Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement

This study investigates the applicability of hydronic radiant cooling system charged with night cooled water to cool down building in Sarawak particularly for low income building to a thermally acceptable level. The system uses night sky as well as the ground as a heat sink source to passively cool...

Full description

Bibliographic Details
Main Authors: M.S. Imran, A. Baharun, S.H. Ibrahim, W.A.W.Z. Abidin
Format: Article
Language:English
Published: Penerbit Universiti Kebangsaan Malaysia 2016
Online Access:http://journalarticle.ukm.my/13283/
http://journalarticle.ukm.my/13283/
http://journalarticle.ukm.my/13283/1/198-650-1-PB.pdf
id ukm-13283
recordtype eprints
spelling ukm-132832019-08-26T11:16:08Z http://journalarticle.ukm.my/13283/ Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement M.S. Imran, A. Baharun, S.H. Ibrahim, W.A.W.Z. Abidin, This study investigates the applicability of hydronic radiant cooling system charged with night cooled water to cool down building in Sarawak particularly for low income building to a thermally acceptable level. The system uses night sky as well as the ground as a heat sink source to passively cool the building while operating at a low energy level. Results from building energy simulation program or Energy Plus shows that for a stand-alone hydronic radiant system only 77% of the time the thermal condition could meet ASHRAE acceptable PMV thermal condition between -0.5 and + 0.5. Another simulation of the radiant and earth tube system hybrid further improved the indoor thermal condition significantly by 100% to meet the same PMV level. The hybrid system was able to improve the baseline uncomfortable operative temperature of 37oC to 28.5oC while meeting the average comfort zone upper limit for Malaysia of 30.1 oC. Simulation on energy spent shows that as much as 94% energy could be saved by using the hybrid system. This level of saving is not impossible as renewable night cooled water was used to charge the indoor hydronic radiant cooling system. Penerbit Universiti Kebangsaan Malaysia 2016 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/13283/1/198-650-1-PB.pdf M.S. Imran, and A. Baharun, and S.H. Ibrahim, and W.A.W.Z. Abidin, (2016) Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement. Journal of Building Performance, 7 (1). pp. 56-71. ISSN 2180-2106 http://spaj.ukm.my/jsb/index.php/jbp/issue/view/33
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description This study investigates the applicability of hydronic radiant cooling system charged with night cooled water to cool down building in Sarawak particularly for low income building to a thermally acceptable level. The system uses night sky as well as the ground as a heat sink source to passively cool the building while operating at a low energy level. Results from building energy simulation program or Energy Plus shows that for a stand-alone hydronic radiant system only 77% of the time the thermal condition could meet ASHRAE acceptable PMV thermal condition between -0.5 and + 0.5. Another simulation of the radiant and earth tube system hybrid further improved the indoor thermal condition significantly by 100% to meet the same PMV level. The hybrid system was able to improve the baseline uncomfortable operative temperature of 37oC to 28.5oC while meeting the average comfort zone upper limit for Malaysia of 30.1 oC. Simulation on energy spent shows that as much as 94% energy could be saved by using the hybrid system. This level of saving is not impossible as renewable night cooled water was used to charge the indoor hydronic radiant cooling system.
format Article
author M.S. Imran,
A. Baharun,
S.H. Ibrahim,
W.A.W.Z. Abidin,
spellingShingle M.S. Imran,
A. Baharun,
S.H. Ibrahim,
W.A.W.Z. Abidin,
Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
author_facet M.S. Imran,
A. Baharun,
S.H. Ibrahim,
W.A.W.Z. Abidin,
author_sort M.S. Imran,
title Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
title_short Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
title_full Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
title_fullStr Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
title_full_unstemmed Renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
title_sort renewable indoor radiant cooling and earth tube heat exchanger hybrid for thermal comfort improvement
publisher Penerbit Universiti Kebangsaan Malaysia
publishDate 2016
url http://journalarticle.ukm.my/13283/
http://journalarticle.ukm.my/13283/
http://journalarticle.ukm.my/13283/1/198-650-1-PB.pdf
first_indexed 2023-09-18T20:04:30Z
last_indexed 2023-09-18T20:04:30Z
_version_ 1777407068349661184