Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz

Purpose: The aim of this study is to investigate the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp). Methodology: The study was an experimental study. A whole body and RANDO phantom was exposed three times with different kVp techniques by using computed r...

Full description

Bibliographic Details
Main Author: Wan Aziz, Wan Nur‘izzati
Format: Thesis
Language:English
Published: 2015
Subjects:
Online Access:http://ir.uitm.edu.my/id/eprint/22287/
http://ir.uitm.edu.my/id/eprint/22287/1/TD_WAN%20NUR%27IZZATI%20WAN%20AZIZ%20HS%20B%2015_5.pdf
id uitm-22287
recordtype eprints
spelling uitm-222872018-12-26T06:26:52Z http://ir.uitm.edu.my/id/eprint/22287/ Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz Wan Aziz, Wan Nur‘izzati Radiography Diseases of the musculoskeletal system Purpose: The aim of this study is to investigate the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp). Methodology: The study was an experimental study. A whole body and RANDO phantom was exposed three times with different kVp techniques by using computed radiography (CR). The entrance skin doses for testis and ovary were measured by placing the thermoluminescense dosimeters (TLDs). The dose delivered to the testis was measured by create testes using a balloon filled with water and place approximately at location of male testes. Meanwhile, the measurement for ovary dose was done on RANDO phantom at slice 29 and the suitable place for TLD chips placement is 9cm from the anterior surface of abdomen and 6cm from midline based on ‗average size‘ woman. After 24 hour, all TLD chips were read by Harshaw 3500 TLD reader to measure the doses. Result: The descriptive analysis showed that the mean of testis dose is directly proportional to the increase various tube potentials. The mean of ovary dose is inversely proportional to the increase various tube potentials. The mean dose of reduction percentage for ovary is 5.5% which is higher than reduction dose in testis. The mean dose of reduction percentage for testis is about 2.3%. Two-way ANOVA test for reproductive organs doses at various kVp found that there were significant difference between the variables since the p-value is < 0.05 (0.01). The pos-hoc analysis (Tukey‘s) recommends that the p-value is <0.05 (0.01) which indicate that there is a significant difference between various tube potentials and doses in two projections. Conclusion: Increase in kVp techniques significantly increases the testis dose while the ovary dose was decrease when kVp is increase. The mean dose reduction for ovary and testis was approximately about 5.5% and 2.3%. The dose reduced much higher in female compare than male when PA projection is applied to the phantom. Thus, the researcher recommends for the implementation of PA projection for routine lumbar spine examinations. 2015 Thesis NonPeerReviewed text en http://ir.uitm.edu.my/id/eprint/22287/1/TD_WAN%20NUR%27IZZATI%20WAN%20AZIZ%20HS%20B%2015_5.pdf Wan Aziz, Wan Nur‘izzati (2015) Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz. Degree thesis, Universiti Teknologi MARA, Selangor, Puncak Alam Campus.
repository_type Digital Repository
institution_category Local University
institution Universiti Teknologi MARA
building UiTM Institutional Repository
collection Online Access
language English
topic Radiography
Diseases of the musculoskeletal system
spellingShingle Radiography
Diseases of the musculoskeletal system
Wan Aziz, Wan Nur‘izzati
Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
description Purpose: The aim of this study is to investigate the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp). Methodology: The study was an experimental study. A whole body and RANDO phantom was exposed three times with different kVp techniques by using computed radiography (CR). The entrance skin doses for testis and ovary were measured by placing the thermoluminescense dosimeters (TLDs). The dose delivered to the testis was measured by create testes using a balloon filled with water and place approximately at location of male testes. Meanwhile, the measurement for ovary dose was done on RANDO phantom at slice 29 and the suitable place for TLD chips placement is 9cm from the anterior surface of abdomen and 6cm from midline based on ‗average size‘ woman. After 24 hour, all TLD chips were read by Harshaw 3500 TLD reader to measure the doses. Result: The descriptive analysis showed that the mean of testis dose is directly proportional to the increase various tube potentials. The mean of ovary dose is inversely proportional to the increase various tube potentials. The mean dose of reduction percentage for ovary is 5.5% which is higher than reduction dose in testis. The mean dose of reduction percentage for testis is about 2.3%. Two-way ANOVA test for reproductive organs doses at various kVp found that there were significant difference between the variables since the p-value is < 0.05 (0.01). The pos-hoc analysis (Tukey‘s) recommends that the p-value is <0.05 (0.01) which indicate that there is a significant difference between various tube potentials and doses in two projections. Conclusion: Increase in kVp techniques significantly increases the testis dose while the ovary dose was decrease when kVp is increase. The mean dose reduction for ovary and testis was approximately about 5.5% and 2.3%. The dose reduced much higher in female compare than male when PA projection is applied to the phantom. Thus, the researcher recommends for the implementation of PA projection for routine lumbar spine examinations.
format Thesis
author Wan Aziz, Wan Nur‘izzati
author_facet Wan Aziz, Wan Nur‘izzati
author_sort Wan Aziz, Wan Nur‘izzati
title Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
title_short Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
title_full Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
title_fullStr Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
title_full_unstemmed Investigation the effect of AP and PA projections on testis and ovary dose at various tube potentials (kVp) / Wan Nur‘izzati Wan Aziz
title_sort investigation the effect of ap and pa projections on testis and ovary dose at various tube potentials (kvp) / wan nur‘izzati wan aziz
publishDate 2015
url http://ir.uitm.edu.my/id/eprint/22287/
http://ir.uitm.edu.my/id/eprint/22287/1/TD_WAN%20NUR%27IZZATI%20WAN%20AZIZ%20HS%20B%2015_5.pdf
first_indexed 2023-09-18T23:08:21Z
last_indexed 2023-09-18T23:08:21Z
_version_ 1777418634855972864