Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode
An ultraviolet A (UVA) radiation intensity sensor with responsivity in the wavelength range of 320-360 nm was developed based on a gallium nitride (GaN) photodiode. In this sensor system, a GaN photodiode in reverse-biased mode converts the radiation intensity into current, which was then converted...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Kebangsaan Malaysia
2011
|
Online Access: | http://journalarticle.ukm.my/2441/ http://journalarticle.ukm.my/2441/ http://journalarticle.ukm.my/2441/1/06_Theyirakumar.pdf |
id |
ukm-2441 |
---|---|
recordtype |
eprints |
spelling |
ukm-24412016-12-14T06:31:37Z http://journalarticle.ukm.my/2441/ Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode Theyirakumar .J, Gopir .G, Yatim .B, Sanusi .H, Megat Mahmud .P.S, Hoe .P.C, An ultraviolet A (UVA) radiation intensity sensor with responsivity in the wavelength range of 320-360 nm was developed based on a gallium nitride (GaN) photodiode. In this sensor system, a GaN photodiode in reverse-biased mode converts the radiation intensity into current, which was then converted and amplified into an output voltage by a transimpedance amplifier (TIA), or current-voltage converter, consisting of an operational amplifier and a feedback resistor. For a narrowband UV source, the radiation intensity could be calculated from the values of the output voltage, feedback resistor, photodiode responsivity and photodiode effective area. The sensor was tested by performing measurements over different values of UV source wavelength, source distance, ambient temperature and sampling time. For calibration with a broadband UV source, the GaN-UVA sensor was used simultaneously with a standard Si-UVA sensor to measure solar radiation. The observed linear relationship between the sensors’ outputs enables us to convert the output voltage of the GaN-UVA sensor to UVA intensity. Thus, we have successfully developed, tested and calibrated an ultraviolet A radiation sensor based on the GaN photodiode. Universiti Kebangsaan Malaysia 2011-01 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/2441/1/06_Theyirakumar.pdf Theyirakumar .J, and Gopir .G, and Yatim .B, and Sanusi .H, and Megat Mahmud .P.S, and Hoe .P.C, (2011) Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode. Sains Malaysiana, 40 (1). pp. 21-25. ISSN 0126-6039 http://www.ukm.my/jsm/ |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
language |
English |
description |
An ultraviolet A (UVA) radiation intensity sensor with responsivity in the wavelength range of 320-360 nm was developed based on a gallium nitride (GaN) photodiode. In this sensor system, a GaN photodiode in reverse-biased mode converts the radiation intensity into current, which was then converted and amplified into an output voltage by a transimpedance amplifier (TIA), or current-voltage converter, consisting of an operational amplifier and a feedback resistor. For a narrowband UV source, the radiation intensity could be calculated from the values of the output voltage, feedback resistor, photodiode responsivity and photodiode effective area. The sensor was tested by performing measurements over different values of UV source wavelength, source distance, ambient temperature and sampling time. For calibration with a broadband UV source, the GaN-UVA sensor was used simultaneously with a standard Si-UVA sensor to measure solar radiation. The observed linear relationship between the sensors’ outputs enables us to convert the output voltage of the GaN-UVA sensor to UVA intensity. Thus, we have successfully developed, tested and calibrated an ultraviolet A radiation
sensor based on the GaN photodiode. |
format |
Article |
author |
Theyirakumar .J, Gopir .G, Yatim .B, Sanusi .H, Megat Mahmud .P.S, Hoe .P.C, |
spellingShingle |
Theyirakumar .J, Gopir .G, Yatim .B, Sanusi .H, Megat Mahmud .P.S, Hoe .P.C, Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
author_facet |
Theyirakumar .J, Gopir .G, Yatim .B, Sanusi .H, Megat Mahmud .P.S, Hoe .P.C, |
author_sort |
Theyirakumar .J, |
title |
Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
title_short |
Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
title_full |
Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
title_fullStr |
Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
title_full_unstemmed |
Testing and calibration of an ultraviolet-a radiation sensor based on GaN photodiode |
title_sort |
testing and calibration of an ultraviolet-a radiation sensor based on gan photodiode |
publisher |
Universiti Kebangsaan Malaysia |
publishDate |
2011 |
url |
http://journalarticle.ukm.my/2441/ http://journalarticle.ukm.my/2441/ http://journalarticle.ukm.my/2441/1/06_Theyirakumar.pdf |
first_indexed |
2023-09-18T19:36:05Z |
last_indexed |
2023-09-18T19:36:05Z |
_version_ |
1777405279800918016 |