Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor

In this study TiO2 films have been prepared using two different techniques i.e. sol-gel and electron gun evaporation (e-gun) techniques. The films were annealed at 300, 350 and 400oC in air. The microstructure study using field emission scanning electron microscopy and x-ray diffractometer showed na...

Full description

Bibliographic Details
Main Authors: Ibrahim, N.B, Yusrianto, E, Ibarahim, Z
Format: Article
Language:English
Published: Universiti Kebangsaan Malaysia 2012
Online Access:http://journalarticle.ukm.my/5426/
http://journalarticle.ukm.my/5426/
http://journalarticle.ukm.my/5426/1/14%2520N.B%2520Ibrahim.pdf
id ukm-5426
recordtype eprints
spelling ukm-54262016-12-14T06:38:25Z http://journalarticle.ukm.my/5426/ Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor Ibrahim, N.B Yusrianto, E Ibarahim, Z In this study TiO2 films have been prepared using two different techniques i.e. sol-gel and electron gun evaporation (e-gun) techniques. The films were annealed at 300, 350 and 400oC in air. The microstructure study using field emission scanning electron microscopy and x-ray diffractometer showed nanometer grains size and only the film prepared by sol-gel and annealed at 400oC has anatase phase while others are amorphous. To study the effect of the films (as buffer layer) onto the dielectric bolometer Ba0.6Sr0.4TiO3 as distance sensor, sensors with the configuration of Al/BST/TiO2/RuO2/SiO2/Si were built. Two different measurements i.e. with and without infrared source were carried out to measure the sensitivity and repeatability of the sensors. The sensors which contained sol-gel TiO2 films gave reading for both type of measurements, indicating that the sensor can act as active and passive sensors. However, the sensors which contained e-gun TiO2 films only gave responses when the IR source was used, indicating that they can only act as passive sensors. The most sensitive sensor was TiO2 film prepared by sol gel and annealed at 350oC. In general sensors which contained TiO2 films prepared by sol gel showed good repeatability. Universiti Kebangsaan Malaysia 2012-08 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/5426/1/14%2520N.B%2520Ibrahim.pdf Ibrahim, N.B and Yusrianto, E and Ibarahim, Z (2012) Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor. Sains Malaysiana, 41 (8). pp. 1029-1035. ISSN 0126-6039 http://www.ukm.my/jsm/
repository_type Digital Repository
institution_category Local University
institution Universiti Kebangasaan Malaysia
building UKM Institutional Repository
collection Online Access
language English
description In this study TiO2 films have been prepared using two different techniques i.e. sol-gel and electron gun evaporation (e-gun) techniques. The films were annealed at 300, 350 and 400oC in air. The microstructure study using field emission scanning electron microscopy and x-ray diffractometer showed nanometer grains size and only the film prepared by sol-gel and annealed at 400oC has anatase phase while others are amorphous. To study the effect of the films (as buffer layer) onto the dielectric bolometer Ba0.6Sr0.4TiO3 as distance sensor, sensors with the configuration of Al/BST/TiO2/RuO2/SiO2/Si were built. Two different measurements i.e. with and without infrared source were carried out to measure the sensitivity and repeatability of the sensors. The sensors which contained sol-gel TiO2 films gave reading for both type of measurements, indicating that the sensor can act as active and passive sensors. However, the sensors which contained e-gun TiO2 films only gave responses when the IR source was used, indicating that they can only act as passive sensors. The most sensitive sensor was TiO2 film prepared by sol gel and annealed at 350oC. In general sensors which contained TiO2 films prepared by sol gel showed good repeatability.
format Article
author Ibrahim, N.B
Yusrianto, E
Ibarahim, Z
spellingShingle Ibrahim, N.B
Yusrianto, E
Ibarahim, Z
Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
author_facet Ibrahim, N.B
Yusrianto, E
Ibarahim, Z
author_sort Ibrahim, N.B
title Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
title_short Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
title_full Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
title_fullStr Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
title_full_unstemmed Effect of different TiO2 preparation techniques on the performance of the dielectric bolometer Ba06Sr0.4TiO3 as a distance sensor
title_sort effect of different tio2 preparation techniques on the performance of the dielectric bolometer ba06sr0.4tio3 as a distance sensor
publisher Universiti Kebangsaan Malaysia
publishDate 2012
url http://journalarticle.ukm.my/5426/
http://journalarticle.ukm.my/5426/
http://journalarticle.ukm.my/5426/1/14%2520N.B%2520Ibrahim.pdf
first_indexed 2023-09-18T19:44:07Z
last_indexed 2023-09-18T19:44:07Z
_version_ 1777405785648660480