Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model

The urinary bladder can be affected by either congenital or acquired disease leading to small, noncompliant, hypertonic urinary bladder with subsequent transfer of high pressure to upper tract leading to renal function deterioration and renal failure. The aim of urinary bladder reconstruction was to...

Full description

Bibliographic Details
Main Authors: Salah AS, Angela Ng MH, Christopher Ho CK, Ismail S, Ruszymah BHI, Zulkifili MDZ
Format: Article
Language:English
Published: Department of Surgery, UKM Medical Centre 2011
Online Access:http://journalarticle.ukm.my/2961/
http://journalarticle.ukm.my/2961/
http://journalarticle.ukm.my/2961/1/25-32.pdf
id ukm-2961
recordtype eprints
spelling ukm-29612016-12-14T06:33:11Z http://journalarticle.ukm.my/2961/ Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model Salah AS, Angela Ng MH, Christopher Ho CK, Ismail S, Ruszymah BHI, Zulkifili MDZ, The urinary bladder can be affected by either congenital or acquired disease leading to small, noncompliant, hypertonic urinary bladder with subsequent transfer of high pressure to upper tract leading to renal function deterioration and renal failure. The aim of urinary bladder reconstruction was to restore normal structure and functions of the urinary bladder. Successful reconstructions should be confirmed by measurement and evaluation of bladder structure and functions. In this study, different modalities such as radiography (CT scan), ultrasonography, and urodynamic were used to assess urinary bladder structure and functions in an animal model. The radiographic (CT scan) and ultrasonography have mostly structural data, while urodynamic studies produce functional parameters. Using these combined modalities we could measure and determine the normal urinary bladder volume, bladder filling pressure, voiding pressure, bladder shape, outline border, three dimension (3D) configurations, locations, and bladder dimensions. Radiography showed bladder as oval, contrast filled hollow organ, localized centrally. Mean bladder volume was 1.42 ml±0.03. Ultrasonography showed bladder as oval, elongated hypo echoic urine filled organ with, wall thickness 1mm at bladder dome and 2mm at bladder base. Mean volume was 1.44 ml±0.05. Urodynamic study showed low intravesical filling pressure with a mean value of 6-5 cm H2O, while the mean voiding pressure was 18-19cmH2O. Mean bladder volume was 1.40 ml±0.02. The acquired data for the normal (control) animals may be used as a reference for further evaluations of our future research on urinary bladder reconstructions using tissue engineering technology. Department of Surgery, UKM Medical Centre 2011-10 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/2961/1/25-32.pdf Salah AS, and Angela Ng MH, and Christopher Ho CK, and Ismail S, and Ruszymah BHI, and Zulkifili MDZ, (2011) Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model. Journal of Surgical Academia, 1 (2). pp. 25-32. ISSN 2231-7481 http://jsurgacad.com/
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description The urinary bladder can be affected by either congenital or acquired disease leading to small, noncompliant, hypertonic urinary bladder with subsequent transfer of high pressure to upper tract leading to renal function deterioration and renal failure. The aim of urinary bladder reconstruction was to restore normal structure and functions of the urinary bladder. Successful reconstructions should be confirmed by measurement and evaluation of bladder structure and functions. In this study, different modalities such as radiography (CT scan), ultrasonography, and urodynamic were used to assess urinary bladder structure and functions in an animal model. The radiographic (CT scan) and ultrasonography have mostly structural data, while urodynamic studies produce functional parameters. Using these combined modalities we could measure and determine the normal urinary bladder volume, bladder filling pressure, voiding pressure, bladder shape, outline border, three dimension (3D) configurations, locations, and bladder dimensions. Radiography showed bladder as oval, contrast filled hollow organ, localized centrally. Mean bladder volume was 1.42 ml±0.03. Ultrasonography showed bladder as oval, elongated hypo echoic urine filled organ with, wall thickness 1mm at bladder dome and 2mm at bladder base. Mean volume was 1.44 ml±0.05. Urodynamic study showed low intravesical filling pressure with a mean value of 6-5 cm H2O, while the mean voiding pressure was 18-19cmH2O. Mean bladder volume was 1.40 ml±0.02. The acquired data for the normal (control) animals may be used as a reference for further evaluations of our future research on urinary bladder reconstructions using tissue engineering technology.
format Article
author Salah AS,
Angela Ng MH,
Christopher Ho CK,
Ismail S,
Ruszymah BHI,
Zulkifili MDZ,
spellingShingle Salah AS,
Angela Ng MH,
Christopher Ho CK,
Ismail S,
Ruszymah BHI,
Zulkifili MDZ,
Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
author_facet Salah AS,
Angela Ng MH,
Christopher Ho CK,
Ismail S,
Ruszymah BHI,
Zulkifili MDZ,
author_sort Salah AS,
title Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
title_short Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
title_full Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
title_fullStr Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
title_full_unstemmed Combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
title_sort combining radiographic, urodynamic and ultrasonographic techniques for the evaluation of urinary bladder structure and function in an animal model
publisher Department of Surgery, UKM Medical Centre
publishDate 2011
url http://journalarticle.ukm.my/2961/
http://journalarticle.ukm.my/2961/
http://journalarticle.ukm.my/2961/1/25-32.pdf
first_indexed 2023-09-18T19:37:27Z
last_indexed 2023-09-18T19:37:27Z
_version_ 1777405366283272192