Evaluation of particulate emission from a Palm Oil Mill Boiler
A study to investigate the particulate emission from a boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this paper. The particulate emission concentration was measured at the outlet of an 8000 kg steam/h capacity water-tube typed boile...
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universiti Kebangsaan Malaysia
2013
|
| Online Access: | http://journalarticle.ukm.my/6471/ http://journalarticle.ukm.my/6471/ http://journalarticle.ukm.my/6471/1/12_M._Rashid.pdf |
| id |
ukm-6471 |
|---|---|
| recordtype |
eprints |
| spelling |
ukm-64712016-12-14T06:41:17Z http://journalarticle.ukm.my/6471/ Evaluation of particulate emission from a Palm Oil Mill Boiler M. Rashid, Rashid W.C., Chong M. Ramli, Ramli Z.N. Zainura, Zainura J. Norruwaida, Norruwaidaaida A study to investigate the particulate emission from a boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this paper. The particulate emission concentration was measured at the outlet of an 8000 kg steam/h capacity water-tube typed boiler of a palm oil mill plant processing 27000 kg/h of fresh fruit bunch (FFB). The particulate sample was collected iso-kinetically using the USEPA method 5 sampling train through a sampling port made at the duct of the exiting flue gas between the boiler and a multi-cyclones unit. The results showed that the particulate emission rates exiting the boiler varied from 8.51 g/s to 126 g/s with an average of 44.3±31.6 g/s. In terms of concentration, the average particulate emission concentration exiting the boiler was 7.75±4.71 g/Nm3 (corrected to 7% oxygen concentration), ranging from 1.50 to 17.7 g/Nm3 (@7% O2) of the flue gas during the measurement. Based on the 27000 kg/h FFB processed, 6000 kg/h fiber and shell (F&S) burned and the capacity of the boiler of 8000 kg steam/h, the calculated particulate emission factor was 5.91±4.21 g particulate/kg FFB processed, 26.6±18.9 g particulate/kg F&S burned and 19.9±14.2 g particulate/kg boiler capacity, respectively. Based on the finding, in order to comply with the emission limits of 0.4 g/Nm3, the required collection efficiency of any given particulate pollution control system to consider for the mill will be between 73 and 98%, which is not easily achievable with the existing multi-cyclones unit. Universiti Kebangsaan Malaysia 2013-09 Article PeerReviewed application/pdf en http://journalarticle.ukm.my/6471/1/12_M._Rashid.pdf M. Rashid, Rashid and W.C., Chong and M. Ramli, Ramli and Z.N. Zainura, Zainura and J. Norruwaida, Norruwaidaaida (2013) Evaluation of particulate emission from a Palm Oil Mill Boiler. Sains Malaysiana, 42 (9). pp. 1289-1292. ISSN 0126-6039 http://www.ukm.my/jsm/ |
| repository_type |
Digital Repository |
| institution_category |
Local University |
| institution |
Universiti Kebangasaan Malaysia |
| building |
UKM Institutional Repository |
| collection |
Online Access |
| language |
English |
| description |
A study to investigate the particulate emission from a boiler of a palm oil mill plant equipped with a multi-cyclones particulate arrestor was performed and reported in this paper. The particulate emission concentration was measured at the outlet of an 8000 kg steam/h capacity water-tube typed boiler of a palm oil mill plant processing 27000 kg/h of fresh fruit bunch (FFB). The particulate sample was collected iso-kinetically using the USEPA method 5 sampling train through a sampling port made at the duct of the exiting flue gas between the boiler and a multi-cyclones unit. The results showed that the particulate emission rates exiting the boiler varied from 8.51 g/s to 126 g/s with an average of 44.3±31.6 g/s. In terms of concentration, the average particulate emission concentration exiting the boiler was 7.75±4.71 g/Nm3 (corrected to 7% oxygen concentration), ranging from 1.50 to 17.7 g/Nm3 (@7% O2) of the flue gas during the measurement. Based on the 27000 kg/h FFB processed, 6000 kg/h fiber and shell (F&S) burned and the capacity of the boiler of 8000 kg steam/h, the calculated particulate emission factor was 5.91±4.21 g particulate/kg FFB processed, 26.6±18.9 g particulate/kg F&S burned and 19.9±14.2 g particulate/kg boiler capacity, respectively. Based on the finding, in order to comply with the emission limits of 0.4 g/Nm3, the required collection efficiency of any given particulate pollution control system to consider for the mill will be between 73 and 98%, which is not easily achievable with the existing multi-cyclones unit. |
| format |
Article |
| author |
M. Rashid, Rashid W.C., Chong M. Ramli, Ramli Z.N. Zainura, Zainura J. Norruwaida, Norruwaidaaida |
| spellingShingle |
M. Rashid, Rashid W.C., Chong M. Ramli, Ramli Z.N. Zainura, Zainura J. Norruwaida, Norruwaidaaida Evaluation of particulate emission from a Palm Oil Mill Boiler |
| author_facet |
M. Rashid, Rashid W.C., Chong M. Ramli, Ramli Z.N. Zainura, Zainura J. Norruwaida, Norruwaidaaida |
| author_sort |
M. Rashid, Rashid |
| title |
Evaluation of particulate emission from a Palm Oil Mill Boiler |
| title_short |
Evaluation of particulate emission from a Palm Oil Mill Boiler |
| title_full |
Evaluation of particulate emission from a Palm Oil Mill Boiler |
| title_fullStr |
Evaluation of particulate emission from a Palm Oil Mill Boiler |
| title_full_unstemmed |
Evaluation of particulate emission from a Palm Oil Mill Boiler |
| title_sort |
evaluation of particulate emission from a palm oil mill boiler |
| publisher |
Universiti Kebangsaan Malaysia |
| publishDate |
2013 |
| url |
http://journalarticle.ukm.my/6471/ http://journalarticle.ukm.my/6471/ http://journalarticle.ukm.my/6471/1/12_M._Rashid.pdf |
| first_indexed |
2023-09-18T19:47:01Z |
| last_indexed |
2023-09-18T19:47:01Z |
| _version_ |
1777405967918432256 |