15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan

Introduction: Gastrocnemius flap is the workhorse for wound coverage in the proximal tibia. It can be perform by general orthopaedic surgeon because it is done without the need of microscopic instrumentation. Its coverage can be extended to cover the knee and midshaft of tibia when skin overlying...

Full description

Bibliographic Details
Main Author: Mohd Yusof, Nazri
Format: Article
Language:English
Published: Kulliyyah of Medicine, International Islamic University Malaysia 2017
Subjects:
Online Access:http://irep.iium.edu.my/58376/
http://irep.iium.edu.my/58376/
http://irep.iium.edu.my/58376/1/Abstract-Book-for-IMJM-gastrocnemius%20flap.pdf
id iium-58376
recordtype eprints
spelling iium-583762017-11-01T04:37:26Z http://irep.iium.edu.my/58376/ 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan Mohd Yusof, Nazri RD701 Orthopedics Introduction: Gastrocnemius flap is the workhorse for wound coverage in the proximal tibia. It can be perform by general orthopaedic surgeon because it is done without the need of microscopic instrumentation. Its coverage can be extended to cover the knee and midshaft of tibia when skin overlying it is included in the flap. Materials and method: From July 2002 till January 2017, 47 patients underwent gastrocnemius flap in our hospital (26 muscular and 21 musculocutaneous flap). 41 flaps were raised from medial, 5 lateral and 1 from both muscle belly. There were 41 males and 6 females with the mean age of 21.4 years old (range 13-82). The flaps were done to cover upper third (29), upper half (6), midshaft tibia (6), knee (2) and distal femur (1). The initial problems were open fracture (30), infection following plating (9), necrotising fasciitis (4), degloving injury (2), pin site infection (1) and melioidosis (1). Eight patients have underlying Diabetes mellitus, 2 Hepatitis B, 3 HIV or 1 COAD. Two patients have sciatic nerve palsy. Results: There was no flap necrosis. Complications include persistence infection in 6 patients which require repeated debridement (5), below knee amputation (1), advancement of flap (1) and additional fasciocutaneous flap (1). Two patients with gastrocnemius musculocutaneous flap had partial failure of skin graft that heals with dressing. One patient develops transient peroneal nerve palsy following the lateral gastrocnemius transfer. Conclusion: Gastrocnemius flap is a reliable and safe procedure in orthopaedic surgery. Problems that occur are associated with inadequate debridement and underestimate the size of the flap. Kulliyyah of Medicine, International Islamic University Malaysia 2017-09 Article PeerReviewed application/pdf en http://irep.iium.edu.my/58376/1/Abstract-Book-for-IMJM-gastrocnemius%20flap.pdf Mohd Yusof, Nazri (2017) 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan. International Medical Journal Malaysia (IMJM), 16 (S1). p. 10. E-ISSN 1823-4631 http://iiumedic.net/imjm/v1/about-imjm/
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
topic RD701 Orthopedics
spellingShingle RD701 Orthopedics
Mohd Yusof, Nazri
15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
description Introduction: Gastrocnemius flap is the workhorse for wound coverage in the proximal tibia. It can be perform by general orthopaedic surgeon because it is done without the need of microscopic instrumentation. Its coverage can be extended to cover the knee and midshaft of tibia when skin overlying it is included in the flap. Materials and method: From July 2002 till January 2017, 47 patients underwent gastrocnemius flap in our hospital (26 muscular and 21 musculocutaneous flap). 41 flaps were raised from medial, 5 lateral and 1 from both muscle belly. There were 41 males and 6 females with the mean age of 21.4 years old (range 13-82). The flaps were done to cover upper third (29), upper half (6), midshaft tibia (6), knee (2) and distal femur (1). The initial problems were open fracture (30), infection following plating (9), necrotising fasciitis (4), degloving injury (2), pin site infection (1) and melioidosis (1). Eight patients have underlying Diabetes mellitus, 2 Hepatitis B, 3 HIV or 1 COAD. Two patients have sciatic nerve palsy. Results: There was no flap necrosis. Complications include persistence infection in 6 patients which require repeated debridement (5), below knee amputation (1), advancement of flap (1) and additional fasciocutaneous flap (1). Two patients with gastrocnemius musculocutaneous flap had partial failure of skin graft that heals with dressing. One patient develops transient peroneal nerve palsy following the lateral gastrocnemius transfer. Conclusion: Gastrocnemius flap is a reliable and safe procedure in orthopaedic surgery. Problems that occur are associated with inadequate debridement and underestimate the size of the flap.
format Article
author Mohd Yusof, Nazri
author_facet Mohd Yusof, Nazri
author_sort Mohd Yusof, Nazri
title 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
title_short 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
title_full 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
title_fullStr 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
title_full_unstemmed 15 years review of gastrocnemius flap done in Department Of Orthopaedics, Hospital Tengku Ampuan Afzan, Kuantan
title_sort 15 years review of gastrocnemius flap done in department of orthopaedics, hospital tengku ampuan afzan, kuantan
publisher Kulliyyah of Medicine, International Islamic University Malaysia
publishDate 2017
url http://irep.iium.edu.my/58376/
http://irep.iium.edu.my/58376/
http://irep.iium.edu.my/58376/1/Abstract-Book-for-IMJM-gastrocnemius%20flap.pdf
first_indexed 2023-09-18T21:22:32Z
last_indexed 2023-09-18T21:22:32Z
_version_ 1777411977647226880