Multi-directional radiation detector using photographic film

Ionising radiation has always been part of our surrounding and people are continuously exposed to it. Ionising radiation is harmful to human health, thus it is vital to monitor the radiation. To monitor radiation, there are three main points that should be observed cautiously, which are energy, quan...

Full description

Bibliographic Details
Main Authors: Junet, Laila Kalidah, Abdul Majid, Zafri Azran, Sapuan, Abdul HaliM, Sayed, Inayatullah Shah, Pauzi, Nur Farahana
Format: Article
Language:English
English
Published: Institute of Physics Publishing (UK) 2014
Subjects:
Online Access:http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/1/JPCS_NSoMP_2014.pdf
http://irep.iium.edu.my/42084/3/42084_Multi-directiona_scopus.pdf
id iium-42084
recordtype eprints
spelling iium-420842017-09-21T10:18:57Z http://irep.iium.edu.my/42084/ Multi-directional radiation detector using photographic film Junet, Laila Kalidah Abdul Majid, Zafri Azran Sapuan, Abdul HaliM Sayed, Inayatullah Shah Pauzi, Nur Farahana QC Physics Ionising radiation has always been part of our surrounding and people are continuously exposed to it. Ionising radiation is harmful to human health, thus it is vital to monitor the radiation. To monitor radiation, there are three main points that should be observed cautiously, which are energy, quantity, and direction of the radiation sources. A three dimensional (3D) dosimeter is an example of a radiation detector that provide these three main points. This dosimeter is able to record the radiation dose distribution in 3D. Applying the concept of dose detection distribution, study has been done to design a multi-directional radiation detector of different filter thicknesses. This is obtained by designing a cylinder shaped aluminum filter with several layers of different thickness. Black and white photographic material is used as a radiation-sensitive material and a PVC material has been used as the enclosure. The device is then exposed to a radiation source with different exposure factors. For exposure factor 70 kVp, 16 mAs; the results have shown that optical density (OD) value at 135 degree is 1.86 higher compared with an OD value at 315 degree which is 0.71 as the 135 degree area received more radiation compare to 3150 region. Furthermore, with an evidence of different angle of film give different value of OD shows that this device has a multidirectional ability. Materials used to develop this device are widely available in the market, thus reducing the cost of development and making it suitable for commercialisation. Institute of Physics Publishing (UK) 2014 Article PeerReviewed application/pdf en http://irep.iium.edu.my/42084/1/JPCS_NSoMP_2014.pdf application/pdf en http://irep.iium.edu.my/42084/3/42084_Multi-directiona_scopus.pdf Junet, Laila Kalidah and Abdul Majid, Zafri Azran and Sapuan, Abdul HaliM and Sayed, Inayatullah Shah and Pauzi, Nur Farahana (2014) Multi-directional radiation detector using photographic film. Journal of Physics: Conference Series, 546 (1). pp. 1-6. ISSN 1742-6588 http://iopscience.iop.org/ doi:10.1088/1742-6596/546/1/012014
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic QC Physics
spellingShingle QC Physics
Junet, Laila Kalidah
Abdul Majid, Zafri Azran
Sapuan, Abdul HaliM
Sayed, Inayatullah Shah
Pauzi, Nur Farahana
Multi-directional radiation detector using photographic film
description Ionising radiation has always been part of our surrounding and people are continuously exposed to it. Ionising radiation is harmful to human health, thus it is vital to monitor the radiation. To monitor radiation, there are three main points that should be observed cautiously, which are energy, quantity, and direction of the radiation sources. A three dimensional (3D) dosimeter is an example of a radiation detector that provide these three main points. This dosimeter is able to record the radiation dose distribution in 3D. Applying the concept of dose detection distribution, study has been done to design a multi-directional radiation detector of different filter thicknesses. This is obtained by designing a cylinder shaped aluminum filter with several layers of different thickness. Black and white photographic material is used as a radiation-sensitive material and a PVC material has been used as the enclosure. The device is then exposed to a radiation source with different exposure factors. For exposure factor 70 kVp, 16 mAs; the results have shown that optical density (OD) value at 135 degree is 1.86 higher compared with an OD value at 315 degree which is 0.71 as the 135 degree area received more radiation compare to 3150 region. Furthermore, with an evidence of different angle of film give different value of OD shows that this device has a multidirectional ability. Materials used to develop this device are widely available in the market, thus reducing the cost of development and making it suitable for commercialisation.
format Article
author Junet, Laila Kalidah
Abdul Majid, Zafri Azran
Sapuan, Abdul HaliM
Sayed, Inayatullah Shah
Pauzi, Nur Farahana
author_facet Junet, Laila Kalidah
Abdul Majid, Zafri Azran
Sapuan, Abdul HaliM
Sayed, Inayatullah Shah
Pauzi, Nur Farahana
author_sort Junet, Laila Kalidah
title Multi-directional radiation detector using photographic film
title_short Multi-directional radiation detector using photographic film
title_full Multi-directional radiation detector using photographic film
title_fullStr Multi-directional radiation detector using photographic film
title_full_unstemmed Multi-directional radiation detector using photographic film
title_sort multi-directional radiation detector using photographic film
publisher Institute of Physics Publishing (UK)
publishDate 2014
url http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/
http://irep.iium.edu.my/42084/1/JPCS_NSoMP_2014.pdf
http://irep.iium.edu.my/42084/3/42084_Multi-directiona_scopus.pdf
first_indexed 2023-09-18T21:00:03Z
last_indexed 2023-09-18T21:00:03Z
_version_ 1777410563138125824