Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman

In surveying field, the most important thing that need to be focus is accuracy, whether it is in engineering survey or in photogrammetry survey. In order to provide the best and accurate result, the most important thing is the instruments must be in a good condition. In photogrammetry, the camera th...

Full description

Bibliographic Details
Main Author: Kamaruzaman, Muhammad Haziq Muzaini
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/21609/
http://ir.uitm.edu.my/id/eprint/21609/1/TD_MUHAMMAD%20HAZIQ%20MUZAINI%20KAMARUZAMAN%20AP%20R%2018_5.pdf
id uitm-21609
recordtype eprints
spelling uitm-216092018-09-27T02:25:15Z http://ir.uitm.edu.my/id/eprint/21609/ Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman Kamaruzaman, Muhammad Haziq Muzaini Digital mapping Surveying Digital cameras In surveying field, the most important thing that need to be focus is accuracy, whether it is in engineering survey or in photogrammetry survey. In order to provide the best and accurate result, the most important thing is the instruments must be in a good condition. In photogrammetry, the camera that use to capture image, need to be calibrate. The camera is considered calibrated when the focal length (f), coordinate of the centre of projection of the image (xp,yp) and radial lens distortion coefficient (k1,k2,k3) are known. Camera calibration techniques can be divided into two broad categories that are metric scene based calibration and non- metric scene based calibration. The aim of this study to analyze the accuracy of lab test camera calibration and field test camera calibration quantitatively. There are three objectives in order to complete this study, first is to perform lab test camera calibration and field test camera calibration, second to examine the accuracy between lab test and field test camera calibration and third is to compare the calibration parameter between lab test and field test. The result of this study will be tested for statistical significance. The significance of this study are to show the procedure for camera calibration in UAV mapping, development of medium range calibration platform for UAV camera and proving which method of camera calibration gives the accurate result. 2018-09-18 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/21609/1/TD_MUHAMMAD%20HAZIQ%20MUZAINI%20KAMARUZAMAN%20AP%20R%2018_5.pdf Kamaruzaman, Muhammad Haziq Muzaini (2018) Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman. Degree thesis, Universiti Teknologi Mara Perlis.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Digital mapping
Surveying
Digital cameras
spellingShingle Digital mapping
Surveying
Digital cameras
Kamaruzaman, Muhammad Haziq Muzaini
Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
description In surveying field, the most important thing that need to be focus is accuracy, whether it is in engineering survey or in photogrammetry survey. In order to provide the best and accurate result, the most important thing is the instruments must be in a good condition. In photogrammetry, the camera that use to capture image, need to be calibrate. The camera is considered calibrated when the focal length (f), coordinate of the centre of projection of the image (xp,yp) and radial lens distortion coefficient (k1,k2,k3) are known. Camera calibration techniques can be divided into two broad categories that are metric scene based calibration and non- metric scene based calibration. The aim of this study to analyze the accuracy of lab test camera calibration and field test camera calibration quantitatively. There are three objectives in order to complete this study, first is to perform lab test camera calibration and field test camera calibration, second to examine the accuracy between lab test and field test camera calibration and third is to compare the calibration parameter between lab test and field test. The result of this study will be tested for statistical significance. The significance of this study are to show the procedure for camera calibration in UAV mapping, development of medium range calibration platform for UAV camera and proving which method of camera calibration gives the accurate result.
format Thesis
author Kamaruzaman, Muhammad Haziq Muzaini
author_facet Kamaruzaman, Muhammad Haziq Muzaini
author_sort Kamaruzaman, Muhammad Haziq Muzaini
title Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
title_short Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
title_full Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
title_fullStr Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
title_full_unstemmed Accuracy assessment of non-metric digital camera for lab and field calibration / Muhammad Haziq Muzaini Kamaruzaman
title_sort accuracy assessment of non-metric digital camera for lab and field calibration / muhammad haziq muzaini kamaruzaman
publishDate 2018
url http://ir.uitm.edu.my/id/eprint/21609/
http://ir.uitm.edu.my/id/eprint/21609/1/TD_MUHAMMAD%20HAZIQ%20MUZAINI%20KAMARUZAMAN%20AP%20R%2018_5.pdf
first_indexed 2023-09-18T23:06:56Z
last_indexed 2023-09-18T23:06:56Z
_version_ 1777418545838161920