Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
Experiments were done to obtain a correlation between pressure drop across a chromatographic bed packed with a compressible packing, Sephadex G100, and other measurable parameters such as flowrate, column length and diameter, particle size, and permeability. The pressure drop across the bed is ob...
Main Author: | |
---|---|
Format: | Article |
Published: |
1993
|
Online Access: | http://journalarticle.ukm.my/1305/ http://journalarticle.ukm.my/1305/ |
id |
ukm-1305 |
---|---|
recordtype |
eprints |
spelling |
ukm-13052011-10-11T03:45:17Z http://journalarticle.ukm.my/1305/ Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing Abdul Wahab Mohammad, Experiments were done to obtain a correlation between pressure drop across a chromatographic bed packed with a compressible packing, Sephadex G100, and other measurable parameters such as flowrate, column length and diameter, particle size, and permeability. The pressure drop across the bed is obtained by subtracting the extracolumn pressure drop from the operating pressure drop. It was found that the pressure drop increased nonlinearly as the flowrate increased. There is a critical flowrate after which the pressure drop increases infinitely. The pressure drop was also found to be dependent on the column diameter within the range tested. The data were fitted well with an equation similar to the Blake-Kozeny equation but with an exponential term and a critical factor included 1993 Article PeerReviewed Abdul Wahab Mohammad, (1993) Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing. Jurnal Kejuruteraan, 5 . http://www.ukm.my/jkukm/index.php/jkukm |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
description |
Experiments were done to obtain a correlation between pressure drop across a
chromatographic bed packed with a compressible packing, Sephadex G100, and other
measurable parameters such as flowrate, column length and diameter, particle size,
and permeability. The pressure drop across the bed is obtained by subtracting the
extracolumn pressure drop from the operating pressure drop. It was found that the
pressure drop increased nonlinearly as the flowrate increased. There is a critical
flowrate after which the pressure drop increases infinitely. The pressure drop was
also found to be dependent on the column diameter within the range tested. The data
were fitted well with an equation similar to the Blake-Kozeny equation but with an
exponential term and a critical factor included |
format |
Article |
author |
Abdul Wahab Mohammad, |
spellingShingle |
Abdul Wahab Mohammad, Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing |
author_facet |
Abdul Wahab Mohammad, |
author_sort |
Abdul Wahab Mohammad, |
title |
Empirical correlations for pressure drop across A
chromatographic bed packed with A compressible packing |
title_short |
Empirical correlations for pressure drop across A
chromatographic bed packed with A compressible packing |
title_full |
Empirical correlations for pressure drop across A
chromatographic bed packed with A compressible packing |
title_fullStr |
Empirical correlations for pressure drop across A
chromatographic bed packed with A compressible packing |
title_full_unstemmed |
Empirical correlations for pressure drop across A
chromatographic bed packed with A compressible packing |
title_sort |
empirical correlations for pressure drop across a
chromatographic bed packed with a compressible packing |
publishDate |
1993 |
url |
http://journalarticle.ukm.my/1305/ http://journalarticle.ukm.my/1305/ |
first_indexed |
2023-09-18T19:32:57Z |
last_indexed |
2023-09-18T19:32:57Z |
_version_ |
1777405082987397120 |