Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique
Multilevel inverters controlled suffers from the issue of harmonic distortion in the output voltage. Selective Harmonic Elimination (SHE) technique plays an effective role to eliminate these harmonics. The undesirable odd harmonics can be eliminated by having optimized the switching angles in S...
Main Authors: | , , , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English English |
Published: |
IEEE
2018
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/67991/ http://irep.iium.edu.my/67991/ http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf |
id |
iium-67991 |
---|---|
recordtype |
eprints |
spelling |
iium-679912019-08-17T04:30:19Z http://irep.iium.edu.my/67991/ Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique Aboadla, Ezzidin Hassan Elmabrouk Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Yaacob, Mashkuri Aboadla, Ali Khalil, Ashraf F. Muhaisen, Naser TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Multilevel inverters controlled suffers from the issue of harmonic distortion in the output voltage. Selective Harmonic Elimination (SHE) technique plays an effective role to eliminate these harmonics. The undesirable odd harmonics can be eliminated by having optimized the switching angles in SHE signal. To optimized and obtained these switching angles, a number of nonlinear equations should be solved using a numerical method. In addition to the modulation index, by changing the value of the duty cycle the Total Harmonics Distortion (THD) will also change. In this paper, a novel Optimization Harmonic Elimination Technique (OHET) based on SHE scheme is proposed in order to minimize Total Harmonic Distortion (THD). To evaluate and investigate the performance of the proposed scheme, a seven-level cascaded inverter is simulated by MATLAB and PSIM software. IEEE 2018-09-19 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf application/pdf en http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf Aboadla, Ezzidin Hassan Elmabrouk and Khan, Sheroz and Habaebi, Mohamed Hadi and Gunawan, Teddy Surya and Hamida, Belal Ahmed and Yaacob, Mashkuri and Aboadla, Ali and Khalil, Ashraf F. and Muhaisen, Naser (2018) Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique. In: 2018 7th International Conference on Computer Communication Engineering (ICCCE2018), 19-20 September 2018, Kuala Lumpur. https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=8539330&tag=1 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English English |
topic |
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices |
spellingShingle |
TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Aboadla, Ezzidin Hassan Elmabrouk Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Yaacob, Mashkuri Aboadla, Ali Khalil, Ashraf F. Muhaisen, Naser Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
description |
Multilevel inverters controlled suffers from the
issue of harmonic distortion in the output voltage. Selective
Harmonic Elimination (SHE) technique plays an effective role
to eliminate these harmonics. The undesirable odd harmonics
can be eliminated by having optimized the switching angles in
SHE signal. To optimized and obtained these switching angles,
a number of nonlinear equations should be solved using a
numerical method. In addition to the modulation index, by
changing the value of the duty cycle the Total Harmonics
Distortion (THD) will also change. In this paper, a novel
Optimization Harmonic Elimination Technique (OHET) based
on SHE scheme is proposed in order to minimize Total
Harmonic Distortion (THD). To evaluate and investigate the
performance of the proposed scheme, a seven-level cascaded
inverter is simulated by MATLAB and PSIM software. |
format |
Conference or Workshop Item |
author |
Aboadla, Ezzidin Hassan Elmabrouk Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Yaacob, Mashkuri Aboadla, Ali Khalil, Ashraf F. Muhaisen, Naser |
author_facet |
Aboadla, Ezzidin Hassan Elmabrouk Khan, Sheroz Habaebi, Mohamed Hadi Gunawan, Teddy Surya Hamida, Belal Ahmed Yaacob, Mashkuri Aboadla, Ali Khalil, Ashraf F. Muhaisen, Naser |
author_sort |
Aboadla, Ezzidin Hassan Elmabrouk |
title |
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
title_short |
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
title_full |
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
title_fullStr |
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
title_full_unstemmed |
Effect of duty cycle on THD for multilevel inverter based on selective harmonic elimination technique |
title_sort |
effect of duty cycle on thd for multilevel inverter based on selective harmonic elimination technique |
publisher |
IEEE |
publishDate |
2018 |
url |
http://irep.iium.edu.my/67991/ http://irep.iium.edu.my/67991/ http://irep.iium.edu.my/67991/1/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_article.pdf http://irep.iium.edu.my/67991/2/67991_Effect%20of%20Duty%20Cycle%20on%20THD%20for%20Multilevel%20Inverter%20_Scopus.pdf |
first_indexed |
2023-09-18T21:36:32Z |
last_indexed |
2023-09-18T21:36:32Z |
_version_ |
1777412857786269696 |