Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman
The assessment of post-operative spine using computed tomography (CT) imaging is so challenging in the presence of metal artifacts induced by spinal implants. Metal artifacts can severely affect the quality of CT images, and mislead the diagnosis interpretation. The artifacts are due to the beam har...
Main Author: | |
---|---|
Format: | Book Section |
Language: | English |
Published: |
Institute of Graduate Studies, UiTM
2015
|
Subjects: | |
Online Access: | http://ir.uitm.edu.my/id/eprint/19273/ http://ir.uitm.edu.my/id/eprint/19273/1/ABS_NOOR%20DIYANA%20OSMAN%20TDRA%20VOL%207%20IGS%2015.pdf |
id |
uitm-19273 |
---|---|
recordtype |
eprints |
spelling |
uitm-192732018-06-12T07:28:37Z http://ir.uitm.edu.my/id/eprint/19273/ Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman Osman, Noor Diyana Malaysia The assessment of post-operative spine using computed tomography (CT) imaging is so challenging in the presence of metal artifacts induced by spinal implants. Metal artifacts can severely affect the quality of CT images, and mislead the diagnosis interpretation. The artifacts are due to the beam hardening, photon starvation effect, and inappropriate correction algorithm during image reconstruction. Knowledge on factors affecting the artifacts is crucially important to minimize these artifacts. The main aim of this study is to develop a novel technique for suppression of metal artifacts and this study generally consists three main parts. The first part is the development of a simple phantom useful for metal streaking analysis performed in the second part of this work. A customized phantom was constructed with tissue-equivalent materials and various metal inserts to simulate the streaking artifacts similar to the clinical findings in post-operative spine imaging. In this work, a thorough study on factors influencing the magnitude of metal streak artifacts is presented. There are 3 different variables studied which were metal insert characteristics, exposure factors, and reconstruction parameters. The phantom was scanned using Siemens Definition AS+ CT scanner in Radiology Department, HUSM. All phantom images were acquired using standard field of view (FOV) of 230mm with various acquisition and reconstruction protocols depending on the parameters studied. Standardized regions of interest (ROIs) were defined within the streaking region to obtain 1625 attenuation measurements in Hounsfield units (HU). All data are displayed as mean ± standard deviation (SD). The severity of metal streak in each image was determined by CT fluctuation, and noise at each ROI… Institute of Graduate Studies, UiTM 2015 Book Section PeerReviewed text en http://ir.uitm.edu.my/id/eprint/19273/1/ABS_NOOR%20DIYANA%20OSMAN%20TDRA%20VOL%207%20IGS%2015.pdf Osman, Noor Diyana (2015) Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman. In: The Doctoral Research Abstracts. IPSis Biannual Publication, 7 (7). Institute of Graduate Studies, UiTM, Shah Alam. |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Teknologi MARA |
building |
UiTM Institutional Repository |
collection |
Online Access |
language |
English |
topic |
Malaysia |
spellingShingle |
Malaysia Osman, Noor Diyana Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
description |
The assessment of post-operative spine using computed tomography (CT) imaging is so challenging in the presence of metal artifacts induced by spinal implants. Metal artifacts can severely affect the quality of CT images, and mislead the diagnosis interpretation. The artifacts are due to the beam hardening, photon starvation effect, and inappropriate correction algorithm during image reconstruction. Knowledge on factors affecting the artifacts is crucially important to minimize these artifacts. The main aim of this study is to develop a novel technique for suppression of metal artifacts and this study generally consists three main parts. The first part is the development of a simple phantom useful for metal streaking analysis performed in the second part of this work. A customized phantom was constructed with tissue-equivalent materials and various metal inserts to simulate the streaking artifacts similar to the clinical findings in post-operative spine imaging. In this work, a thorough study on factors influencing the magnitude of metal streak artifacts is presented. There are 3 different variables studied which were metal insert characteristics, exposure factors, and reconstruction parameters. The phantom was scanned using Siemens Definition AS+ CT scanner in Radiology Department, HUSM. All phantom images were acquired using standard field of view (FOV) of 230mm with various acquisition and reconstruction protocols depending on the parameters studied. Standardized regions of interest (ROIs) were defined within the streaking region to obtain 1625 attenuation measurements in Hounsfield units (HU). All data are displayed as mean ± standard deviation (SD). The severity of metal streak in each image was determined by CT fluctuation, and noise at each ROI… |
format |
Book Section |
author |
Osman, Noor Diyana |
author_facet |
Osman, Noor Diyana |
author_sort |
Osman, Noor Diyana |
title |
Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
title_short |
Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
title_full |
Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
title_fullStr |
Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
title_full_unstemmed |
Development of a phantom and metal artifact correction (MAC) algorithm for post-operative spine computed tomography (CT) imaging / Noor Diyana Osman |
title_sort |
development of a phantom and metal artifact correction (mac) algorithm for post-operative spine computed tomography (ct) imaging / noor diyana osman |
publisher |
Institute of Graduate Studies, UiTM |
publishDate |
2015 |
url |
http://ir.uitm.edu.my/id/eprint/19273/ http://ir.uitm.edu.my/id/eprint/19273/1/ABS_NOOR%20DIYANA%20OSMAN%20TDRA%20VOL%207%20IGS%2015.pdf |
first_indexed |
2023-09-18T23:02:13Z |
last_indexed |
2023-09-18T23:02:13Z |
_version_ |
1777418248701083648 |