Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat

A study on ‘The Behaviour Of Profiled Steel Sheet Folded Plate Structure With Door Opening’ was carried out in the Civil Engineering Laboratory. The selected profiled steel sheets for the testing are namely called ‘Bondek II’ (corrugated steel sheet) and the specimen models was made by BHP Steel Bui...

Full description

Bibliographic Details
Main Author: Salehat, Mariaty
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 2001
Online Access:http://ir.uitm.edu.my/id/eprint/18066/
http://ir.uitm.edu.my/id/eprint/18066/1/PPb_MARIATY%20SALEHAT%20EC%2001_5.pdf
id uitm-18066
recordtype eprints
spelling uitm-180662017-10-31T05:51:25Z http://ir.uitm.edu.my/id/eprint/18066/ Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat Salehat, Mariaty A study on ‘The Behaviour Of Profiled Steel Sheet Folded Plate Structure With Door Opening’ was carried out in the Civil Engineering Laboratory. The selected profiled steel sheets for the testing are namely called ‘Bondek II’ (corrugated steel sheet) and the specimen models was made by BHP Steel Building Products (M) Sdn. Bhd. Shah Alam. The Bondek II steel sheeting is roll-formed from hotdipped, zinc coated, and chromate passivated high-strength grade BHP Zinc Hi- Ten steel strip. Bondek II (corrugated sheet) has sheet thickness t = 1 mm, depth of fold /* = 54 mm, sheet width a = 600 mm and length of models is / = 1000 mm. A compressive test was carried on the Bondek II specimen models. The experimental investigation was on four full-scale models of profiled sheet subjected to in-plane axial compressive loading, P. The model tested included two models without door opening. The size of door opening is 180 mm width and 700 mm height which has been converted from the standard door size of 900 mm width x 2100 mm (3 ft x 7 ft). The results of specimens without opening obtained from the experimental work are used as guide to the specimens with door opening. The parameters measured and determined are lateral deflection, buckling and ultimate load capacity. From the experimental test, the load displacement curve and stress-strain pattern was plotted and identified. From this study, the ultimate load capacity of compressed profiled steel with door opening was identified to be smaller than that without opening. This may be because the opening reduced the carrying capacity of the models. The openings also tend to increase the deflection of the models. The specimen with opening is noticed to buckle much faster than without opening. It was also found that the buckling shape occurred at different location for each specimen. The average ultimate load capacity for the specimens without opening determined from the experimental test carried out is 159.95 kN and the ultimate load capacity for the specimens with door opening is 109.15 kN. The average percentage different of ultimate load between specimens without opening and with opening is approximately 32 percent. Faculty of Civil Engineering 2001 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18066/1/PPb_MARIATY%20SALEHAT%20EC%2001_5.pdf Salehat, Mariaty (2001) Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description A study on ‘The Behaviour Of Profiled Steel Sheet Folded Plate Structure With Door Opening’ was carried out in the Civil Engineering Laboratory. The selected profiled steel sheets for the testing are namely called ‘Bondek II’ (corrugated steel sheet) and the specimen models was made by BHP Steel Building Products (M) Sdn. Bhd. Shah Alam. The Bondek II steel sheeting is roll-formed from hotdipped, zinc coated, and chromate passivated high-strength grade BHP Zinc Hi- Ten steel strip. Bondek II (corrugated sheet) has sheet thickness t = 1 mm, depth of fold /* = 54 mm, sheet width a = 600 mm and length of models is / = 1000 mm. A compressive test was carried on the Bondek II specimen models. The experimental investigation was on four full-scale models of profiled sheet subjected to in-plane axial compressive loading, P. The model tested included two models without door opening. The size of door opening is 180 mm width and 700 mm height which has been converted from the standard door size of 900 mm width x 2100 mm (3 ft x 7 ft). The results of specimens without opening obtained from the experimental work are used as guide to the specimens with door opening. The parameters measured and determined are lateral deflection, buckling and ultimate load capacity. From the experimental test, the load displacement curve and stress-strain pattern was plotted and identified. From this study, the ultimate load capacity of compressed profiled steel with door opening was identified to be smaller than that without opening. This may be because the opening reduced the carrying capacity of the models. The openings also tend to increase the deflection of the models. The specimen with opening is noticed to buckle much faster than without opening. It was also found that the buckling shape occurred at different location for each specimen. The average ultimate load capacity for the specimens without opening determined from the experimental test carried out is 159.95 kN and the ultimate load capacity for the specimens with door opening is 109.15 kN. The average percentage different of ultimate load between specimens without opening and with opening is approximately 32 percent.
format Student Project
author Salehat, Mariaty
spellingShingle Salehat, Mariaty
Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
author_facet Salehat, Mariaty
author_sort Salehat, Mariaty
title Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
title_short Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
title_full Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
title_fullStr Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
title_full_unstemmed Behaviour of profiled steel sheet folded plate with door opening / Mariaty Salehat
title_sort behaviour of profiled steel sheet folded plate with door opening / mariaty salehat
publisher Faculty of Civil Engineering
publishDate 2001
url http://ir.uitm.edu.my/id/eprint/18066/
http://ir.uitm.edu.my/id/eprint/18066/1/PPb_MARIATY%20SALEHAT%20EC%2001_5.pdf
first_indexed 2023-09-18T22:59:41Z
last_indexed 2023-09-18T22:59:41Z
_version_ 1777418089447555072