Calculation of mean kidney dose for a Co-57 external radiation source
A description is given of the numerical integration method for the calculation of the mean kidney dose for a Co-57 external radiation source. Based on this theory, a computer program was written. Initial calculation of the kidney volume shows that the method has a good accuracy. For the mean kidney...
| Main Author: | |
|---|---|
| Format: | Article |
| Published: |
Universiti Kebangsaan Malaysia
1996
|
| Online Access: | http://journalarticle.ukm.my/3678/ http://journalarticle.ukm.my/3678/ |
| id |
ukm-3678 |
|---|---|
| recordtype |
eprints |
| spelling |
ukm-36782012-03-29T04:10:01Z http://journalarticle.ukm.my/3678/ Calculation of mean kidney dose for a Co-57 external radiation source Supian Samat, A description is given of the numerical integration method for the calculation of the mean kidney dose for a Co-57 external radiation source. Based on this theory, a computer program was written. Initial calculation of the kidney volume shows that the method has a good accuracy. For the mean kidney dose, this method gives a satisfactory result, since the calculated value lies within the acceptable range of the central axis depth dose. Universiti Kebangsaan Malaysia 1996-03 Article PeerReviewed Supian Samat, (1996) Calculation of mean kidney dose for a Co-57 external radiation source. Sains Malaysiana, 25 (1). pp. 45-50. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol25num1_1996/vol25num1_96page45-50.html |
| repository_type |
Digital Repository |
| institution_category |
Local University |
| institution |
Universiti Kebangasaan Malaysia |
| building |
UKM Institutional Repository |
| collection |
Online Access |
| description |
A description is given of the numerical integration method for the calculation of the mean kidney dose for a Co-57 external radiation source. Based on this theory, a computer program was written. Initial calculation of the kidney volume shows that the method has a good accuracy. For the mean kidney dose, this method gives a satisfactory result, since the calculated value lies within the acceptable range of the central axis depth dose. |
| format |
Article |
| author |
Supian Samat, |
| spellingShingle |
Supian Samat, Calculation of mean kidney dose for a Co-57 external radiation source |
| author_facet |
Supian Samat, |
| author_sort |
Supian Samat, |
| title |
Calculation of mean kidney dose for a Co-57 external radiation source |
| title_short |
Calculation of mean kidney dose for a Co-57 external radiation source |
| title_full |
Calculation of mean kidney dose for a Co-57 external radiation source |
| title_fullStr |
Calculation of mean kidney dose for a Co-57 external radiation source |
| title_full_unstemmed |
Calculation of mean kidney dose for a Co-57 external radiation source |
| title_sort |
calculation of mean kidney dose for a co-57 external radiation source |
| publisher |
Universiti Kebangsaan Malaysia |
| publishDate |
1996 |
| url |
http://journalarticle.ukm.my/3678/ http://journalarticle.ukm.my/3678/ |
| first_indexed |
2023-09-18T19:39:26Z |
| last_indexed |
2023-09-18T19:39:26Z |
| _version_ |
1777405491331203072 |