Evaluation of various leakage current paths with different switching conditions
The Photovoltaic (PV) panel is the arrangement of solar cells that becoming famous in the world for commercial electric power market via transformer-less topology. However, non-existing galvanic isolation is the biggest problem occurred in the whole system and is known as leakage issue. In this pape...
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
2014
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/40281/ http://irep.iium.edu.my/40281/ http://irep.iium.edu.my/40281/1/40281_edited.pdf http://irep.iium.edu.my/40281/4/40281_Evaluation%20of%20various%20leakage%20current%20paths%20with%20different_Scopus.pdf |
Summary: | The Photovoltaic (PV) panel is the arrangement of solar cells that becoming famous in the world for commercial electric power market via transformer-less topology. However, non-existing galvanic isolation is the biggest problem occurred in the whole system and is known as leakage issue. In this paper, different paths of leakage current were analyzed with various wave shapes and ranges. Furthermore, it was also verified using DC decoupling and AC decoupling with full bridge rectifier. Moreover, the EMC filter and high range load were used to evaluate the performance. Moreover, here also shown the transfer function of EMC filter with its simulated figure. |
---|