Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley

Background : Nowadays, most medical laboratories in Malaysia practice occupational safety and health based on standard operating procedure and sometimes ad-hoc characteristic limited to only internal use. The level of compliance of the national occupational safety and health management system (OSHMS...

Full description

Bibliographic Details
Main Authors: I Anuar, F Zahedi, A Kadir, A.B Mokhtar
Format: Article
Language:English
Published: Department Of Community Health, Faculty of Medicine, Universiti Kebangsaan Malaysia 2008
Online Access:http://journalarticle.ukm.my/4601/
http://journalarticle.ukm.my/4601/
http://journalarticle.ukm.my/4601/1/Vol14%281%29-aniza.pdf
id ukm-4601
recordtype eprints
spelling ukm-46012016-12-14T06:36:27Z http://journalarticle.ukm.my/4601/ Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley I Anuar, F Zahedi, A Kadir, A.B Mokhtar, Background : Nowadays, most medical laboratories in Malaysia practice occupational safety and health based on standard operating procedure and sometimes ad-hoc characteristic limited to only internal use. The level of compliance of the national occupational safety and health management system (OSHMS) guidelines among medical laboratories in Malaysia is still largely unexplored. Methods : This study was carried out on 34 medical laboratories consisting of 17 public medical laboratories and 17 private medical laboratories in Klang Valley using self-administered questionnaire based on guideline of OSHMS6. This study covered 112 medical laboratories units including pathology chemistry (18), microbiology (20), virology (7), histopathology (16), cytopathology (17), hematology (19) and 15 multi discipline medical laboratories. Results : This study showed the level of compliance to the national OSHMS guideline among medical laboratories who are MS ISO 15189:2004 accredited & have a higher scores (p<0.01) in mostly measurement indicators and measurement indicators, such as element of polices (7.2% vs. 53.5%), organizing (71.5% vs. 54.9%), evaluation (77.1% vs. 52.8%) and action for improvement (86.2% vs. 50.6%) compared to those do not have that accreditation except in the of planning and implementation (86.2% vs. 50.6%) which is not significant statistically. However, there are significant difference (p<0.05) between government medical laboratories and private medical laboratories. There are no significant difference (p>0.50) between medical laboratories which have ISO 9000 quality management system certification or not compared to level of compliance to the national OSHMS guideline among medical laboratories and the laboratories operating more than 10 years compared to those with less than 10 years of operation as well towards implementing to OSHMS. Conclusion : This study showed that medical laboratory which is accredited with MS ISO 15189 is more compatible in terms of compliance to the national OSHMS guideline compared to other management system. Department Of Community Health, Faculty of Medicine, Universiti Kebangsaan Malaysia 2008 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/4601/1/Vol14%281%29-aniza.pdf I Anuar, and F Zahedi, and A Kadir, and A.B Mokhtar, (2008) Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley. Jurnal Kesihatan Masyarakat, 14 (1). pp. 39-44. ISSN 1675-1663 http://www.communityhealthjournal.org/detailarticle.asp?id=243&issue=Vol14(1):2008
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description Background : Nowadays, most medical laboratories in Malaysia practice occupational safety and health based on standard operating procedure and sometimes ad-hoc characteristic limited to only internal use. The level of compliance of the national occupational safety and health management system (OSHMS) guidelines among medical laboratories in Malaysia is still largely unexplored. Methods : This study was carried out on 34 medical laboratories consisting of 17 public medical laboratories and 17 private medical laboratories in Klang Valley using self-administered questionnaire based on guideline of OSHMS6. This study covered 112 medical laboratories units including pathology chemistry (18), microbiology (20), virology (7), histopathology (16), cytopathology (17), hematology (19) and 15 multi discipline medical laboratories. Results : This study showed the level of compliance to the national OSHMS guideline among medical laboratories who are MS ISO 15189:2004 accredited & have a higher scores (p<0.01) in mostly measurement indicators and measurement indicators, such as element of polices (7.2% vs. 53.5%), organizing (71.5% vs. 54.9%), evaluation (77.1% vs. 52.8%) and action for improvement (86.2% vs. 50.6%) compared to those do not have that accreditation except in the of planning and implementation (86.2% vs. 50.6%) which is not significant statistically. However, there are significant difference (p<0.05) between government medical laboratories and private medical laboratories. There are no significant difference (p>0.50) between medical laboratories which have ISO 9000 quality management system certification or not compared to level of compliance to the national OSHMS guideline among medical laboratories and the laboratories operating more than 10 years compared to those with less than 10 years of operation as well towards implementing to OSHMS. Conclusion : This study showed that medical laboratory which is accredited with MS ISO 15189 is more compatible in terms of compliance to the national OSHMS guideline compared to other management system.
format Article
author I Anuar,
F Zahedi,
A Kadir,
A.B Mokhtar,
spellingShingle I Anuar,
F Zahedi,
A Kadir,
A.B Mokhtar,
Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
author_facet I Anuar,
F Zahedi,
A Kadir,
A.B Mokhtar,
author_sort I Anuar,
title Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
title_short Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
title_full Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
title_fullStr Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
title_full_unstemmed Occupational safety and health management system (OSHMS) guideline compliance among medical laboratories in Klang Valley
title_sort occupational safety and health management system (oshms) guideline compliance among medical laboratories in klang valley
publisher Department Of Community Health, Faculty of Medicine, Universiti Kebangsaan Malaysia
publishDate 2008
url http://journalarticle.ukm.my/4601/
http://journalarticle.ukm.my/4601/
http://journalarticle.ukm.my/4601/1/Vol14%281%29-aniza.pdf
first_indexed 2023-09-18T19:41:58Z
last_indexed 2023-09-18T19:41:58Z
_version_ 1777405650148524032