Image quality of two full field digital mammography using a female breast phantom

Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualit...

Full description

Bibliographic Details
Main Authors: Kanaga Kumari Chelliah, Ang, Wee Chin, Abd Aziz Tajuddin, Shantini A. Arasaratnam, Suraya Aziz, Laila Suryani Elias
Format: Article
Language:English
Published: Penerbit UKM 2009
Online Access:http://journalarticle.ukm.my/3633/
http://journalarticle.ukm.my/3633/
http://journalarticle.ukm.my/3633/1/Image_Quality_of_Two_Full_Field_Digital.pdf
id ukm-3633
recordtype eprints
spelling ukm-36332016-12-14T06:35:00Z http://journalarticle.ukm.my/3633/ Image quality of two full field digital mammography using a female breast phantom Kanaga Kumari Chelliah, Ang, Wee Chin Abd Aziz Tajuddin, Shantini A. Arasaratnam, Suraya Aziz, Laila Suryani Elias, Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualitative methods of two FFDM systems with variations in breast thickness and anode/ filter combination. This study was done from January to April 2008 with two FFDM systems; Siemens Mammomat NovationDR at Diagnostic Imaging Department, Hospital Kuala Lumpur and Hologic Lorad Selenia at Breast Clinic, National Cancer Society. A CIRS012A tissue equivalent breast phantom (4, 5 and 6 cm) thickness was used to obtain images in the craniocaudal plane with 26-32 kVp and a combination of molybdenum/molybdenum (Mo/Mo) and molybdenum/rhodium (Mo/Rh) anode/filter. For the qualitative evaluation, two independent radiologist with a minimum of five years experience was used to score the images. Wilcoxon Sign Rank Test showed that there are no significant differences (p > 0.05) in image quality between both the FFDM systems. Kappa analysis had a poor agreement between the scores given by the two radiologists. The quantitative analysis using Mann-Whitney test showed that there are significant differences (p < 0.05) between the SNR values of both FFDM systems. Although the qualitative evaluation was similar, the study showed that Lorad Selenia had a significantly superior SNR value, hence would be a better tool to detect early changes in the breast tissue. This study also demonstrated that a lower kVp is more suitable with molybdenum filter and as the breast thickness is increased rhodium filter with higher kVp displayed better quality images. Penerbit UKM 2009 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/3633/1/Image_Quality_of_Two_Full_Field_Digital.pdf Kanaga Kumari Chelliah, and Ang, Wee Chin and Abd Aziz Tajuddin, and Shantini A. Arasaratnam, and Suraya Aziz, and Laila Suryani Elias, (2009) Image quality of two full field digital mammography using a female breast phantom. Jurnal Sains Kesihatan Malaysia, 7 (1). pp. 65-72. ISSN 1675-8161 http://www.fsk.ukm.my/jurnal/jilid%207%281%292009/Chapter7.pdf
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description Digital mammography has been progressively introduced in screening centers and the concern is to achieve an image of diagnostic value which would be able to detect early changes in the breast tissue. The aim of this study was to evaluate the image quality of mammograms using quantitative and qualitative methods of two FFDM systems with variations in breast thickness and anode/ filter combination. This study was done from January to April 2008 with two FFDM systems; Siemens Mammomat NovationDR at Diagnostic Imaging Department, Hospital Kuala Lumpur and Hologic Lorad Selenia at Breast Clinic, National Cancer Society. A CIRS012A tissue equivalent breast phantom (4, 5 and 6 cm) thickness was used to obtain images in the craniocaudal plane with 26-32 kVp and a combination of molybdenum/molybdenum (Mo/Mo) and molybdenum/rhodium (Mo/Rh) anode/filter. For the qualitative evaluation, two independent radiologist with a minimum of five years experience was used to score the images. Wilcoxon Sign Rank Test showed that there are no significant differences (p > 0.05) in image quality between both the FFDM systems. Kappa analysis had a poor agreement between the scores given by the two radiologists. The quantitative analysis using Mann-Whitney test showed that there are significant differences (p < 0.05) between the SNR values of both FFDM systems. Although the qualitative evaluation was similar, the study showed that Lorad Selenia had a significantly superior SNR value, hence would be a better tool to detect early changes in the breast tissue. This study also demonstrated that a lower kVp is more suitable with molybdenum filter and as the breast thickness is increased rhodium filter with higher kVp displayed better quality images.
format Article
author Kanaga Kumari Chelliah,
Ang, Wee Chin
Abd Aziz Tajuddin,
Shantini A. Arasaratnam,
Suraya Aziz,
Laila Suryani Elias,
spellingShingle Kanaga Kumari Chelliah,
Ang, Wee Chin
Abd Aziz Tajuddin,
Shantini A. Arasaratnam,
Suraya Aziz,
Laila Suryani Elias,
Image quality of two full field digital mammography using a female breast phantom
author_facet Kanaga Kumari Chelliah,
Ang, Wee Chin
Abd Aziz Tajuddin,
Shantini A. Arasaratnam,
Suraya Aziz,
Laila Suryani Elias,
author_sort Kanaga Kumari Chelliah,
title Image quality of two full field digital mammography using a female breast phantom
title_short Image quality of two full field digital mammography using a female breast phantom
title_full Image quality of two full field digital mammography using a female breast phantom
title_fullStr Image quality of two full field digital mammography using a female breast phantom
title_full_unstemmed Image quality of two full field digital mammography using a female breast phantom
title_sort image quality of two full field digital mammography using a female breast phantom
publisher Penerbit UKM
publishDate 2009
url http://journalarticle.ukm.my/3633/
http://journalarticle.ukm.my/3633/
http://journalarticle.ukm.my/3633/1/Image_Quality_of_Two_Full_Field_Digital.pdf
first_indexed 2023-09-18T19:39:20Z
last_indexed 2023-09-18T19:39:20Z
_version_ 1777405484898189312