Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method

Diabetes has shown to be a chronic disease world over, mainly caused due to reduced physical activity and increased obesity. World health organization statistics show diabetes as a leading cause of disability universally. To avoid extreme medical conditions of subjects, regular monitoring of their g...

Full description

Bibliographic Details
Main Authors: Zaharudin, Zarimin, Mohd Mansor, Ahmad Fairuzabadi, Zainuddin, Ahmad Anwar, Adam, Ismail, Khan, Sheroz, Nordin, Anis Nurashikin, Shaikh, Faraz Ahmed, Abdul Kader, Kushsairy, Hamida, Belal Ahmed
Format: Article
Language:English
English
Published: Universiti Teknikal Malaysia Melaka 2020
Subjects:
Online Access:http://irep.iium.edu.my/76501/
http://irep.iium.edu.my/76501/
http://irep.iium.edu.my/76501/1/UNITENRevisedSheroz3%20ZARIMIN%20%28UNITEN-PAPER%20WITH%20ACCEPTANCE%20AND%20INVOICE%29.pdf
http://irep.iium.edu.my/76501/2/Accept_paper_zarimin.pdf
id iium-76501
recordtype eprints
spelling iium-765012019-11-25T07:55:10Z http://irep.iium.edu.my/76501/ Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method Zaharudin, Zarimin Mohd Mansor, Ahmad Fairuzabadi Zainuddin, Ahmad Anwar Adam, Ismail Khan, Sheroz Nordin, Anis Nurashikin Shaikh, Faraz Ahmed Abdul Kader, Kushsairy Hamida, Belal Ahmed TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices Diabetes has shown to be a chronic disease world over, mainly caused due to reduced physical activity and increased obesity. World health organization statistics show diabetes as a leading cause of disability universally. To avoid extreme medical conditions of subjects, regular monitoring of their glucose levels has been suggested. The most common method that has been in use is the pinprick method for glucose monitoring which carries the risk of contamination as well as irritation. One possible approach called noninvasive technique can be adopted to avoid this major concern. This paper presents designing Inter-Digital-Sensor (IDS) for non-invasive sensing of the glucose level. The sensor-based chip once mounted onto the upper arm or pinkie finger of diabetes subject, is able to sense different glucose levels concentration as impedance plots. A set of several simulation results has been obtained using COMSOL for getting optimized dimensions of the sensor digits. This research has presented the generation of an electric field and intensity by using electrode of known length with element spacing varying from 250µm to 600µm developed over 15mm x 20mm sensor area. An IDS of 475µm width spacing with ten (10) digits producing 2.33 pF of capacitance value with impedance resonating at 13 GHz of frequency is reported in this paper. Universiti Teknikal Malaysia Melaka 2020-02 Article PeerReviewed application/pdf en http://irep.iium.edu.my/76501/1/UNITENRevisedSheroz3%20ZARIMIN%20%28UNITEN-PAPER%20WITH%20ACCEPTANCE%20AND%20INVOICE%29.pdf application/pdf en http://irep.iium.edu.my/76501/2/Accept_paper_zarimin.pdf Zaharudin, Zarimin and Mohd Mansor, Ahmad Fairuzabadi and Zainuddin, Ahmad Anwar and Adam, Ismail and Khan, Sheroz and Nordin, Anis Nurashikin and Shaikh, Faraz Ahmed and Abdul Kader, Kushsairy and Hamida, Belal Ahmed (2020) Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method. Journal of Advanced Manufacturing Technology, 14 (1). pp. 1-9. ISSN 1985-3157 E-ISSN 2289-8107 (In Press) http://journal.utem.edu.my/index.php/jamt
repository_type Digital Repository
institution_category Local University
institution International Islamic University Malaysia
building IIUM Repository
collection Online Access
language English
English
topic TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
spellingShingle TK7800 Electronics. Computer engineering. Computer hardware. Photoelectronic devices
Zaharudin, Zarimin
Mohd Mansor, Ahmad Fairuzabadi
Zainuddin, Ahmad Anwar
Adam, Ismail
Khan, Sheroz
Nordin, Anis Nurashikin
Shaikh, Faraz Ahmed
Abdul Kader, Kushsairy
Hamida, Belal Ahmed
Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
description Diabetes has shown to be a chronic disease world over, mainly caused due to reduced physical activity and increased obesity. World health organization statistics show diabetes as a leading cause of disability universally. To avoid extreme medical conditions of subjects, regular monitoring of their glucose levels has been suggested. The most common method that has been in use is the pinprick method for glucose monitoring which carries the risk of contamination as well as irritation. One possible approach called noninvasive technique can be adopted to avoid this major concern. This paper presents designing Inter-Digital-Sensor (IDS) for non-invasive sensing of the glucose level. The sensor-based chip once mounted onto the upper arm or pinkie finger of diabetes subject, is able to sense different glucose levels concentration as impedance plots. A set of several simulation results has been obtained using COMSOL for getting optimized dimensions of the sensor digits. This research has presented the generation of an electric field and intensity by using electrode of known length with element spacing varying from 250µm to 600µm developed over 15mm x 20mm sensor area. An IDS of 475µm width spacing with ten (10) digits producing 2.33 pF of capacitance value with impedance resonating at 13 GHz of frequency is reported in this paper.
format Article
author Zaharudin, Zarimin
Mohd Mansor, Ahmad Fairuzabadi
Zainuddin, Ahmad Anwar
Adam, Ismail
Khan, Sheroz
Nordin, Anis Nurashikin
Shaikh, Faraz Ahmed
Abdul Kader, Kushsairy
Hamida, Belal Ahmed
author_facet Zaharudin, Zarimin
Mohd Mansor, Ahmad Fairuzabadi
Zainuddin, Ahmad Anwar
Adam, Ismail
Khan, Sheroz
Nordin, Anis Nurashikin
Shaikh, Faraz Ahmed
Abdul Kader, Kushsairy
Hamida, Belal Ahmed
author_sort Zaharudin, Zarimin
title Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
title_short Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
title_full Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
title_fullStr Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
title_full_unstemmed Design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
title_sort design and dimensional analysis of interdigital sensor for blood glucose measurement through non-invasive method
publisher Universiti Teknikal Malaysia Melaka
publishDate 2020
url http://irep.iium.edu.my/76501/
http://irep.iium.edu.my/76501/
http://irep.iium.edu.my/76501/1/UNITENRevisedSheroz3%20ZARIMIN%20%28UNITEN-PAPER%20WITH%20ACCEPTANCE%20AND%20INVOICE%29.pdf
http://irep.iium.edu.my/76501/2/Accept_paper_zarimin.pdf
first_indexed 2023-09-18T21:48:04Z
last_indexed 2023-09-18T21:48:04Z
_version_ 1777413584127524864