Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman

Wire mesh reinforced concrete wall panel is the new method currently used to replace the conventional wall. It is currently used in the construction of high rise building in Klang Valley, Malaysia. The formwork used for the construction of the wall is by using tunnel form system. It is fast and cost...

Full description

Bibliographic Details
Main Author: Kamarul Zaman, Sezleen Bahzme
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 2006
Online Access:http://ir.uitm.edu.my/id/eprint/18121/
http://ir.uitm.edu.my/id/eprint/18121/2/PPb_SAZLEEN%20BAHZME%20KAMARUL%20ZAMAN%20EC%2006_5.pdf
id uitm-18121
recordtype eprints
spelling uitm-181212019-04-25T02:27:45Z http://ir.uitm.edu.my/id/eprint/18121/ Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman Kamarul Zaman, Sezleen Bahzme Wire mesh reinforced concrete wall panel is the new method currently used to replace the conventional wall. It is currently used in the construction of high rise building in Klang Valley, Malaysia. The formwork used for the construction of the wall is by using tunnel form system. It is fast and cost effective compared to the conventional method. This is an experimental work involving three wall panel reinforced with double layer of wire mesh type B385 (B7) with a dimension of 75x1000x1500 mm (Width:Length:Height). The aspect ratio (h/L) and slenderness ratio (h/t) of the wall panel are 1.5 and 20 respectively. The wall panels were constructed using concrete Grade 30 Normal Ordinary Portland Cement (OPC) with a water cement ratio of 0.58. These wall panel are tested under direct axial line load (without eccentricity) to monitored the structural performance of the wall. Experimental result shows that all wall panels failed in compression shear based on the cracking propagation of the entire wall. The wall panel split into two sections at the middle width of the wall panel. It was found that all the crack lines occur at the side of the wall panel. There are no cracks which occurred at both front and rear surfaces of the wall panel. Maximum deflection recorded at ultimate load was located at the top of the wall. The wall panels swayed to the front of the wall panel. The reinforcement strain was measured by two vertical strain gauges and two horizontal strain gauges. It was found that as the crack progresses the strain experienced by the longitudinal bars at both sides also increased in both wall panels. However, there are no major changes in the strain measurement by the cross bars for both wall panels. The structural performances of the reinforced concrete wall panel have been observed and understood. It had provided useful information to design wall panel when reinforced with wire fabric. Since there is no proper standard and design procedure, this understanding could provide sustainable development in promoting fast and economical construction. hus for future study, it is recommended that the experimental procedure and method of study being varied to gain a better understanding of the structural performance of the reinforced concrete wall panels. Faculty of Civil Engineering 2006 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18121/2/PPb_SAZLEEN%20BAHZME%20KAMARUL%20ZAMAN%20EC%2006_5.pdf Kamarul Zaman, Sezleen Bahzme (2006) Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description Wire mesh reinforced concrete wall panel is the new method currently used to replace the conventional wall. It is currently used in the construction of high rise building in Klang Valley, Malaysia. The formwork used for the construction of the wall is by using tunnel form system. It is fast and cost effective compared to the conventional method. This is an experimental work involving three wall panel reinforced with double layer of wire mesh type B385 (B7) with a dimension of 75x1000x1500 mm (Width:Length:Height). The aspect ratio (h/L) and slenderness ratio (h/t) of the wall panel are 1.5 and 20 respectively. The wall panels were constructed using concrete Grade 30 Normal Ordinary Portland Cement (OPC) with a water cement ratio of 0.58. These wall panel are tested under direct axial line load (without eccentricity) to monitored the structural performance of the wall. Experimental result shows that all wall panels failed in compression shear based on the cracking propagation of the entire wall. The wall panel split into two sections at the middle width of the wall panel. It was found that all the crack lines occur at the side of the wall panel. There are no cracks which occurred at both front and rear surfaces of the wall panel. Maximum deflection recorded at ultimate load was located at the top of the wall. The wall panels swayed to the front of the wall panel. The reinforcement strain was measured by two vertical strain gauges and two horizontal strain gauges. It was found that as the crack progresses the strain experienced by the longitudinal bars at both sides also increased in both wall panels. However, there are no major changes in the strain measurement by the cross bars for both wall panels. The structural performances of the reinforced concrete wall panel have been observed and understood. It had provided useful information to design wall panel when reinforced with wire fabric. Since there is no proper standard and design procedure, this understanding could provide sustainable development in promoting fast and economical construction. hus for future study, it is recommended that the experimental procedure and method of study being varied to gain a better understanding of the structural performance of the reinforced concrete wall panels.
format Student Project
author Kamarul Zaman, Sezleen Bahzme
spellingShingle Kamarul Zaman, Sezleen Bahzme
Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
author_facet Kamarul Zaman, Sezleen Bahzme
author_sort Kamarul Zaman, Sezleen Bahzme
title Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
title_short Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
title_full Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
title_fullStr Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
title_full_unstemmed Structural performance of wire mesh reinforced concrete wall panel / Sezleen Bahzme Kamarul Zaman
title_sort structural performance of wire mesh reinforced concrete wall panel / sezleen bahzme kamarul zaman
publisher Faculty of Civil Engineering
publishDate 2006
url http://ir.uitm.edu.my/id/eprint/18121/
http://ir.uitm.edu.my/id/eprint/18121/2/PPb_SAZLEEN%20BAHZME%20KAMARUL%20ZAMAN%20EC%2006_5.pdf
first_indexed 2023-09-18T22:59:48Z
last_indexed 2023-09-18T22:59:48Z
_version_ 1777418097280417792