Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics

Non-invasive techniques are widely applied in process plants compared to other sensing techniques. Due to advantages such as preventing corrosion to the sensor and lengthening the sensor lifespan, this technique is also applied in process tomography such as in non-invasive ERT system. The purpose of...

Full description

Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Ruzairi, Abdul Rahim, Mohd Hafiz, Fazalul Rahiman, Leow, Pei Ling, Suzanna, Ridzuan Aw, Fazlul Rahman, Mohd Yunus, Herlina, Abdul Rahim, Herman, Wahid, Shafishuhaza, Sahlan, Mohd Amri, Md. Yunus, Norhaliza, Abdul Wahab, Azian, Abd Aziz
Format: Article
Language:English
Published: Penerbit Universiti Teknologi Malaysia 2015
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/1/Compatible%20Study%20on%20Utilizing%20Frequency%20for%20Non-Invasive%20Electrical%20Resistance%20Tomography%20Using%20COMSOL%20Multiphysics.pdf
id ump-10030
recordtype eprints
spelling ump-100302018-02-14T01:54:57Z http://umpir.ump.edu.my/id/eprint/10030/ Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics Yasmin, Abdul Wahab Ruzairi, Abdul Rahim Mohd Hafiz, Fazalul Rahiman Leow, Pei Ling Suzanna, Ridzuan Aw Fazlul Rahman, Mohd Yunus Herlina, Abdul Rahim Herman, Wahid Shafishuhaza, Sahlan Mohd Amri, Md. Yunus Norhaliza, Abdul Wahab Azian, Abd Aziz TK Electrical engineering. Electronics Nuclear engineering Non-invasive techniques are widely applied in process plants compared to other sensing techniques. Due to advantages such as preventing corrosion to the sensor and lengthening the sensor lifespan, this technique is also applied in process tomography such as in non-invasive ERT system. The purpose of this paper is to investigate the compatibility of utilizing frequency for non-invasive ERT systems. Based on quasi-static electric fields, one pair of electrodes is used to simulate the optimum frequency for the system. It was firstly derived using a mathematical equation followed by simulation using finite element model software (COMSOL Multiphysics). Results showed that by simulating several frequencies to the system, a minimum frequency that should be applied is 2 MHz to ensure that the real part of the total impedance is dominant and also to neglect the reactance part of the total impedance for the non-invasive ERT system. Thus, the non-invasive ERT system is an alternative way for the industry in monitoring the performance of process plant. Penerbit Universiti Teknologi Malaysia 2015 Article PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/10030/1/Compatible%20Study%20on%20Utilizing%20Frequency%20for%20Non-Invasive%20Electrical%20Resistance%20Tomography%20Using%20COMSOL%20Multiphysics.pdf Yasmin, Abdul Wahab and Ruzairi, Abdul Rahim and Mohd Hafiz, Fazalul Rahiman and Leow, Pei Ling and Suzanna, Ridzuan Aw and Fazlul Rahman, Mohd Yunus and Herlina, Abdul Rahim and Herman, Wahid and Shafishuhaza, Sahlan and Mohd Amri, Md. Yunus and Norhaliza, Abdul Wahab and Azian, Abd Aziz (2015) Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics. Jurnal Teknologi (Sciences and Engineering), 73 (6). pp. 65-70. ISSN 0127-9696 (print); 2180-3722 (online) http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/4408 DOI: 10.11113/jt.v73.4408
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Leow, Pei Ling
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
Herman, Wahid
Shafishuhaza, Sahlan
Mohd Amri, Md. Yunus
Norhaliza, Abdul Wahab
Azian, Abd Aziz
Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
description Non-invasive techniques are widely applied in process plants compared to other sensing techniques. Due to advantages such as preventing corrosion to the sensor and lengthening the sensor lifespan, this technique is also applied in process tomography such as in non-invasive ERT system. The purpose of this paper is to investigate the compatibility of utilizing frequency for non-invasive ERT systems. Based on quasi-static electric fields, one pair of electrodes is used to simulate the optimum frequency for the system. It was firstly derived using a mathematical equation followed by simulation using finite element model software (COMSOL Multiphysics). Results showed that by simulating several frequencies to the system, a minimum frequency that should be applied is 2 MHz to ensure that the real part of the total impedance is dominant and also to neglect the reactance part of the total impedance for the non-invasive ERT system. Thus, the non-invasive ERT system is an alternative way for the industry in monitoring the performance of process plant.
format Article
author Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Leow, Pei Ling
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
Herman, Wahid
Shafishuhaza, Sahlan
Mohd Amri, Md. Yunus
Norhaliza, Abdul Wahab
Azian, Abd Aziz
author_facet Yasmin, Abdul Wahab
Ruzairi, Abdul Rahim
Mohd Hafiz, Fazalul Rahiman
Leow, Pei Ling
Suzanna, Ridzuan Aw
Fazlul Rahman, Mohd Yunus
Herlina, Abdul Rahim
Herman, Wahid
Shafishuhaza, Sahlan
Mohd Amri, Md. Yunus
Norhaliza, Abdul Wahab
Azian, Abd Aziz
author_sort Yasmin, Abdul Wahab
title Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
title_short Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
title_full Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
title_fullStr Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
title_full_unstemmed Compatible Study on Utilizing Frequency for Non-Invasive Electrical Resistance Tomography Using COMSOL Multiphysics
title_sort compatible study on utilizing frequency for non-invasive electrical resistance tomography using comsol multiphysics
publisher Penerbit Universiti Teknologi Malaysia
publishDate 2015
url http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/
http://umpir.ump.edu.my/id/eprint/10030/1/Compatible%20Study%20on%20Utilizing%20Frequency%20for%20Non-Invasive%20Electrical%20Resistance%20Tomography%20Using%20COMSOL%20Multiphysics.pdf
first_indexed 2023-09-18T22:09:03Z
last_indexed 2023-09-18T22:09:03Z
_version_ 1777414904041439232