Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K

Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973 and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone. The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The...

Full description

Bibliographic Details
Main Authors: Setiawan, Asep Ridwan, Ani, Mohd Hanafi, Ueda, Mitsutoshi, Kawamura, Kenichi, Maruyama, Toshio
Format: Article
Language:English
Published: The Iron and Steel Institute of Japan 2010
Subjects:
Online Access:http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf
id iium-4104
recordtype eprints
spelling iium-41042011-10-19T02:51:09Z http://irep.iium.edu.my/4104/ Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K Setiawan, Asep Ridwan Ani, Mohd Hanafi Ueda, Mitsutoshi Kawamura, Kenichi Maruyama, Toshio TA401 Materials of engineering and construction Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973 and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone. The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The calculated oxygen permeability increases linearly with increasing Cr concentration in the alloys, both at 973 and 1 073 K. Moreover, the presence of humidity enhanced the oxygen permeability compared with that under dry condition. The oxygen permeability through IOZ in humid atmosphere is larger than that in dry atmosphere as a factor of 1.2. The Iron and Steel Institute of Japan 2010 Article PeerReviewed application/pdf en http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf Setiawan, Asep Ridwan and Ani, Mohd Hanafi and Ueda, Mitsutoshi and Kawamura, Kenichi and Maruyama, Toshio (2010) Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K. ISIJ International, 50 (2). pp. 259-263. ISSN 1347-5460 (O), 0915-1559 (P) http://www.jstage.jst.go.jp/article/isijinternational/50/2/50_259/_article doi:10.2355/isijinternational.50.259
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TA401 Materials of engineering and construction
spellingShingle TA401 Materials of engineering and construction
Setiawan, Asep Ridwan
Ani, Mohd Hanafi
Ueda, Mitsutoshi
Kawamura, Kenichi
Maruyama, Toshio
Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
description Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973 and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone. The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The calculated oxygen permeability increases linearly with increasing Cr concentration in the alloys, both at 973 and 1 073 K. Moreover, the presence of humidity enhanced the oxygen permeability compared with that under dry condition. The oxygen permeability through IOZ in humid atmosphere is larger than that in dry atmosphere as a factor of 1.2.
format Article
author Setiawan, Asep Ridwan
Ani, Mohd Hanafi
Ueda, Mitsutoshi
Kawamura, Kenichi
Maruyama, Toshio
author_facet Setiawan, Asep Ridwan
Ani, Mohd Hanafi
Ueda, Mitsutoshi
Kawamura, Kenichi
Maruyama, Toshio
author_sort Setiawan, Asep Ridwan
title Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
title_short Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
title_full Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
title_fullStr Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
title_full_unstemmed Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
title_sort oxygen permeability through internal oxidation zone in fe–cr alloys under dry and humid conditions at 973 and 1 073 k
publisher The Iron and Steel Institute of Japan
publishDate 2010
url http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/
http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf
first_indexed 2023-09-18T20:12:12Z
last_indexed 2023-09-18T20:12:12Z
_version_ 1777407552184647680