Parametric Investigation in Malaysian Separate Sewer Systems

Flow characteristics are significant in the design of sewerage systems in that poor analysis of the flow design parameters may influence the capacity of a sewerage system, causing health and environmental problems. The aim of this study is to verify the design parameters in the peak flow factor equa...

Full description

Bibliographic Details
Main Authors: Hiew, Thong Yap, Ngien, S. K., Norasman, Othman, Nadiatul Adilah, Ahmad Abdul Ghani, Norhan, Abd. Rahman
Format: Article
Language:English
Published: ICE Publishing 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/7/fkasa-2017-ngien-Parametric%20investigation.pdf
id ump-14383
recordtype eprints
spelling ump-143832017-09-08T02:46:20Z http://umpir.ump.edu.my/id/eprint/14383/ Parametric Investigation in Malaysian Separate Sewer Systems Hiew, Thong Yap Ngien, S. K. Norasman, Othman Nadiatul Adilah, Ahmad Abdul Ghani Norhan, Abd. Rahman TA Engineering (General). Civil engineering (General) Flow characteristics are significant in the design of sewerage systems in that poor analysis of the flow design parameters may influence the capacity of a sewerage system, causing health and environmental problems. The aim of this study is to verify the design parameters in the peak flow factor equation in Malaysian Standard Code of Practice MS 1228:1991. Data collection was conducted in a residential area at Taman Lepar Hilir Saujana, Kuantan, Pahang. ISCO 2150 Area Velocity Flow Meter and ISCO 674 Rain Gauge were used in this study to collect flow rate and rainfall intensity data, respectively. The resultant analysis shows that the flow design parameters, per capita flow and design criterion, were unexpectedly 42·2 and 16% lower than the value of per capita flow and design criterion described in MS 1228:1991, respectively. This indicates that the separate sewer systems in Malaysia may be overdesigned if using the flow design parameters recommended in MS 1228:1991. Thus, a revision of the flow design parameters may be necessary, taking into account the rising cost of materials around the world. ICE Publishing 2017 Article PeerReviewed application/pdf en cc_by http://umpir.ump.edu.my/id/eprint/14383/7/fkasa-2017-ngien-Parametric%20investigation.pdf Hiew, Thong Yap and Ngien, S. K. and Norasman, Othman and Nadiatul Adilah, Ahmad Abdul Ghani and Norhan, Abd. Rahman (2017) Parametric Investigation in Malaysian Separate Sewer Systems. Proceedings of the Institution of Civil Engineers - Municipal Engineer, 170 (ME2). pp. 90-96. ISSN 0965-0903 (Print); 1751-7699 (Online) http://dx.doi.org/10.1680/jmuen.16.00019 DOI: 10.1680/jmuen.16.00019
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Hiew, Thong Yap
Ngien, S. K.
Norasman, Othman
Nadiatul Adilah, Ahmad Abdul Ghani
Norhan, Abd. Rahman
Parametric Investigation in Malaysian Separate Sewer Systems
description Flow characteristics are significant in the design of sewerage systems in that poor analysis of the flow design parameters may influence the capacity of a sewerage system, causing health and environmental problems. The aim of this study is to verify the design parameters in the peak flow factor equation in Malaysian Standard Code of Practice MS 1228:1991. Data collection was conducted in a residential area at Taman Lepar Hilir Saujana, Kuantan, Pahang. ISCO 2150 Area Velocity Flow Meter and ISCO 674 Rain Gauge were used in this study to collect flow rate and rainfall intensity data, respectively. The resultant analysis shows that the flow design parameters, per capita flow and design criterion, were unexpectedly 42·2 and 16% lower than the value of per capita flow and design criterion described in MS 1228:1991, respectively. This indicates that the separate sewer systems in Malaysia may be overdesigned if using the flow design parameters recommended in MS 1228:1991. Thus, a revision of the flow design parameters may be necessary, taking into account the rising cost of materials around the world.
format Article
author Hiew, Thong Yap
Ngien, S. K.
Norasman, Othman
Nadiatul Adilah, Ahmad Abdul Ghani
Norhan, Abd. Rahman
author_facet Hiew, Thong Yap
Ngien, S. K.
Norasman, Othman
Nadiatul Adilah, Ahmad Abdul Ghani
Norhan, Abd. Rahman
author_sort Hiew, Thong Yap
title Parametric Investigation in Malaysian Separate Sewer Systems
title_short Parametric Investigation in Malaysian Separate Sewer Systems
title_full Parametric Investigation in Malaysian Separate Sewer Systems
title_fullStr Parametric Investigation in Malaysian Separate Sewer Systems
title_full_unstemmed Parametric Investigation in Malaysian Separate Sewer Systems
title_sort parametric investigation in malaysian separate sewer systems
publisher ICE Publishing
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/
http://umpir.ump.edu.my/id/eprint/14383/7/fkasa-2017-ngien-Parametric%20investigation.pdf
first_indexed 2023-09-18T22:18:04Z
last_indexed 2023-09-18T22:18:04Z
_version_ 1777415471466807296