Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim

Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relativel...

Full description

Bibliographic Details
Main Author: Abdul Halim, Muhamad Hazwan
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/14074/
http://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf
id uitm-14074
recordtype eprints
spelling uitm-140742016-06-13T08:37:58Z http://ir.uitm.edu.my/id/eprint/14074/ Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim Abdul Halim, Muhamad Hazwan Image processing Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relatively low-cost advantages. The improvement in ultrasound method for fat measurement is not only on the advancement of the ultrasound equipment but also the accuracy of data analysis. Two current issues that have arisen are the influence of protective layer on the accuracy of ultrasonic velocity measurement using A-mode analysis and the B-mode image positioning accuracy due to the application of the predetermined ultrasonic velocity in B-mode imaging. This research implemented new approach in performing the measurement of ultrasonic velocity and ultrasound B-mode analysis. To increase the accuracy of ultrasonic velocity measurement, the thickness of the protective layer was first determined used in ultrasonic velocity measurement. To increase the positioning accuracy of B-mode image, the actual determined velocity was used rather than the predetermined velocity. The improvements made were successful in increasing the accuracy of the ultrasonic velocity measurement and the positioning of the B - mode image. Subsequently, this method was then used to measure intramuscular fat content in chicken fillet. Better correlations between the ultrasound properties (velocity, image histogram mean and percentages of fat pixel) and percentage of fat content measured by Soxhlet Method were observed in the improved method. In the conclusion, the accuracy of ultrasound fat measurement improved with the improvement made on ultrasonic velocity measurement used in adapted B-mode imaging 2015 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf Abdul Halim, Muhamad Hazwan (2015) Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim. Masters thesis, Universiti Teknologi MARA.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Image processing
spellingShingle Image processing
Abdul Halim, Muhamad Hazwan
Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
description Fat measurement is one of the methods used in meat quality assessments. The need to perform the assessment non-invasively motivates researchers to study the non-invasive methods for fat measurement. For that purpose, ultrasound has the best prospect due to its non-invasive, time saving and relatively low-cost advantages. The improvement in ultrasound method for fat measurement is not only on the advancement of the ultrasound equipment but also the accuracy of data analysis. Two current issues that have arisen are the influence of protective layer on the accuracy of ultrasonic velocity measurement using A-mode analysis and the B-mode image positioning accuracy due to the application of the predetermined ultrasonic velocity in B-mode imaging. This research implemented new approach in performing the measurement of ultrasonic velocity and ultrasound B-mode analysis. To increase the accuracy of ultrasonic velocity measurement, the thickness of the protective layer was first determined used in ultrasonic velocity measurement. To increase the positioning accuracy of B-mode image, the actual determined velocity was used rather than the predetermined velocity. The improvements made were successful in increasing the accuracy of the ultrasonic velocity measurement and the positioning of the B - mode image. Subsequently, this method was then used to measure intramuscular fat content in chicken fillet. Better correlations between the ultrasound properties (velocity, image histogram mean and percentages of fat pixel) and percentage of fat content measured by Soxhlet Method were observed in the improved method. In the conclusion, the accuracy of ultrasound fat measurement improved with the improvement made on ultrasonic velocity measurement used in adapted B-mode imaging
format Thesis
author Abdul Halim, Muhamad Hazwan
author_facet Abdul Halim, Muhamad Hazwan
author_sort Abdul Halim, Muhamad Hazwan
title Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_short Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_full Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_fullStr Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_full_unstemmed Improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / Muhamad Hazwan Abdul Halim
title_sort improved measurement of ultrasound a-mode velocity for use in b-mode images for measurement of fat using image segmentation technique / muhamad hazwan abdul halim
publishDate 2015
url http://ir.uitm.edu.my/id/eprint/14074/
http://ir.uitm.edu.my/id/eprint/14074/1/TM_MUHAMAD%20HAZWAN%20ABDUL%20HALIM%20EE%2015_5.pdf
first_indexed 2023-09-18T22:50:49Z
last_indexed 2023-09-18T22:50:49Z
_version_ 1777417531699494912