Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon
Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but...
Main Author: | |
---|---|
Format: | Article |
Language: | English |
Published: |
Polish Cardiac Society
2009
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/5200/ http://irep.iium.edu.my/5200/ http://irep.iium.edu.my/5200/1/Stent_Dislodgement_cario_Polska.pdf |
id |
iium-5200 |
---|---|
recordtype |
eprints |
spelling |
iium-52002011-11-04T02:46:38Z http://irep.iium.edu.my/5200/ Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon Ngow, Harris Abdullah RC Internal medicine Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the proximal left anterior descending (LAD) coronary artery prior to deployment. This patient however was successfully treated with re-wiring of the artery with two parallel wires and the stent’s reposition prior to deployment with the help of a small balloon. Polish Cardiac Society 2009 Article PeerReviewed application/pdf en http://irep.iium.edu.my/5200/1/Stent_Dislodgement_cario_Polska.pdf Ngow, Harris Abdullah (2009) Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon. Kardiologia Polska, 67 (9). pp. 1040-1042. ISSN 0022-9032 http://www.kardiologiapolska.pl/ |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
RC Internal medicine |
spellingShingle |
RC Internal medicine Ngow, Harris Abdullah Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon |
description |
Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the proximal left anterior descending (LAD) coronary artery prior to deployment. This patient however was successfully
treated with re-wiring of the artery with two parallel wires and the stent’s reposition prior to deployment with the help of a small balloon. |
format |
Article |
author |
Ngow, Harris Abdullah |
author_facet |
Ngow, Harris Abdullah |
author_sort |
Ngow, Harris Abdullah |
title |
Stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
title_short |
Stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
title_full |
Stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
title_fullStr |
Stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
title_full_unstemmed |
Stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
title_sort |
stent dislodgement in left anterior descending coronary
artery and successful deployment with two parallel wires
and a small balloon |
publisher |
Polish Cardiac Society |
publishDate |
2009 |
url |
http://irep.iium.edu.my/5200/ http://irep.iium.edu.my/5200/ http://irep.iium.edu.my/5200/1/Stent_Dislodgement_cario_Polska.pdf |
first_indexed |
2023-09-18T20:13:41Z |
last_indexed |
2023-09-18T20:13:41Z |
_version_ |
1777407645860233216 |