Wireless blood velocity spectra measurement system for healthcare evaluation: reference data
The aim of the present study was to determine the blood velocity and its indices in common carotid artery (CCA) as reference value for clinical and healthcare application using the constructed portable wireless Doppler blood flow velocimeter system. Evaluation of CCA blood velocity waveforms was per...
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2008
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/1/Wireless_blood_velocity_spectra_measurement_system_for_healthcare_evaluation.pdf |
id |
iium-44094 |
---|---|
recordtype |
eprints |
spelling |
iium-440942015-08-17T03:21:09Z http://irep.iium.edu.my/44094/ Wireless blood velocity spectra measurement system for healthcare evaluation: reference data Noor Azmi, Azran Azhim Akutagawa, Masatake Yoshizaki, Kazuo Obara, Shigeru Nomura, Masaharu Tanaka, Hiroyuki Yohsuke , Kinouchi TP248.13 Biotechnology The aim of the present study was to determine the blood velocity and its indices in common carotid artery (CCA) as reference value for clinical and healthcare application using the constructed portable wireless Doppler blood flow velocimeter system. Evaluation of CCA blood velocity waveforms was performed in 202 healthy volunteers in the age range of 20 to 69 years. Multivariate analysis was used to determine the relationship between the fixed factor and the outcome hemodynamic variables after adjustment for the related covariates. Results show a general age-related decrease in flow velocities and change in the velocity waveform. There is also a gender difference in velocity indices, except for peak systolic blood velocity. Gender difference is also found in systolic and pulse blood pressures. The findings suggest that waveform indices provide a more reliable evaluation of effects of aging and gender on CCA flow. In conclusion, normal CCA blood velocity parameters are determined in a total of 202 healthy volunteers between the third and seventh age decade after adjustment for gender and exercise effects. Findings may contribute to improved means of healthcare monitoring and clinical evaluation. IEEE 2008 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/44094/1/Wireless_blood_velocity_spectra_measurement_system_for_healthcare_evaluation.pdf Noor Azmi, Azran Azhim and Akutagawa, Masatake and Yoshizaki, Kazuo and Obara, Shigeru and Nomura, Masaharu and Tanaka, Hiroyuki and Yohsuke , Kinouchi (2008) Wireless blood velocity spectra measurement system for healthcare evaluation: reference data. In: 30th Annual International IEEE EMBS Conference, 20-25 Aug. 2008, Vancouver, BC. http://dx.doi.org/10.1109/IEMBS.2008.4649434 doi:10.1109/IEMBS.2008.4649434 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
TP248.13 Biotechnology |
spellingShingle |
TP248.13 Biotechnology Noor Azmi, Azran Azhim Akutagawa, Masatake Yoshizaki, Kazuo Obara, Shigeru Nomura, Masaharu Tanaka, Hiroyuki Yohsuke , Kinouchi Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
description |
The aim of the present study was to determine the blood velocity and its indices in common carotid artery (CCA) as reference value for clinical and healthcare application using the constructed portable wireless Doppler blood flow velocimeter system. Evaluation of CCA blood velocity waveforms was performed in 202 healthy volunteers in the age range of 20 to 69 years. Multivariate analysis was used to determine the relationship between the fixed factor and the outcome hemodynamic variables after adjustment for the related covariates. Results show a general age-related decrease in flow velocities and change in the velocity waveform. There is also a gender difference in velocity indices, except for peak systolic blood velocity. Gender difference is also found in systolic and pulse blood pressures. The findings suggest that waveform indices provide a more reliable evaluation of effects of aging and gender on CCA flow. In conclusion, normal CCA blood velocity parameters are determined in a total of 202 healthy volunteers between the third and seventh age decade after adjustment for gender and exercise effects. Findings may contribute to improved means of healthcare monitoring and clinical evaluation. |
format |
Conference or Workshop Item |
author |
Noor Azmi, Azran Azhim Akutagawa, Masatake Yoshizaki, Kazuo Obara, Shigeru Nomura, Masaharu Tanaka, Hiroyuki Yohsuke , Kinouchi |
author_facet |
Noor Azmi, Azran Azhim Akutagawa, Masatake Yoshizaki, Kazuo Obara, Shigeru Nomura, Masaharu Tanaka, Hiroyuki Yohsuke , Kinouchi |
author_sort |
Noor Azmi, Azran Azhim |
title |
Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
title_short |
Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
title_full |
Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
title_fullStr |
Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
title_full_unstemmed |
Wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
title_sort |
wireless blood velocity spectra measurement system for healthcare evaluation: reference data |
publisher |
IEEE |
publishDate |
2008 |
url |
http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/ http://irep.iium.edu.my/44094/1/Wireless_blood_velocity_spectra_measurement_system_for_healthcare_evaluation.pdf |
first_indexed |
2023-09-18T21:02:43Z |
last_indexed |
2023-09-18T21:02:43Z |
_version_ |
1777410731086446592 |