Fitted curve paramaters for the efficiency of a coaxial HPGe detector
Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by...
Main Author: | |
---|---|
Format: | Article |
Published: |
Universiti Kebangsaan Malaysia
1996
|
Online Access: | http://journalarticle.ukm.my/3690/ http://journalarticle.ukm.my/3690/ |
id |
ukm-3690 |
---|---|
recordtype |
eprints |
spelling |
ukm-36902012-04-30T06:50:34Z http://journalarticle.ukm.my/3690/ Fitted curve paramaters for the efficiency of a coaxial HPGe detector Supian Samat, Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results. Universiti Kebangsaan Malaysia 1996-06 Article PeerReviewed Supian Samat, (1996) Fitted curve paramaters for the efficiency of a coaxial HPGe detector. Sains Malaysiana, 25 (2). pp. 27-34. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol25num2_1996/vol25num2_96page27-34.html |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
description |
Using Ngraph software, the parameters of various functions were determined by least squares analysis of fits to experimental efficiencies, εf of a coaxial HPGe detector for gamma rays in the energy range 59 keV to 1836 keV. When these parameters had been determined, their reliability was tested by the calculated goodness-of-fit parameter χ2cal It is shown that the function, where n = 3, gives satisfactory results. |
format |
Article |
author |
Supian Samat, |
spellingShingle |
Supian Samat, Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
author_facet |
Supian Samat, |
author_sort |
Supian Samat, |
title |
Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
title_short |
Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
title_full |
Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
title_fullStr |
Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
title_full_unstemmed |
Fitted curve paramaters for the efficiency of a coaxial HPGe detector |
title_sort |
fitted curve paramaters for the efficiency of a coaxial hpge detector |
publisher |
Universiti Kebangsaan Malaysia |
publishDate |
1996 |
url |
http://journalarticle.ukm.my/3690/ http://journalarticle.ukm.my/3690/ |
first_indexed |
2023-09-18T19:39:28Z |
last_indexed |
2023-09-18T19:39:28Z |
_version_ |
1777405493097005056 |