013-07-10 Article PeerReviewed application/pdf en http://irep.iium.edu.my/34262/1/J-2013-JPCS-Power_input_to_non-deterministic_subsystem_via_piezoelectric.pdf Wahid, Azni and Abdul Muthalif, Asan Gani and Md Nor, Khairul Affendy (2013) Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location. Journal of Physics: Conference Series, 423 (1). pp. 1-8. ISSN 1742-6588 (P), 1742-6596 (O) http://iopscience.iop.org/1742-6596/423/1/012065 10.1088/1742-6596/423/1/012065
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TA168 Systems engineering
spellingShingle TA168 Systems engineering
Wahid, Azni
Abdul Muthalif, Asan Gani
Md Nor, Khairul Affendy
Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
description Many engineering systems such as aircraft and automotive are considered built-up structures, fabricated from components that are classified as deterministic subsystems (DS)and non-deterministic subsystems (Non-DS). The response of Non-DS is sensitive to uncertainties therefore presents problems in vibration control. Therefore, analytical solution to estimate average power delivered by a piezoelectric (PZT) patch actuator when attached to a Non-DS needs to be established. The response of Non-DS is estimated using statistical modelling technique such as statistical energy analysis (SEA), in which any external input to the subsystem must be represented in terms of power input. In this paper, ensemble average of power given by a PZT patch actuator to a simply-supported plate when subjected to structural uncertainties is studied using Lagrangian method. The effects of size and location of the PZT actuators on the power delivered to the plate are investigated . It is found that changing the patch location on the structure will not affect the average power supplied while changing the patch size will change the power magnitude proportionally but with some variations at higher frequency.
format Article
author Wahid, Azni
Abdul Muthalif, Asan Gani
Md Nor, Khairul Affendy
author_facet Wahid, Azni
Abdul Muthalif, Asan Gani
Md Nor, Khairul Affendy
author_sort Wahid, Azni
title Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
title_short Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
title_full Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
title_fullStr Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
title_full_unstemmed Power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
title_sort power input to non-deterministic subsystems via piezoelectric patch actuators: effect of the patch size and location
publisher Institute of Physics Publishing (UK)
publishDate 2013
url http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/
http://irep.iium.edu.my/34262/1/J-2013-JPCS-Power_input_to_non-deterministic_subsystem_via_piezoelectric.pdf
first_indexed 2023-09-18T20:49:25Z
last_indexed 2023-09-18T20:49:25Z
_version_ 1777409893741887488