Indoor air quality assessment in enclosed car park / Nur Shuhada Izam

Generally, this study concerned about the indoor air quality assessment in enclosed car park. It is related about the building management indoor air control in the commercial building in Plaza Perangsang, Plaza Alam Sentral and Complex PKNS. The aims of the study to assess the indoor air quality in...

Full description

Bibliographic Details
Main Author: Izam, Nur Shuhada
Format: Student Project
Language:English
Published: Faculty of Architecture, Planning and Surveying 2015
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/15737/
http://ir.uitm.edu.my/id/eprint/15737/1/PPb_NUR%20SHUHADA%20IZAM%20AP%2015_5.pdf
id uitm-15737
recordtype eprints
spelling uitm-157372016-12-06T14:07:16Z http://ir.uitm.edu.my/id/eprint/15737/ Indoor air quality assessment in enclosed car park / Nur Shuhada Izam Izam, Nur Shuhada Indoor air pollution. Including indoor air quality Malaysia Generally, this study concerned about the indoor air quality assessment in enclosed car park. It is related about the building management indoor air control in the commercial building in Plaza Perangsang, Plaza Alam Sentral and Complex PKNS. The aims of the study to assess the indoor air quality in enclosed car park and to determine the concentration of gas in the area. It has three objectives that need to be achieved. Firstly to understanding the important of indoor air quality in enclosed car park, secondly to analyze the effectiveness indoor air quality in enclosed car park, thirdly to measure the reading of indoor air quality enclosed car park and last one is to give recommendation to improve the indoor air quality in enclosed car park. The research methodology that has been implemented during the research is through the sampling of air quality. In this study the sample reading of gas CO and C02 will be collect to assess the level of concentration and it will be collect in unit ppm. The gas reading will be made of 10 minute interval for 1 hour duration in the afternoon and evening. Through the sampling data will be analyses whether the air qualities comply with the requirement and standard of Malaysia guidelines. All the data has been presented or show into the forms of table and graph. Finding shows that the Plaza Alam Sentral has the poor indoor air quality in enclosed car park maybe either the lack maintenance of service, poor ventilation system or design. While the Plaza Perangsang and Complex PKNS in a good condition of air quality. The readings of gas concentration exceed the air quality guidelines. It is supported by the questionnaire session where respondent agree the Plaza Alam Sentral have a poor indoor air quality. Recommendations are made to improve the indoor air quality in enclosed car park to provide the effectiveness of ventilation system. Faculty of Architecture, Planning and Surveying 2015 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/15737/1/PPb_NUR%20SHUHADA%20IZAM%20AP%2015_5.pdf Izam, Nur Shuhada (2015) Indoor air quality assessment in enclosed car park / Nur Shuhada Izam. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Indoor air pollution. Including indoor air quality
Malaysia
spellingShingle Indoor air pollution. Including indoor air quality
Malaysia
Izam, Nur Shuhada
Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
description Generally, this study concerned about the indoor air quality assessment in enclosed car park. It is related about the building management indoor air control in the commercial building in Plaza Perangsang, Plaza Alam Sentral and Complex PKNS. The aims of the study to assess the indoor air quality in enclosed car park and to determine the concentration of gas in the area. It has three objectives that need to be achieved. Firstly to understanding the important of indoor air quality in enclosed car park, secondly to analyze the effectiveness indoor air quality in enclosed car park, thirdly to measure the reading of indoor air quality enclosed car park and last one is to give recommendation to improve the indoor air quality in enclosed car park. The research methodology that has been implemented during the research is through the sampling of air quality. In this study the sample reading of gas CO and C02 will be collect to assess the level of concentration and it will be collect in unit ppm. The gas reading will be made of 10 minute interval for 1 hour duration in the afternoon and evening. Through the sampling data will be analyses whether the air qualities comply with the requirement and standard of Malaysia guidelines. All the data has been presented or show into the forms of table and graph. Finding shows that the Plaza Alam Sentral has the poor indoor air quality in enclosed car park maybe either the lack maintenance of service, poor ventilation system or design. While the Plaza Perangsang and Complex PKNS in a good condition of air quality. The readings of gas concentration exceed the air quality guidelines. It is supported by the questionnaire session where respondent agree the Plaza Alam Sentral have a poor indoor air quality. Recommendations are made to improve the indoor air quality in enclosed car park to provide the effectiveness of ventilation system.
format Student Project
author Izam, Nur Shuhada
author_facet Izam, Nur Shuhada
author_sort Izam, Nur Shuhada
title Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
title_short Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
title_full Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
title_fullStr Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
title_full_unstemmed Indoor air quality assessment in enclosed car park / Nur Shuhada Izam
title_sort indoor air quality assessment in enclosed car park / nur shuhada izam
publisher Faculty of Architecture, Planning and Surveying
publishDate 2015
url http://ir.uitm.edu.my/id/eprint/15737/
http://ir.uitm.edu.my/id/eprint/15737/1/PPb_NUR%20SHUHADA%20IZAM%20AP%2015_5.pdf
first_indexed 2023-09-18T22:54:32Z
last_indexed 2023-09-18T22:54:32Z
_version_ 1777417765332713472