Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K
Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973 and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone. The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Iron and Steel Institute of Japan
2010
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf |
id |
iium-4104 |
---|---|
recordtype |
eprints |
spelling |
iium-41042011-10-19T02:51:09Z http://irep.iium.edu.my/4104/ Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K Setiawan, Asep Ridwan Ani, Mohd Hanafi Ueda, Mitsutoshi Kawamura, Kenichi Maruyama, Toshio TA401 Materials of engineering and construction Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973 and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone. The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The calculated oxygen permeability increases linearly with increasing Cr concentration in the alloys, both at 973 and 1 073 K. Moreover, the presence of humidity enhanced the oxygen permeability compared with that under dry condition. The oxygen permeability through IOZ in humid atmosphere is larger than that in dry atmosphere as a factor of 1.2. The Iron and Steel Institute of Japan 2010 Article PeerReviewed application/pdf en http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf Setiawan, Asep Ridwan and Ani, Mohd Hanafi and Ueda, Mitsutoshi and Kawamura, Kenichi and Maruyama, Toshio (2010) Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K. ISIJ International, 50 (2). pp. 259-263. ISSN 1347-5460 (O), 0915-1559 (P) http://www.jstage.jst.go.jp/article/isijinternational/50/2/50_259/_article doi:10.2355/isijinternational.50.259 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
TA401 Materials of engineering and construction |
spellingShingle |
TA401 Materials of engineering and construction Setiawan, Asep Ridwan Ani, Mohd Hanafi Ueda, Mitsutoshi Kawamura, Kenichi Maruyama, Toshio Oxygen permeability through internal oxidation zone in Fe–Cr alloys under dry and humid conditions at 973 and 1 073 K |
description |
Internal oxidation of Fe–Cr alloys were investigated in dry and humid atmospheres at temperatures of 973
and 1 073 K in order to clarify the effect of humidity on the oxygen permeability in internal oxidation zone.
The oxygen partial pressure in the chamber was fixed by Fe/FeO powder mixture. The calculated oxygen
permeability increases linearly with increasing Cr concentration in the alloys, both at 973 and 1 073 K. Moreover,
the presence of humidity enhanced the oxygen permeability compared with that under dry condition.
The oxygen permeability through IOZ in humid atmosphere is larger than that in dry atmosphere as a factor
of 1.2. |
format |
Article |
author |
Setiawan, Asep Ridwan Ani, Mohd Hanafi Ueda, Mitsutoshi Kawamura, Kenichi Maruyama, Toshio |
author_facet |
Setiawan, Asep Ridwan Ani, Mohd Hanafi Ueda, Mitsutoshi Kawamura, Kenichi Maruyama, Toshio |
author_sort |
Setiawan, Asep Ridwan |
title |
Oxygen permeability through internal oxidation zone in Fe–Cr
alloys under dry and humid conditions at 973 and 1 073 K |
title_short |
Oxygen permeability through internal oxidation zone in Fe–Cr
alloys under dry and humid conditions at 973 and 1 073 K |
title_full |
Oxygen permeability through internal oxidation zone in Fe–Cr
alloys under dry and humid conditions at 973 and 1 073 K |
title_fullStr |
Oxygen permeability through internal oxidation zone in Fe–Cr
alloys under dry and humid conditions at 973 and 1 073 K |
title_full_unstemmed |
Oxygen permeability through internal oxidation zone in Fe–Cr
alloys under dry and humid conditions at 973 and 1 073 K |
title_sort |
oxygen permeability through internal oxidation zone in fe–cr
alloys under dry and humid conditions at 973 and 1 073 k |
publisher |
The Iron and Steel Institute of Japan |
publishDate |
2010 |
url |
http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/ http://irep.iium.edu.my/4104/1/oxygen_permeability_through_internal_oxidation_zone_in_fe-cr_alloys_under_dry_and_humid_conditions_at_973_and_1073_k.pdf |
first_indexed |
2023-09-18T20:12:12Z |
last_indexed |
2023-09-18T20:12:12Z |
_version_ |
1777407552184647680 |