EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)

Patient skin dose measurements were performed at the cardiology department in a hospital in Penang, Malaysia using EDR films during coronary angiography (CA) procedures. The EDR2 film was first characterized in terms of dose and energy dependence as well reproducibility. For patient dose measurement...

Full description

Bibliographic Details
Main Authors: Ying, C.K, Kandaiya, S
Format: Article
Language:English
Published: Universiti Kebangsaan Malaysia 2012
Online Access:http://journalarticle.ukm.my/3239/
http://journalarticle.ukm.my/3239/
http://journalarticle.ukm.my/3239/1/16%2520C.K.%2520Ying.pdf
id ukm-3239
recordtype eprints
spelling ukm-32392016-12-14T06:34:03Z http://journalarticle.ukm.my/3239/ EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2) Ying, C.K Kandaiya, S Patient skin dose measurements were performed at the cardiology department in a hospital in Penang, Malaysia using EDR films during coronary angiography (CA) procedures. The EDR2 film was first characterized in terms of dose and energy dependence as well reproducibility. For patient dose measurements, the films were placed on the table underneath the patient for an under couch tube position. A total of 27 CA procedures were studied. Results for peak skin doses (PSD) ranged from 35- 684 mGy while the dose area product (DAP) values were from 5.5 to 93.1 Gy cm2. DAP correlated reasonably with PSD for CA procedure (R2= 0.8212). The highest PSD value in this study is below the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration (FDA 1994). Universiti Kebangsaan Malaysia 2012-01 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/3239/1/16%2520C.K.%2520Ying.pdf Ying, C.K and Kandaiya, S (2012) EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2). Sains Malaysiana, 41 (1). pp. 133-140. ISSN 0126-6039 http://www.ukm.my/jsm/contents.html
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description Patient skin dose measurements were performed at the cardiology department in a hospital in Penang, Malaysia using EDR films during coronary angiography (CA) procedures. The EDR2 film was first characterized in terms of dose and energy dependence as well reproducibility. For patient dose measurements, the films were placed on the table underneath the patient for an under couch tube position. A total of 27 CA procedures were studied. Results for peak skin doses (PSD) ranged from 35- 684 mGy while the dose area product (DAP) values were from 5.5 to 93.1 Gy cm2. DAP correlated reasonably with PSD for CA procedure (R2= 0.8212). The highest PSD value in this study is below the threshold dose value of 2 Gy for early transient skin injury recommended by the Food and Drug Administration (FDA 1994).
format Article
author Ying, C.K
Kandaiya, S
spellingShingle Ying, C.K
Kandaiya, S
EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
author_facet Ying, C.K
Kandaiya, S
author_sort Ying, C.K
title EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
title_short EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
title_full EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
title_fullStr EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
title_full_unstemmed EDR2 Film for skin dose measurement in coronary angiography Pengukuran dos kulit dalam koronari angiografi menggunakan filem EDR2)
title_sort edr2 film for skin dose measurement in coronary angiography pengukuran dos kulit dalam koronari angiografi menggunakan filem edr2)
publisher Universiti Kebangsaan Malaysia
publishDate 2012
url http://journalarticle.ukm.my/3239/
http://journalarticle.ukm.my/3239/
http://journalarticle.ukm.my/3239/1/16%2520C.K.%2520Ying.pdf
first_indexed 2023-09-18T19:38:15Z
last_indexed 2023-09-18T19:38:15Z
_version_ 1777405416838266880