A framework for non-contact ECG signal detection device on smart chair and its implementation
Heart disease is the top cause of death in Malaysia. Arrhythmia is a sign of heart diseases that entails abnormal heart rhythm and is detected mostly by electrocardiogram (ECG) devices, which are attached to the chest, arms or legs of an individual. This mostly requires contact with the skin, whi...
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English English |
Published: |
2015
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/48398/ http://irep.iium.edu.my/48398/ http://irep.iium.edu.my/48398/8/dr_rizal.pdf http://irep.iium.edu.my/48398/2/Book_Schedule.pdf http://irep.iium.edu.my/48398/1/DaEng_2015_Submission_70.pdf |
id |
iium-48398 |
---|---|
recordtype |
eprints |
spelling |
iium-483982016-01-14T08:27:43Z http://irep.iium.edu.my/48398/ A framework for non-contact ECG signal detection device on smart chair and its implementation Wali, Tuerxun Mohd. Nor, Rizal Sidek, Khairul Azami Abubakar, Adamu Chiroma, Haruna Herawan, Tutut QA75 Electronic computers. Computer science Heart disease is the top cause of death in Malaysia. Arrhythmia is a sign of heart diseases that entails abnormal heart rhythm and is detected mostly by electrocardiogram (ECG) devices, which are attached to the chest, arms or legs of an individual. This mostly requires contact with the skin, which has to be routinely examined. Unfortunately, in unexpected, extreme situations of rising symptoms related to heart problems, the time it takes to examine a situation with the ECG signal device might make the difference between life and death. Non-contact ECG signal detection techniques could help assess cases of heart problems or an initial apoplectic condition without attaching ECG signal devices to people’s body. This paper aims to provide a non-contact ECG signal detection framework that could empower Malaysian community to get an access to understanding arrhythmic phase status at any time of their activities. The framework relies on one of the major activities that humans often engage in, which is sitting. As a result, a non-contact ECG signal device is conceptualized for chairs that most people can use at home, in the office chair and many other sitting situations. 2015-04-25 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/48398/8/dr_rizal.pdf application/pdf en http://irep.iium.edu.my/48398/2/Book_Schedule.pdf application/pdf en http://irep.iium.edu.my/48398/1/DaEng_2015_Submission_70.pdf Wali, Tuerxun and Mohd. Nor, Rizal and Sidek, Khairul Azami and Abubakar, Adamu and Chiroma, Haruna and Herawan, Tutut (2015) A framework for non-contact ECG signal detection device on smart chair and its implementation. In: Second International Conference on Advanced Data and Information Engineering (DaEng-2015), 25th April 2015 - 26th April 2015, Bali, Indonesia. (Unpublished) http://daeng2015.amcs.co/ |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English English |
topic |
QA75 Electronic computers. Computer science |
spellingShingle |
QA75 Electronic computers. Computer science Wali, Tuerxun Mohd. Nor, Rizal Sidek, Khairul Azami Abubakar, Adamu Chiroma, Haruna Herawan, Tutut A framework for non-contact ECG signal detection device on smart chair and its implementation |
description |
Heart disease is the top cause of death in Malaysia. Arrhythmia is a sign of heart diseases
that entails abnormal heart rhythm and is detected mostly by electrocardiogram (ECG) devices,
which are attached to the chest, arms or legs of an individual. This mostly requires contact with the
skin, which has to be routinely examined. Unfortunately, in unexpected, extreme situations of rising
symptoms related to heart problems, the time it takes to examine a situation with the ECG signal
device might make the difference between life and death. Non-contact ECG signal detection
techniques could help assess cases of heart problems or an initial apoplectic condition without
attaching ECG signal devices to people’s body. This paper aims to provide a non-contact ECG
signal detection framework that could empower Malaysian community to get an access to
understanding arrhythmic phase status at any time of their activities. The framework relies on one of
the major activities that humans often engage in, which is sitting. As a result, a non-contact ECG
signal device is conceptualized for chairs that most people can use at home, in the office chair and
many other sitting situations. |
format |
Conference or Workshop Item |
author |
Wali, Tuerxun Mohd. Nor, Rizal Sidek, Khairul Azami Abubakar, Adamu Chiroma, Haruna Herawan, Tutut |
author_facet |
Wali, Tuerxun Mohd. Nor, Rizal Sidek, Khairul Azami Abubakar, Adamu Chiroma, Haruna Herawan, Tutut |
author_sort |
Wali, Tuerxun |
title |
A framework for non-contact ECG signal detection device on smart chair and its implementation |
title_short |
A framework for non-contact ECG signal detection device on smart chair and its implementation |
title_full |
A framework for non-contact ECG signal detection device on smart chair and its implementation |
title_fullStr |
A framework for non-contact ECG signal detection device on smart chair and its implementation |
title_full_unstemmed |
A framework for non-contact ECG signal detection device on smart chair and its implementation |
title_sort |
framework for non-contact ecg signal detection device on smart chair and its implementation |
publishDate |
2015 |
url |
http://irep.iium.edu.my/48398/ http://irep.iium.edu.my/48398/ http://irep.iium.edu.my/48398/8/dr_rizal.pdf http://irep.iium.edu.my/48398/2/Book_Schedule.pdf http://irep.iium.edu.my/48398/1/DaEng_2015_Submission_70.pdf |
first_indexed |
2023-09-18T21:08:40Z |
last_indexed |
2023-09-18T21:08:40Z |
_version_ |
1777411104905887744 |