Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV
The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature prec...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Kebangsaan Malaysia
2012
|
Online Access: | http://journalarticle.ukm.my/5582/ http://journalarticle.ukm.my/5582/ http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf |
id |
ukm-5582 |
---|---|
recordtype |
eprints |
spelling |
ukm-55822016-12-14T06:38:53Z http://journalarticle.ukm.my/5582/ Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai Halimah Muhamad, The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature precipitation and solid phase extraction techniques, detected by high performance liquid chromatography-ultra violet (HPLC-UV). The HPLC separation was carried out on an AscentisTM RP-Amide column and elution with acetonitrile (solvent A) and water-methanol (2:1, v/v) (solvent B) as a suitable solvent system, at ratio of 4:6 (v/v). The optimum volume of acetonitrile for the extraction of diuron was 30 mL and 4 mL was obtained as the optimum volume of the solvent for elution analyte through the SPE cartridge. A linear correlation was obtained for the concentration of diuron from 0.05–1.0 μg mL-1 with a correlation coefficient of 0.99. The recovery of diuron from CPO was 83.2–101.4% with a relative standard deviation of 1.4–9.9% and 79.4–87.9% with relative standard deviation of 0.9–5.6% for CPKO. The method detection limit and limit of quantification obtained were 0.018 μg g-1 and 0.058 μg g-1, respectively. The method was used to determine diuron residues in palm oil from different refineries situated at different locations throughout Malaysia Universiti Kebangsaan Malaysia 2012-11 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf Mohd. Izwarie Ramli, and Zuriati Zakaria, and Ismail Sahid, and Tan, Yew Ai and Halimah Muhamad, (2012) Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV. Sains Malaysiana, 41 (11). pp. 1451-1459. ISSN 0126-6039 http://www.ukm.my/jsm/ |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Kebangasaan Malaysia |
building |
UKM Institutional Repository |
collection |
Online Access |
language |
English |
description |
The objective of this study was to develop a method for the determination of diuron (3-(3,4-dichlorophenyl)-1,1-dimethyl urea) residue in crude palm oil (CPO) and crude palm kernel oil (CPKO) matrices. The method involves the extraction of the herbicide from the oil matrix using low temperature precipitation and solid phase extraction techniques, detected by high performance liquid chromatography-ultra violet (HPLC-UV). The HPLC separation was carried out on an AscentisTM RP-Amide column and elution with acetonitrile (solvent A) and water-methanol (2:1, v/v) (solvent B) as a suitable solvent system, at ratio of 4:6 (v/v). The optimum volume of acetonitrile for the extraction of diuron was 30 mL and 4 mL was obtained as the optimum volume of the solvent for elution analyte through the SPE cartridge. A linear correlation was obtained for the concentration of diuron from 0.05–1.0 μg mL-1 with a correlation coefficient of 0.99. The recovery of diuron from CPO was 83.2–101.4% with a relative standard deviation of 1.4–9.9% and 79.4–87.9% with relative standard deviation of 0.9–5.6% for CPKO. The method detection limit and limit of quantification obtained were 0.018 μg g-1 and 0.058 μg g-1, respectively. The method was used to determine diuron residues in palm oil from different refineries situated at different locations throughout Malaysia |
format |
Article |
author |
Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai Halimah Muhamad, |
spellingShingle |
Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai Halimah Muhamad, Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
author_facet |
Mohd. Izwarie Ramli, Zuriati Zakaria, Ismail Sahid, Tan, Yew Ai Halimah Muhamad, |
author_sort |
Mohd. Izwarie Ramli, |
title |
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
title_short |
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
title_full |
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
title_fullStr |
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
title_full_unstemmed |
Determination of Herbicide Diuron levels in palm oil matrices using HPLC-UV |
title_sort |
determination of herbicide diuron levels in palm oil matrices using hplc-uv |
publisher |
Universiti Kebangsaan Malaysia |
publishDate |
2012 |
url |
http://journalarticle.ukm.my/5582/ http://journalarticle.ukm.my/5582/ http://journalarticle.ukm.my/5582/1/15%2520Mohd%2520Izwarie%2520.pdf |
first_indexed |
2023-09-18T19:44:33Z |
last_indexed |
2023-09-18T19:44:33Z |
_version_ |
1777405813078360064 |