Activity determination of 137Cs in NPL’s ampoule using a point source
The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement wi...
| Main Author: | |
|---|---|
| Format: | Article |
| Published: |
Universiti Kebangsaan Malaysia
1997
|
| Online Access: | http://journalarticle.ukm.my/3756/ http://journalarticle.ukm.my/3756/ |
| id |
ukm-3756 |
|---|---|
| recordtype |
eprints |
| spelling |
ukm-37562012-03-19T03:10:59Z http://journalarticle.ukm.my/3756/ Activity determination of 137Cs in NPL’s ampoule using a point source Supian Bin Samat, The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement with the calculated value. The same degree of deviation was obtained when the NPL standard source of equal geometry, chemical composition and density was used. Universiti Kebangsaan Malaysia 1997-09 Article PeerReviewed Supian Bin Samat, (1997) Activity determination of 137Cs in NPL’s ampoule using a point source. Sains Malaysiana, 26 (3&4). pp. 81-86. ISSN 0126-6039 http://www.ukm.my/jsm/english_journals/vol26num3and4_1997/vol26num3and4_97page81-86.html |
| repository_type |
Digital Repository |
| institution_category |
Local University |
| institution |
Universiti Kebangasaan Malaysia |
| building |
UKM Institutional Repository |
| collection |
Online Access |
| description |
The activity of two liquid mixed radionuclide sources in NPL'S standard glass ampoules were determined by gamma-ray spectrometry measurement using a standard point source placed at 38.5 cm axially above the detector. A radio nuclide 137Cs was chosen, Results obtained were within 3% agreement with the calculated value. The same degree of deviation was obtained when the NPL standard source of equal geometry, chemical composition and density was used. |
| format |
Article |
| author |
Supian Bin Samat, |
| spellingShingle |
Supian Bin Samat, Activity determination of 137Cs in NPL’s ampoule using a point source |
| author_facet |
Supian Bin Samat, |
| author_sort |
Supian Bin Samat, |
| title |
Activity determination of 137Cs in NPL’s ampoule using a point source |
| title_short |
Activity determination of 137Cs in NPL’s ampoule using a point source |
| title_full |
Activity determination of 137Cs in NPL’s ampoule using a point source |
| title_fullStr |
Activity determination of 137Cs in NPL’s ampoule using a point source |
| title_full_unstemmed |
Activity determination of 137Cs in NPL’s ampoule using a point source |
| title_sort |
activity determination of 137cs in npl’s ampoule using a point source |
| publisher |
Universiti Kebangsaan Malaysia |
| publishDate |
1997 |
| url |
http://journalarticle.ukm.my/3756/ http://journalarticle.ukm.my/3756/ |
| first_indexed |
2023-09-18T19:39:40Z |
| last_indexed |
2023-09-18T19:39:40Z |
| _version_ |
1777405505558282240 |