Activity determination of 137Cs in NPL’s ampoule using a point source

The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement wi...

Full description

Bibliographic Details
Main Author: Supian Bin Samat
Format: Article
Published: Universiti Kebangsaan Malaysia 1997
Online Access:http://journalarticle.ukm.my/3756/
http://journalarticle.ukm.my/3756/
id ukm-3756
recordtype eprints
spelling ukm-37562012-03-19T03:10:59Z http://journalarticle.ukm.my/3756/ Activity determination of 137Cs in NPL’s ampoule using a point source Supian Bin Samat, The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement with the calculated value. The same degree of deviation was obtained when the NPL standard source of equal geometry, chemical composition and density was used. Universiti Kebangsaan Malaysia 1997-09 Article PeerReviewed Supian Bin Samat, (1997) Activity determination of 137Cs in NPL’s ampoule using a point source. Sains Malaysiana, 26 (3&4). pp. 81-86. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol26num3and4_1997/vol26num3and4_97page81-86.html
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
description The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement with the calculated value. The same degree of deviation was obtained when the NPL standard source of equal geometry, chemical composition and density was used.
format Article
author Supian Bin Samat,
spellingShingle Supian Bin Samat,
Activity determination of 137Cs in NPL’s ampoule using a point source
author_facet Supian Bin Samat,
author_sort Supian Bin Samat,
title Activity determination of 137Cs in NPL’s ampoule using a point source
title_short Activity determination of 137Cs in NPL’s ampoule using a point source
title_full Activity determination of 137Cs in NPL’s ampoule using a point source
title_fullStr Activity determination of 137Cs in NPL’s ampoule using a point source
title_full_unstemmed Activity determination of 137Cs in NPL’s ampoule using a point source
title_sort activity determination of 137cs in npl’s ampoule using a point source
publisher Universiti Kebangsaan Malaysia
publishDate 1997
url http://journalarticle.ukm.my/3756/
http://journalarticle.ukm.my/3756/
first_indexed 2023-09-18T19:39:40Z
last_indexed 2023-09-18T19:39:40Z
_version_ 1777405505558282240