The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray
Introduction: In medical imaging practice, the act of removing any clothes from the region of interest is justified as to prevent the presence of artefacts on radiographs. However, by doing so, the ‘aurah’ of the patients, especially for the Muslims, are not observed and can be considered as viol...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kulliyyah of Allied Health Sciences, International Islamic University Malaysia
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/47223/ http://irep.iium.edu.my/47223/ http://irep.iium.edu.my/47223/1/47223_The%20effect%20of%20different%20jubah%20dress%E2%80%99.pdf |
id |
iium-47223 |
---|---|
recordtype |
eprints |
spelling |
iium-472232019-07-12T08:52:42Z http://irep.iium.edu.my/47223/ The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray Amran, Umi Nadrah Mohd Rais, Nur Nadiah Q Science (General) RC71 Examination. Diagnosis Introduction: In medical imaging practice, the act of removing any clothes from the region of interest is justified as to prevent the presence of artefacts on radiographs. However, by doing so, the ‘aurah’ of the patients, especially for the Muslims, are not observed and can be considered as violating their privacy if they are not wellinformed beforehand. Previous studies have proved that radiographs with the presence of some fabric materials on the region of interest are radiographically acceptable. Therefore, the aims of this study are to tackle the issue of exposing one’s ‘aurah’ for a knee x-ray examination to take place and also to add insufficiency from the previous studies. Methods: The effect of three different jubah dress’ materials; heavy dull satin, high quality lycra and moss crepe on radiographic image quality for both anteroposterior (AP) and lateral knee x-ray examinations are evaluated. The effect on radiographic image quality by the manipulation of tube potentials on each jubah dress’ materials are also evaluated. A bovine’s knee is used to simulate human’s knee as opposed to previous studies which only utilized KYOTOKAGAKU phantom. Four experienced observers blindly graded image quality using Visual Grading Analysis (VGA). Results: This study shows that all three of the jubah dress’ materials produce no artefacts on images and at the same time, present no significant effect on radiographic image quality. The manipulation of tube potentials on each jubah dress’ materials also equally gives the same result. However, some increment to tube potentials is recommended to improve image quality. Conclusions: It can be concluded that a knee x-ray examination can be done without the need to remove either heavy dull satin, high quality lycra or moss crepe. Kulliyyah of Allied Health Sciences, International Islamic University Malaysia 2018-12-22 Article PeerReviewed application/pdf en http://irep.iium.edu.my/47223/1/47223_The%20effect%20of%20different%20jubah%20dress%E2%80%99.pdf Amran, Umi Nadrah and Mohd Rais, Nur Nadiah (2018) The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray. International Journal of Allied Health Sciences, 2 (2 Special issue: Media Imaging on the rise). pp. 292-303. ISSN 2600-8491 http://journals.iium.edu.my/ijahs/index.php/IJAHS/article/view/162 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
Q Science (General) RC71 Examination. Diagnosis |
spellingShingle |
Q Science (General) RC71 Examination. Diagnosis Amran, Umi Nadrah Mohd Rais, Nur Nadiah The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
description |
Introduction: In medical imaging practice, the act of removing any clothes from the
region of interest is justified as to prevent the presence of artefacts on radiographs.
However, by doing so, the ‘aurah’ of the patients, especially for the Muslims, are not
observed and can be considered as violating their privacy if they are not wellinformed beforehand. Previous studies have proved that radiographs with the
presence of some fabric materials on the region of interest are radiographically
acceptable. Therefore, the aims of this study are to tackle the issue of exposing one’s
‘aurah’ for a knee x-ray examination to take place and also to add insufficiency from
the previous studies. Methods: The effect of three different jubah dress’ materials;
heavy dull satin, high quality lycra and moss crepe on radiographic image quality for
both anteroposterior (AP) and lateral knee x-ray examinations are evaluated. The
effect on radiographic image quality by the manipulation of tube potentials on each
jubah dress’ materials are also evaluated. A bovine’s knee is used to simulate human’s
knee as opposed to previous studies which only utilized KYOTOKAGAKU phantom.
Four experienced observers blindly graded image quality using Visual Grading
Analysis (VGA). Results: This study shows that all three of the jubah dress’ materials
produce no artefacts on images and at the same time, present no significant effect on
radiographic image quality. The manipulation of tube potentials on each jubah dress’
materials also equally gives the same result. However, some increment to tube
potentials is recommended to improve image quality. Conclusions: It can be
concluded that a knee x-ray examination can be done without the need to remove
either heavy dull satin, high quality lycra or moss crepe. |
format |
Article |
author |
Amran, Umi Nadrah Mohd Rais, Nur Nadiah |
author_facet |
Amran, Umi Nadrah Mohd Rais, Nur Nadiah |
author_sort |
Amran, Umi Nadrah |
title |
The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
title_short |
The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
title_full |
The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
title_fullStr |
The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
title_full_unstemmed |
The effect of different jubah dress’ materials on image quality using computed radiography (CR) on knee X-ray |
title_sort |
effect of different jubah dress’ materials on image quality using computed radiography (cr) on knee x-ray |
publisher |
Kulliyyah of Allied Health Sciences, International Islamic University Malaysia |
publishDate |
2018 |
url |
http://irep.iium.edu.my/47223/ http://irep.iium.edu.my/47223/ http://irep.iium.edu.my/47223/1/47223_The%20effect%20of%20different%20jubah%20dress%E2%80%99.pdf |
first_indexed |
2023-09-18T21:07:13Z |
last_indexed |
2023-09-18T21:07:13Z |
_version_ |
1777411013232033792 |