Highly-sensitive graphene-based flexible pressure sensor platform
In this work, graphene has been utilized as the sensing material for the development of a highly-sensitive flexible pressure sensor platform. It has been demonstrated that a graphene-based pressure sensor platform that is able to measure pressure change of up to 3 psi with a sensitivity of 0.042 psi...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Universiti Kebangsaan Malaysia
2017
|
Online Access: | http://journalarticle.ukm.my/11134/ http://journalarticle.ukm.my/11134/ http://journalarticle.ukm.my/11134/1/19%20Muhammad%20Aniq.pdf |
id |
ukm-11134 |
---|---|
recordtype |
eprints |
spelling |
ukm-111342017-12-21T04:26:56Z http://journalarticle.ukm.my/11134/ Highly-sensitive graphene-based flexible pressure sensor platform Muhammad Aniq Shazni, Lee, Mai Woon Lee, Hing Wah In this work, graphene has been utilized as the sensing material for the development of a highly-sensitive flexible pressure sensor platform. It has been demonstrated that a graphene-based pressure sensor platform that is able to measure pressure change of up to 3 psi with a sensitivity of 0.042 psi-1 and a non-linearity of less than 1% has been accomplished. The developed device, which resides on a flexible platform, will be applicable for integration in continuous wearables health-care monitoring system for the measurement of blood pressure. Penerbit Universiti Kebangsaan Malaysia 2017-07 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/11134/1/19%20Muhammad%20Aniq.pdf Muhammad Aniq Shazni, and Lee, Mai Woon and Lee, Hing Wah (2017) Highly-sensitive graphene-based flexible pressure sensor platform. Sains Malaysiana, 46 (7). pp. 1155-1161. ISSN 0126-6039 http://www.ukm.my/jsm/malay_journals/jilid46bil7_2017/KandunganJilid46Bil7_2017.html |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
language |
English |
description |
In this work, graphene has been utilized as the sensing material for the development of a highly-sensitive flexible pressure sensor platform. It has been demonstrated that a graphene-based pressure sensor platform that is able to measure pressure change of up to 3 psi with a sensitivity of 0.042 psi-1 and a non-linearity of less than 1% has been accomplished. The developed device, which resides on a flexible platform, will be applicable for integration in continuous wearables health-care monitoring system for the measurement of blood pressure. |
format |
Article |
author |
Muhammad Aniq Shazni, Lee, Mai Woon Lee, Hing Wah |
spellingShingle |
Muhammad Aniq Shazni, Lee, Mai Woon Lee, Hing Wah Highly-sensitive graphene-based flexible pressure sensor platform |
author_facet |
Muhammad Aniq Shazni, Lee, Mai Woon Lee, Hing Wah |
author_sort |
Muhammad Aniq Shazni, |
title |
Highly-sensitive graphene-based flexible pressure sensor platform |
title_short |
Highly-sensitive graphene-based flexible pressure sensor platform |
title_full |
Highly-sensitive graphene-based flexible pressure sensor platform |
title_fullStr |
Highly-sensitive graphene-based flexible pressure sensor platform |
title_full_unstemmed |
Highly-sensitive graphene-based flexible pressure sensor platform |
title_sort |
highly-sensitive graphene-based flexible pressure sensor platform |
publisher |
Penerbit Universiti Kebangsaan Malaysia |
publishDate |
2017 |
url |
http://journalarticle.ukm.my/11134/ http://journalarticle.ukm.my/11134/ http://journalarticle.ukm.my/11134/1/19%20Muhammad%20Aniq.pdf |
first_indexed |
2023-09-18T19:59:28Z |
last_indexed |
2023-09-18T19:59:28Z |
_version_ |
1777406751165906944 |