Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle

The advancement of research and development for Electric Vehicle (EV) has pushed a similar advancement in the EV performance test and measurement. Traditionally, chassis dynamometer is used to measuring power delivered from Vehicle Under Test (VUT) typically by Internal Combustion Engine (ICE) vehic...

Full description

Bibliographic Details
Main Author: Nurul Azwa, Othman
Format: Thesis
Language:English
English
English
Published: 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/18153/
http://umpir.ump.edu.my/id/eprint/18153/
http://umpir.ump.edu.my/id/eprint/18153/1/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/18153/2/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Abstract.pdf
http://umpir.ump.edu.my/id/eprint/18153/3/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-References.pdf
id ump-18153
recordtype eprints
spelling ump-181532017-07-18T08:02:48Z http://umpir.ump.edu.my/id/eprint/18153/ Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle Nurul Azwa, Othman TK Electrical engineering. Electronics Nuclear engineering The advancement of research and development for Electric Vehicle (EV) has pushed a similar advancement in the EV performance test and measurement. Traditionally, chassis dynamometer is used to measuring power delivered from Vehicle Under Test (VUT) typically by Internal Combustion Engine (ICE) vehicle which access power by unidirectional. This one-way power delivery becomes a limitation for advanced EV with the regenerative braking feature, which the kinetic power of the vehicles is converted into electrical power. To test and measure this capability, a new chassis dynamometer is needed where the power delivery must be bidirectional. With that intention, this study proposes the usage of half-bridge bidirectional DC–DC converter (HBDC) as the Power Absorption and Delivery Unit (PADU) for a DC machine based dynamometer. PADU is controlled by modified Hysteresis Current Controller (HCC) and PID controller. The modified HCC and PID control power flow direction; back and forth during testing. The testing includes normal condition and regenerative braking condition. In normal condition, power is delivered by the DC machine whereas in regenerative braking condition, power is absorbed by the DC machine. Several test cases are considered; inclination test, declination test, normal drive condition, brake condition and stop condition. It is found that the HBDC successfully control the power flow in both normal condition and regenerative braking condition. As compared to conventional HBDC, modified HBDC reduces conduction loss with up to 28.21% reduction and switching loss with up to 7.69% reduction. To evaluate the power flow control, several power measurement points are taken in the simulation and comprehensive results are presented. Based on these results, the testing for an EV during normal condition and regenerative braking condition is achieved by successfully implement bidirectional power flow control in chassis dynamometer. 2017-02 Thesis NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/18153/1/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Table%20of%20contents.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/18153/2/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Abstract.pdf application/pdf en http://umpir.ump.edu.my/id/eprint/18153/3/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-References.pdf Nurul Azwa, Othman (2017) Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle. Masters thesis, Universiti Malaysia Pahang. http://iportal.ump.edu.my/lib/item?id=chamo:99768&theme=UMP2
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
English
English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Nurul Azwa, Othman
Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
description The advancement of research and development for Electric Vehicle (EV) has pushed a similar advancement in the EV performance test and measurement. Traditionally, chassis dynamometer is used to measuring power delivered from Vehicle Under Test (VUT) typically by Internal Combustion Engine (ICE) vehicle which access power by unidirectional. This one-way power delivery becomes a limitation for advanced EV with the regenerative braking feature, which the kinetic power of the vehicles is converted into electrical power. To test and measure this capability, a new chassis dynamometer is needed where the power delivery must be bidirectional. With that intention, this study proposes the usage of half-bridge bidirectional DC–DC converter (HBDC) as the Power Absorption and Delivery Unit (PADU) for a DC machine based dynamometer. PADU is controlled by modified Hysteresis Current Controller (HCC) and PID controller. The modified HCC and PID control power flow direction; back and forth during testing. The testing includes normal condition and regenerative braking condition. In normal condition, power is delivered by the DC machine whereas in regenerative braking condition, power is absorbed by the DC machine. Several test cases are considered; inclination test, declination test, normal drive condition, brake condition and stop condition. It is found that the HBDC successfully control the power flow in both normal condition and regenerative braking condition. As compared to conventional HBDC, modified HBDC reduces conduction loss with up to 28.21% reduction and switching loss with up to 7.69% reduction. To evaluate the power flow control, several power measurement points are taken in the simulation and comprehensive results are presented. Based on these results, the testing for an EV during normal condition and regenerative braking condition is achieved by successfully implement bidirectional power flow control in chassis dynamometer.
format Thesis
author Nurul Azwa, Othman
author_facet Nurul Azwa, Othman
author_sort Nurul Azwa, Othman
title Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
title_short Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
title_full Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
title_fullStr Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
title_full_unstemmed Modified hysteresis current controller of half bridge bidirectional DC-DC converter using chassis dynamometer for electric vehicle
title_sort modified hysteresis current controller of half bridge bidirectional dc-dc converter using chassis dynamometer for electric vehicle
publishDate 2017
url http://umpir.ump.edu.my/id/eprint/18153/
http://umpir.ump.edu.my/id/eprint/18153/
http://umpir.ump.edu.my/id/eprint/18153/1/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Table%20of%20contents.pdf
http://umpir.ump.edu.my/id/eprint/18153/2/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-Abstract.pdf
http://umpir.ump.edu.my/id/eprint/18153/3/Modified%20hysteresis%20current%20controller%20of%20half%20bridge%20bidirectional%20DC-DC%20converter%20using%20chassis%20dynamometer%20for%20electric%20vehicle-References.pdf
first_indexed 2023-09-18T22:25:32Z
last_indexed 2023-09-18T22:25:32Z
_version_ 1777415941316935680