Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan

This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial...

Full description

Bibliographic Details
Main Author: Norizan, Norhazwan
Format: Thesis
Language:English
Published: 2005
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/21302/
http://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf
id uitm-21302
recordtype eprints
spelling uitm-213022018-10-02T07:42:58Z http://ir.uitm.edu.my/id/eprint/21302/ Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan Norizan, Norhazwan Polymers and polymer manufacture This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial loading condition using a special grip and fixture. The damage zones, aₒ, was determined experimentally using optical microscope. Using the values aₒ, the notched strength of the laminates were then determined using both Average Stress Criterion (ASC) and the Fracture Mechanics Criterion (FMC). These calculated values of notched strengths were then compared with that determined through experimentation. In this project, the results indicated that the notched strengths of the glass fiber/epoxy using the Average Stress Criterion and Fracture Mechanics Criterion are comparable. However, the notched strength predicted by the Fracture Mechanics Criterion was about 50% indifference with the Average Stress Criterion for Kevlar and carbon fiber/epoxy. This might be due to the determination of fracture toughness, Kc, using isotropic solution may not be suitable for these materials. Experimental values of the notched strengths of the laminates under bi-axial loading in the experiments cannot be acceptable due to the problems occurred at the grip. Further improvements are needed to overcome the grip problems or new fixture should be designed and constructed in order to obtain better results in the future. 2005 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf Norizan, Norhazwan (2005) Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan. Degree thesis, Universiti Teknologi MARA.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Polymers and polymer manufacture
spellingShingle Polymers and polymer manufacture
Norizan, Norhazwan
Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
description This project involved in the study of notched strength reduction and determination of damage zone, aₒ, of E-glass, Kevlar and Carbon Fiber/Epoxy composite laminates. The specimen configuration used for this project was 101.6 mmx 101.6 mm with 30 mm diameter central hole and was subjected to bi-axial loading condition using a special grip and fixture. The damage zones, aₒ, was determined experimentally using optical microscope. Using the values aₒ, the notched strength of the laminates were then determined using both Average Stress Criterion (ASC) and the Fracture Mechanics Criterion (FMC). These calculated values of notched strengths were then compared with that determined through experimentation. In this project, the results indicated that the notched strengths of the glass fiber/epoxy using the Average Stress Criterion and Fracture Mechanics Criterion are comparable. However, the notched strength predicted by the Fracture Mechanics Criterion was about 50% indifference with the Average Stress Criterion for Kevlar and carbon fiber/epoxy. This might be due to the determination of fracture toughness, Kc, using isotropic solution may not be suitable for these materials. Experimental values of the notched strengths of the laminates under bi-axial loading in the experiments cannot be acceptable due to the problems occurred at the grip. Further improvements are needed to overcome the grip problems or new fixture should be designed and constructed in order to obtain better results in the future.
format Thesis
author Norizan, Norhazwan
author_facet Norizan, Norhazwan
author_sort Norizan, Norhazwan
title Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_short Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_full Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_fullStr Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_full_unstemmed Notched strength of fiber-reinforced polymer (FRP) / Norhazwan Norizan
title_sort notched strength of fiber-reinforced polymer (frp) / norhazwan norizan
publishDate 2005
url http://ir.uitm.edu.my/id/eprint/21302/
http://ir.uitm.edu.my/id/eprint/21302/1/TD_NORHAZWAN%20NORIZAN%20EM%2005_5.pdf
first_indexed 2023-09-18T23:06:16Z
last_indexed 2023-09-18T23:06:16Z
_version_ 1777418504205500416