Analysis of Flow Characteristics in Sewerage System
In the present study, two parameters, the per capita flow and the design criterion, were investigated. The investigation was performed on a manhole located between the library and sports complex within Universiti Malaysia Pahang, Gambang campus (UMP Gambang) where field monitoring of sewage flows wa...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Trans Tech Publication
2015
|
Subjects: | |
Online Access: | http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/1/Analysis%20of%20Flow%20Characteristics%20in%20Sewerage%20System.pdf |
id |
ump-11103 |
---|---|
recordtype |
eprints |
spelling |
ump-111032018-02-06T01:46:58Z http://umpir.ump.edu.my/id/eprint/11103/ Analysis of Flow Characteristics in Sewerage System Hiew, Thong yap Ngien, S. K. TA Engineering (General). Civil engineering (General) In the present study, two parameters, the per capita flow and the design criterion, were investigated. The investigation was performed on a manhole located between the library and sports complex within Universiti Malaysia Pahang, Gambang campus (UMP Gambang) where field monitoring of sewage flows was conducted. ISCO 2150 area-velocity flowmeter was used to collect the flow data and Flowlink 5.1 software was used for data retrieval as well as display. Calibration of the flowmeter was done in the Hydraulics and Hydrology Laboratory of UMP Gambang. The study duration was from November 2014 to February 2015. Each set of data consists of sewage flow readings every 5 minutes for duration of two weeks. The same data measurement interval was applied to the rainfall data, collected through an ISCO 675 rain gauge. From the results obtained, both the parameters investigated were found to be lower than their respective values stated in the Malaysia Standard MS1228:1991. After analysis of the results, it can be concluded that the flow characteristics in the sewerage system studied is sufficient to cater to the population equivalent in the study. Trans Tech Publication 2015 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/11103/1/Analysis%20of%20Flow%20Characteristics%20in%20Sewerage%20System.pdf Hiew, Thong yap and Ngien, S. K. (2015) Analysis of Flow Characteristics in Sewerage System. Applied Mechanics and Materials, 802. pp. 599-604. ISSN 1662-7482 http://www.scientific.net/AMM.802.599 DOI: 10.4028/www.scientific.net/AMM.802.599 |
repository_type |
Digital Repository |
institution_category |
Local University |
institution |
Universiti Malaysia Pahang |
building |
UMP Institutional Repository |
collection |
Online Access |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Hiew, Thong yap Ngien, S. K. Analysis of Flow Characteristics in Sewerage System |
description |
In the present study, two parameters, the per capita flow and the design criterion, were investigated. The investigation was performed on a manhole located between the library and sports complex within Universiti Malaysia Pahang, Gambang campus (UMP Gambang) where field monitoring of sewage flows was conducted. ISCO 2150 area-velocity flowmeter was used to collect the flow data and Flowlink 5.1 software was used for data retrieval as well as display. Calibration of the flowmeter was done in the Hydraulics and Hydrology Laboratory of UMP Gambang. The study duration was from November 2014 to February 2015. Each set of data consists of sewage flow readings every 5 minutes for duration of two weeks. The same data measurement interval was applied to the rainfall data, collected through an ISCO 675 rain gauge. From the results obtained, both the parameters investigated were found to be lower than their respective values stated in the Malaysia Standard MS1228:1991. After analysis of the results, it can be concluded that the flow characteristics in the sewerage system studied is sufficient to cater to the population equivalent in the study. |
format |
Article |
author |
Hiew, Thong yap Ngien, S. K. |
author_facet |
Hiew, Thong yap Ngien, S. K. |
author_sort |
Hiew, Thong yap |
title |
Analysis of Flow Characteristics in Sewerage System |
title_short |
Analysis of Flow Characteristics in Sewerage System |
title_full |
Analysis of Flow Characteristics in Sewerage System |
title_fullStr |
Analysis of Flow Characteristics in Sewerage System |
title_full_unstemmed |
Analysis of Flow Characteristics in Sewerage System |
title_sort |
analysis of flow characteristics in sewerage system |
publisher |
Trans Tech Publication |
publishDate |
2015 |
url |
http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/ http://umpir.ump.edu.my/id/eprint/11103/1/Analysis%20of%20Flow%20Characteristics%20in%20Sewerage%20System.pdf |
first_indexed |
2023-09-18T22:11:30Z |
last_indexed |
2023-09-18T22:11:30Z |
_version_ |
1777415057995464704 |