Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad

The study of the behaviour of plain concrete beam under sinusoidal dynamic load as well as static loading with respect to the serviceability and ultimate limits is undertaken. A total of four (4) beams with minimum strength of 60 N/mm² had been cast. One beam underwent static load test to failure....

Full description

Bibliographic Details
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 1997
Online Access:http://ir.uitm.edu.my/id/eprint/18116/
http://ir.uitm.edu.my/id/eprint/18116/1/PPb_ROSLAN%20MOHAMMAD%20EC%2097_5.pdf
id uitm-18116
recordtype eprints
spelling uitm-181162017-10-31T07:51:03Z http://ir.uitm.edu.my/id/eprint/18116/ Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad The study of the behaviour of plain concrete beam under sinusoidal dynamic load as well as static loading with respect to the serviceability and ultimate limits is undertaken. A total of four (4) beams with minimum strength of 60 N/mm² had been cast. One beam underwent static load test to failure. The purpose of this test is to determine the yield load of the beams, hence 50% of the yield load will be the mean load for dynamic test. Only two beams underwent sinusoidal repeated load with specified mean load. One specimen underwent one million cycles and another three million cycles. Faculty of Civil Engineering 1997 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18116/1/PPb_ROSLAN%20MOHAMMAD%20EC%2097_5.pdf UNSPECIFIED (1997) Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description The study of the behaviour of plain concrete beam under sinusoidal dynamic load as well as static loading with respect to the serviceability and ultimate limits is undertaken. A total of four (4) beams with minimum strength of 60 N/mm² had been cast. One beam underwent static load test to failure. The purpose of this test is to determine the yield load of the beams, hence 50% of the yield load will be the mean load for dynamic test. Only two beams underwent sinusoidal repeated load with specified mean load. One specimen underwent one million cycles and another three million cycles.
format Student Project
title Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
spellingShingle Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
title_short Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
title_full Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
title_fullStr Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
title_full_unstemmed Behaviour of plain concrete beam under sinusoidal dynamic load / Roslan Mohammad
title_sort behaviour of plain concrete beam under sinusoidal dynamic load / roslan mohammad
publisher Faculty of Civil Engineering
publishDate 1997
url http://ir.uitm.edu.my/id/eprint/18116/
http://ir.uitm.edu.my/id/eprint/18116/1/PPb_ROSLAN%20MOHAMMAD%20EC%2097_5.pdf
first_indexed 2023-09-18T22:59:48Z
last_indexed 2023-09-18T22:59:48Z
_version_ 1777418096565288960