Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds

This study attempted to examine the feasibility of using medical Computerized Tomography (CT) imaging scanner to monitor the growth of tissue engineered constructs (TECs) in vitro. A preliminary CT examination was performed on TECs prepared from serially expanded chondrocytes seeded on poly (lacti...

Full description

Bibliographic Details
Main Authors: Mat Nawi, Nur Farhana, Zainuddin, Zainul Ibrahim, Md Nazir, Noorhidayah, Mohamad, Mohd Yusof, Ahmad Radzi, Muhammad Aa’zamuddin, Hashim, Rosyafirah, Sha’ban, Munirah
Format: Conference or Workshop Item
Language:English
Published: Kulliyah of Engineering, International Islamic University Malaysia 2016
Subjects:
Online Access:http://irep.iium.edu.my/51668/
http://irep.iium.edu.my/51668/1/51668.pdf
id iium-51668
recordtype eprints
spelling iium-516682016-08-18T01:40:21Z http://irep.iium.edu.my/51668/ Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds Mat Nawi, Nur Farhana Zainuddin, Zainul Ibrahim Md Nazir, Noorhidayah Mohamad, Mohd Yusof Ahmad Radzi, Muhammad Aa’zamuddin Hashim, Rosyafirah Sha’ban, Munirah TP248.13 Biotechnology This study attempted to examine the feasibility of using medical Computerized Tomography (CT) imaging scanner to monitor the growth of tissue engineered constructs (TECs) in vitro. A preliminary CT examination was performed on TECs prepared from serially expanded chondrocytes seeded on poly (lactic-co-glycolic acid) (PLGA) based scaffolds that acted as cell carriers. One day old PLGA with fibrin and cells (PFC), PLGA and cells (PC) as well as PLGA with Fibrin (PF) constructs were stored in normal saline prior to CT examination. The kVp used was 80 Kvpwhile the effective mAs was 11 mAs. Sharp kernel was chosen as the reconstruction parameters and slice thickness used was 0.1mm.A PLGA without cells or fibrin was used as control. X-ray attenuation of TECs, measured in Hounsfield units (HU) or, also known as CT values were observed. The results indicated that the control PLGA, the PFC, the PC and also the PF constructs gave CT values between -665HU to 477HU, between 149HU to 181HU, between -120HU to 263HU and -209HU to 185HU respectively. These initial results indicate that the x-ray absorption-based quantitative differentiation between TECs could be appreciated. The CT values documented suggest that the differences in attenuation values are dependent on the condition of the scaffolds or the TECs themselves. Furthermore, the use of intravascular ultrasound (IVUS) software installed in the CT system was found to be useful in appreciating the different compositions within the scanned samples. It is hoped that the outcomes of this preliminary study can serve as a baseline for future research to look for an alternative method to quantitatively monitor the growth of TECs in vitro as well as in vivo. Kulliyah of Engineering, International Islamic University Malaysia 2016 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/51668/1/51668.pdf Mat Nawi, Nur Farhana and Zainuddin, Zainul Ibrahim and Md Nazir, Noorhidayah and Mohamad, Mohd Yusof and Ahmad Radzi, Muhammad Aa’zamuddin and Hashim, Rosyafirah and Sha’ban, Munirah (2016) Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds. In: 4th International Conference on Biotechnology Engineering 2016 (ICBioE 2016), 25th-27th July 2016, Kuala Lumpur.
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic TP248.13 Biotechnology
spellingShingle TP248.13 Biotechnology
Mat Nawi, Nur Farhana
Zainuddin, Zainul Ibrahim
Md Nazir, Noorhidayah
Mohamad, Mohd Yusof
Ahmad Radzi, Muhammad Aa’zamuddin
Hashim, Rosyafirah
Sha’ban, Munirah
Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
description This study attempted to examine the feasibility of using medical Computerized Tomography (CT) imaging scanner to monitor the growth of tissue engineered constructs (TECs) in vitro. A preliminary CT examination was performed on TECs prepared from serially expanded chondrocytes seeded on poly (lactic-co-glycolic acid) (PLGA) based scaffolds that acted as cell carriers. One day old PLGA with fibrin and cells (PFC), PLGA and cells (PC) as well as PLGA with Fibrin (PF) constructs were stored in normal saline prior to CT examination. The kVp used was 80 Kvpwhile the effective mAs was 11 mAs. Sharp kernel was chosen as the reconstruction parameters and slice thickness used was 0.1mm.A PLGA without cells or fibrin was used as control. X-ray attenuation of TECs, measured in Hounsfield units (HU) or, also known as CT values were observed. The results indicated that the control PLGA, the PFC, the PC and also the PF constructs gave CT values between -665HU to 477HU, between 149HU to 181HU, between -120HU to 263HU and -209HU to 185HU respectively. These initial results indicate that the x-ray absorption-based quantitative differentiation between TECs could be appreciated. The CT values documented suggest that the differences in attenuation values are dependent on the condition of the scaffolds or the TECs themselves. Furthermore, the use of intravascular ultrasound (IVUS) software installed in the CT system was found to be useful in appreciating the different compositions within the scanned samples. It is hoped that the outcomes of this preliminary study can serve as a baseline for future research to look for an alternative method to quantitatively monitor the growth of TECs in vitro as well as in vivo.
format Conference or Workshop Item
author Mat Nawi, Nur Farhana
Zainuddin, Zainul Ibrahim
Md Nazir, Noorhidayah
Mohamad, Mohd Yusof
Ahmad Radzi, Muhammad Aa’zamuddin
Hashim, Rosyafirah
Sha’ban, Munirah
author_facet Mat Nawi, Nur Farhana
Zainuddin, Zainul Ibrahim
Md Nazir, Noorhidayah
Mohamad, Mohd Yusof
Ahmad Radzi, Muhammad Aa’zamuddin
Hashim, Rosyafirah
Sha’ban, Munirah
author_sort Mat Nawi, Nur Farhana
title Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
title_short Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
title_full Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
title_fullStr Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
title_full_unstemmed Exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on Poly(Lactic-co-Glycolic Acid) based scaffolds
title_sort exploring the feasibility in using medical computerized tomography to monitor growth progression in tissue engineered construct prepared from cells seeded on poly(lactic-co-glycolic acid) based scaffolds
publisher Kulliyah of Engineering, International Islamic University Malaysia
publishDate 2016
url http://irep.iium.edu.my/51668/
http://irep.iium.edu.my/51668/1/51668.pdf
first_indexed 2023-09-18T21:13:11Z
last_indexed 2023-09-18T21:13:11Z
_version_ 1777411389254533120