Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin

High strength concrete is not fundamentally different from normal strength concrete, it is different only in its level of strength and associated properties. Research in high strength concrete (HSC) has been identified as priority field of study world wide. As research progresses, and industry gears...

Full description

Bibliographic Details
Format: Student Project
Language:English
Published: Faculty of Civil Engineering 1997
Online Access:http://ir.uitm.edu.my/id/eprint/18136/
http://ir.uitm.edu.my/id/eprint/18136/1/PPb_ZULKIFLI%20SAMSUDIN%20EC%2097_5.pdf
id uitm-18136
recordtype eprints
spelling uitm-181362017-11-01T00:19:58Z http://ir.uitm.edu.my/id/eprint/18136/ Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin High strength concrete is not fundamentally different from normal strength concrete, it is different only in its level of strength and associated properties. Research in high strength concrete (HSC) has been identified as priority field of study world wide. As research progresses, and industry gears itself to production, the use of high strength concrete is set to greatly expand in the twenty-first century. Though we are very familiar with the HRC, its behaviour due to dynamic load is not fully understood. Therefore, as a bench mark, stud}' of plain concrete beam behaviour due to impulsive load in the form of half sine load as well as static loading with respect to the serviceability and ultimate limits will be undertaken. Three beams , sizing 125mm x 150mm x 1400mm , have been tested. One of the beam is loaded with static loading conditions and tested until failure in order to achieve the yield strength of the beam. Whilst two more beams are tested under half sinusoidal repeated constant amplitude load with the maximum and minimum loads being 60% and 50% of the yield load respectively. Deflection and cracks behaviour are studied and compared with the previous work. In the static loading test, there are three stages of response between load and deflection. For dynamic loading there is no increase in deflections after the load reached 10,000 cycles and it is believed that plain concrete beam exhibit a fatigue endurance limit. Faculty of Civil Engineering 1997 Student Project NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/18136/1/PPb_ZULKIFLI%20SAMSUDIN%20EC%2097_5.pdf UNSPECIFIED (1997) Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin. [Student Project] (Unpublished)
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
description High strength concrete is not fundamentally different from normal strength concrete, it is different only in its level of strength and associated properties. Research in high strength concrete (HSC) has been identified as priority field of study world wide. As research progresses, and industry gears itself to production, the use of high strength concrete is set to greatly expand in the twenty-first century. Though we are very familiar with the HRC, its behaviour due to dynamic load is not fully understood. Therefore, as a bench mark, stud}' of plain concrete beam behaviour due to impulsive load in the form of half sine load as well as static loading with respect to the serviceability and ultimate limits will be undertaken. Three beams , sizing 125mm x 150mm x 1400mm , have been tested. One of the beam is loaded with static loading conditions and tested until failure in order to achieve the yield strength of the beam. Whilst two more beams are tested under half sinusoidal repeated constant amplitude load with the maximum and minimum loads being 60% and 50% of the yield load respectively. Deflection and cracks behaviour are studied and compared with the previous work. In the static loading test, there are three stages of response between load and deflection. For dynamic loading there is no increase in deflections after the load reached 10,000 cycles and it is believed that plain concrete beam exhibit a fatigue endurance limit.
format Student Project
title Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
spellingShingle Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
title_short Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
title_full Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
title_fullStr Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
title_full_unstemmed Behaviour of plain concrete beam under half-sine impulse load / Zulkifli Samsudin
title_sort behaviour of plain concrete beam under half-sine impulse load / zulkifli samsudin
publisher Faculty of Civil Engineering
publishDate 1997
url http://ir.uitm.edu.my/id/eprint/18136/
http://ir.uitm.edu.my/id/eprint/18136/1/PPb_ZULKIFLI%20SAMSUDIN%20EC%2097_5.pdf
first_indexed 2023-09-18T22:59:50Z
last_indexed 2023-09-18T22:59:50Z
_version_ 1777418099493961728