Oxygen Stripping in Deaerator Feed Water: Condensation on Spray Droplets

Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficient...

Full description

Bibliographic Details
Main Authors: K. V., Sharma, K. V., Suryanarayana, P. K., Sarma, V., Dharma Rao, T., Subramanyam
Format: Article
Language:English
Published: Springer-Verlag 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/12407/
http://umpir.ump.edu.my/id/eprint/12407/
http://umpir.ump.edu.my/id/eprint/12407/
http://umpir.ump.edu.my/id/eprint/12407/1/Oxygen%20stripping%20in%20deaerator%20feed%20water.pdf
Description
Summary:Deaerator is used to remove oxygen from boiler feed-water. Experiments with deaerator indicate that the droplet diameter decreases with increasing the mass flow rate of water and the increasing deaerator pressure leads to increase in heat and mass transfer coefficients. The mass transfer coefficients are found to increase with increasing the deaerator pressure, the independent of length and the oxygen concentration in inlet water.