Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing

Experiments were done to obtain a correlation between pressure drop across a chromatographic bed packed with a compressible packing, Sephadex G100, and other measurable parameters such as flowrate, column length and diameter, particle size, and permeability. The pressure drop across the bed is ob...

Full description

Bibliographic Details
Main Author: Abdul Wahab Mohammad
Format: Article
Published: 1993
Online Access:http://journalarticle.ukm.my/1305/
http://journalarticle.ukm.my/1305/
id ukm-1305
recordtype eprints
spelling ukm-13052011-10-11T03:45:17Z http://journalarticle.ukm.my/1305/ Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing Abdul Wahab Mohammad, Experiments were done to obtain a correlation between pressure drop across a chromatographic bed packed with a compressible packing, Sephadex G100, and other measurable parameters such as flowrate, column length and diameter, particle size, and permeability. The pressure drop across the bed is obtained by subtracting the extracolumn pressure drop from the operating pressure drop. It was found that the pressure drop increased nonlinearly as the flowrate increased. There is a critical flowrate after which the pressure drop increases infinitely. The pressure drop was also found to be dependent on the column diameter within the range tested. The data were fitted well with an equation similar to the Blake-Kozeny equation but with an exponential term and a critical factor included 1993 Article PeerReviewed Abdul Wahab Mohammad, (1993) Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing. Jurnal Kejuruteraan, 5 . http://www.ukm.my/jkukm/index.php/jkukm
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
description Experiments were done to obtain a correlation between pressure drop across a chromatographic bed packed with a compressible packing, Sephadex G100, and other measurable parameters such as flowrate, column length and diameter, particle size, and permeability. The pressure drop across the bed is obtained by subtracting the extracolumn pressure drop from the operating pressure drop. It was found that the pressure drop increased nonlinearly as the flowrate increased. There is a critical flowrate after which the pressure drop increases infinitely. The pressure drop was also found to be dependent on the column diameter within the range tested. The data were fitted well with an equation similar to the Blake-Kozeny equation but with an exponential term and a critical factor included
format Article
author Abdul Wahab Mohammad,
spellingShingle Abdul Wahab Mohammad,
Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
author_facet Abdul Wahab Mohammad,
author_sort Abdul Wahab Mohammad,
title Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
title_short Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
title_full Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
title_fullStr Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
title_full_unstemmed Empirical correlations for pressure drop across A chromatographic bed packed with A compressible packing
title_sort empirical correlations for pressure drop across a chromatographic bed packed with a compressible packing
publishDate 1993
url http://journalarticle.ukm.my/1305/
http://journalarticle.ukm.my/1305/
first_indexed 2023-09-18T19:32:57Z
last_indexed 2023-09-18T19:32:57Z
_version_ 1777405082987397120