Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan

Monitoring system has been a crucial process in any system which relates to the observing and examining the system in detail. The needs of having the monitoring system are sometimes to improve the system itself, to observe the vital changes that will affect the system or anything related, and to loo...

Full description

Bibliographic Details
Main Author: Mahzan, Najwa Nasuha
Format: Thesis
Language:English
Published: 2016
Online Access:http://ir.uitm.edu.my/id/eprint/17793/
http://ir.uitm.edu.my/id/eprint/17793/2/TM_NAJWA%20NASUHA%20MAHZAN%20EE%2016_5.pdf
id uitm-17793
recordtype eprints
spelling uitm-177932018-10-05T07:23:24Z http://ir.uitm.edu.my/id/eprint/17793/ Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan Mahzan, Najwa Nasuha Monitoring system has been a crucial process in any system which relates to the observing and examining the system in detail. The needs of having the monitoring system are sometimes to improve the system itself, to observe the vital changes that will affect the system or anything related, and to look for the system's performances for future reference. Thus, it is essential to have a good data logger which able to capture plenty of data from many sensors where all the data will be stored in huge data storage by means of having a bigger size of memory storage without being supervised frequently. A proposed data logger which implied a microcontroller of ATmega 2560 is introduced where it equips with many channels for taking data from stacks of sensors and definitely is having a gigantic size of memory to store the received data; two SD cards with the size of 4GB each are used throughout the project. The proposed data logger can be used in any systems which are related to electrical as well as in meteorological system provided that the sensors have electrical output that can be read directly or through signal conditioning. Based on the result testing from the proposed data logger, it has shown the low sampling rate in logging process where it could contribute much in logging stage under users' preferences, the low swapping time between two SD cards as low as 1.40 ms when error occurred which can activate the second memory storage immediately without hassle, and lastly the workability of the data logger performances via its characteristics. 2016 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/17793/2/TM_NAJWA%20NASUHA%20MAHZAN%20EE%2016_5.pdf Mahzan, Najwa Nasuha (2016) Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan. Masters thesis, Universiti Teknologi MARA.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description Monitoring system has been a crucial process in any system which relates to the observing and examining the system in detail. The needs of having the monitoring system are sometimes to improve the system itself, to observe the vital changes that will affect the system or anything related, and to look for the system's performances for future reference. Thus, it is essential to have a good data logger which able to capture plenty of data from many sensors where all the data will be stored in huge data storage by means of having a bigger size of memory storage without being supervised frequently. A proposed data logger which implied a microcontroller of ATmega 2560 is introduced where it equips with many channels for taking data from stacks of sensors and definitely is having a gigantic size of memory to store the received data; two SD cards with the size of 4GB each are used throughout the project. The proposed data logger can be used in any systems which are related to electrical as well as in meteorological system provided that the sensors have electrical output that can be read directly or through signal conditioning. Based on the result testing from the proposed data logger, it has shown the low sampling rate in logging process where it could contribute much in logging stage under users' preferences, the low swapping time between two SD cards as low as 1.40 ms when error occurred which can activate the second memory storage immediately without hassle, and lastly the workability of the data logger performances via its characteristics.
format Thesis
author Mahzan, Najwa Nasuha
spellingShingle Mahzan, Najwa Nasuha
Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
author_facet Mahzan, Najwa Nasuha
author_sort Mahzan, Najwa Nasuha
title Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
title_short Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
title_full Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
title_fullStr Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
title_full_unstemmed Design and development of data logger with multiple SD cards for photovoltaic system / Najwa Nasuha Mahzan
title_sort design and development of data logger with multiple sd cards for photovoltaic system / najwa nasuha mahzan
publishDate 2016
url http://ir.uitm.edu.my/id/eprint/17793/
http://ir.uitm.edu.my/id/eprint/17793/2/TM_NAJWA%20NASUHA%20MAHZAN%20EE%2016_5.pdf
first_indexed 2023-09-18T22:59:05Z
last_indexed 2023-09-18T22:59:05Z
_version_ 1777418051449257984