Tumor volume determination technique using pixel filling and discrete integral function
The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in medical equipment and increased computerization in many areas including medical field. This paper discusses a post segmentation tumor volume...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Engineering and Technology Publishing
2015
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/45768/ http://irep.iium.edu.my/45768/ http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf |
id |
iium-45768 |
---|---|
recordtype |
eprints |
spelling |
iium-457682018-01-05T04:11:59Z http://irep.iium.edu.my/45768/ Tumor volume determination technique using pixel filling and discrete integral function Aboaba, Abdulfattah A. Hameed, Shihab Ahmed Khalifa, Othman Omran Hassan Abdalla Hashim, Aisha Harun @ Haron, Rahmat Mohd Zain, Norzaini Rose RD Surgery TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in medical equipment and increased computerization in many areas including medical field. This paper discusses a post segmentation tumor volume determination technique that employs mainly pixel filling, and the application of discrete integral function to determine tumor volume. The prior steps taken involve finding pixel area resolution, image field of view (FOV), then FFT-Based interpolation to achieve smaller decimation of tumor area, and finally the use of discrete integral function (DIF) to accurately determine tumor volume. The result of the work will enhance the field of oncology in general, and image guided surgery (IGS) in particular. Engineering and Technology Publishing 2015-07 Article PeerReviewed application/pdf en http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf Aboaba, Abdulfattah A. and Hameed, Shihab Ahmed and Khalifa, Othman Omran and Hassan Abdalla Hashim, Aisha and Harun @ Haron, Rahmat and Mohd Zain, Norzaini Rose (2015) Tumor volume determination technique using pixel filling and discrete integral function. International Journal of Pharma Medicine and Biological Sciences, 4 (3). pp. 188-191. ISSN 2278-5221 http://www.ijpmbs.com/index.php?m=content&c=index&a=show&catid=132&id=169 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
RD Surgery TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices |
spellingShingle |
RD Surgery TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Aboaba, Abdulfattah A. Hameed, Shihab Ahmed Khalifa, Othman Omran Hassan Abdalla Hashim, Aisha Harun @ Haron, Rahmat Mohd Zain, Norzaini Rose Tumor volume determination technique using pixel filling and discrete integral function |
description |
The subject of tumor has generated lots of interest from the medical point of view and recently from engineering/research perspective owing to advancement in
medical equipment and increased computerization in many
areas including medical field. This paper discusses a post segmentation tumor volume determination technique that employs mainly pixel filling, and the application of discrete integral function to determine tumor volume. The prior steps taken involve finding pixel area resolution, image field of view (FOV), then FFT-Based interpolation to achieve smaller decimation of tumor area, and finally the use of discrete integral function (DIF) to accurately determine tumor volume. The result of the work will enhance the field of oncology in general, and image guided surgery (IGS) in particular. |
format |
Article |
author |
Aboaba, Abdulfattah A. Hameed, Shihab Ahmed Khalifa, Othman Omran Hassan Abdalla Hashim, Aisha Harun @ Haron, Rahmat Mohd Zain, Norzaini Rose |
author_facet |
Aboaba, Abdulfattah A. Hameed, Shihab Ahmed Khalifa, Othman Omran Hassan Abdalla Hashim, Aisha Harun @ Haron, Rahmat Mohd Zain, Norzaini Rose |
author_sort |
Aboaba, Abdulfattah A. |
title |
Tumor volume determination technique using pixel filling and discrete integral function |
title_short |
Tumor volume determination technique using pixel filling and discrete integral function |
title_full |
Tumor volume determination technique using pixel filling and discrete integral function |
title_fullStr |
Tumor volume determination technique using pixel filling and discrete integral function |
title_full_unstemmed |
Tumor volume determination technique using pixel filling and discrete integral function |
title_sort |
tumor volume determination technique using pixel filling and discrete integral function |
publisher |
Engineering and Technology Publishing |
publishDate |
2015 |
url |
http://irep.iium.edu.my/45768/ http://irep.iium.edu.my/45768/ http://irep.iium.edu.my/45768/1/Tumor_Volume_23-H2001-prof_shihab_2015.pdf |
first_indexed |
2023-09-18T21:05:09Z |
last_indexed |
2023-09-18T21:05:09Z |
_version_ |
1777410883372187648 |