An experimental study on spray filled tower
This paper deals with an experimental study of different parameters in a Spray Filled Tower. The pressure drop and drift loss characteristics of cellular type drift eliminators and also those made of wood and cement-asbestos were experimentally investigated. Air distribution at some specific points...
Main Author: | |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2002
|
Subjects: | |
Online Access: | http://irep.iium.edu.my/8228/ http://irep.iium.edu.my/8228/1/BSME-ASME2002.pdf |
id |
iium-8228 |
---|---|
recordtype |
eprints |
spelling |
iium-82282013-05-14T06:43:47Z http://irep.iium.edu.my/8228/ An experimental study on spray filled tower Mohiuddin, A. K. M. T Technology (General) This paper deals with an experimental study of different parameters in a Spray Filled Tower. The pressure drop and drift loss characteristics of cellular type drift eliminators and also those made of wood and cement-asbestos were experimentally investigated. Air distribution at some specific points within the tower was also investigated. The experiments were conducted with two and three stages of both wooden drift eliminators (WDE) and cement-asbestos drift eliminators (CADE) with various orientation angle, of the eliminator plates. But for cellular type drift eliminators (CTDE) the experiment was carried out with one, two and three stages. The results showed that the pressure drop and drift loss were strong functions of number of stages, n and air flow rate. In case of WDE and CADE they were strongly dependent on as well. 2002-01 Conference or Workshop Item PeerReviewed application/pdf en http://irep.iium.edu.my/8228/1/BSME-ASME2002.pdf Mohiuddin, A. K. M. (2002) An experimental study on spray filled tower. In: BSME-ASME International Conference on Thermal Engineering, 31 December 2001 - 2 January 2002, Dhaka, Bangladesh. |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
International Islamic University Malaysia |
building |
IIUM Repository |
collection |
Online Access |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Mohiuddin, A. K. M. An experimental study on spray filled tower |
description |
This paper deals with an experimental study of different parameters in a Spray Filled Tower. The pressure drop and drift loss characteristics of cellular type drift eliminators and also those made of wood and cement-asbestos were experimentally investigated. Air distribution at some specific points within the tower was also investigated. The experiments were conducted with two and three stages of both wooden drift eliminators (WDE) and cement-asbestos drift eliminators (CADE) with various orientation angle, of the eliminator plates. But for cellular type drift eliminators (CTDE) the experiment was carried out with one, two and three stages. The results showed that the pressure drop and drift loss were strong functions of number of stages, n and air flow rate. In case of WDE and CADE they were strongly dependent on as well. |
format |
Conference or Workshop Item |
author |
Mohiuddin, A. K. M. |
author_facet |
Mohiuddin, A. K. M. |
author_sort |
Mohiuddin, A. K. M. |
title |
An experimental study on spray filled tower |
title_short |
An experimental study on spray filled tower |
title_full |
An experimental study on spray filled tower |
title_fullStr |
An experimental study on spray filled tower |
title_full_unstemmed |
An experimental study on spray filled tower |
title_sort |
experimental study on spray filled tower |
publishDate |
2002 |
url |
http://irep.iium.edu.my/8228/ http://irep.iium.edu.my/8228/1/BSME-ASME2002.pdf |
first_indexed |
2023-09-18T20:17:53Z |
last_indexed |
2023-09-18T20:17:53Z |
_version_ |
1777407910371917824 |