Natural organic matter removal from surface water using submerged ultrafiltration membrane unit

This research is conducted to provide quantitative and qualitative integrated understandings of natural organic matter (NOM) fouling characteristics regarding to mechanisms and factors involved, and as well as to develop an optimization works for surface water treatment. In conjunction, a fouling be...

Full description

Bibliographic Details
Main Author: Zularisam, A. W.
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/1898/
http://umpir.ump.edu.my/id/eprint/1898/1/ZULARISAM_AB_WAHID.PDF
id ump-1898
recordtype eprints
repository_type Digital Repository
institution_category Local University
institution Universiti Malaysia Pahang
building UMP Institutional Repository
collection Online Access
language English
topic TD Environmental technology. Sanitary engineering
spellingShingle TD Environmental technology. Sanitary engineering
Zularisam, A. W.
Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
description This research is conducted to provide quantitative and qualitative integrated understandings of natural organic matter (NOM) fouling characteristics regarding to mechanisms and factors involved, and as well as to develop an optimization works for surface water treatment. In conjunction, a fouling behaviour and autopsy protocol for ultrafiltration membrane fouled with natural organic matter source waters were studied. The Ulu Pontian river, Bekok Dam water and Yong Peng water were used. Fouling characteristics were assessed by filtering the feed water with an immersed ultrafiltration polysulfone and cellulose acetate membranes that were spun by a dry-wet phase inversion spinning process. Relatively hydrophilic NOM source exhibited greater flux decline (72%) but lesser natural organic matter removal (17%) considerably due to pore adsorption, indicating that the low molecular weight (7%>30 kDa), aliphatic linear structure and neutral/base organic matter contained within the hydrophilic fraction were the prime foulants. In contrast, relatively hydrophobic natural organic matter source water that possessed higher charge density (22.63 meq/gC), greater molecular weight (24%>30 kDa) and bulky aromatic structure has shown lesser flux decline (Bekok Dam: 57%) and better NOM rejection (37%) noticeably due to cake deposition, despite filtering through a hydrophobic membrane, suggesting that the electrostatic repulsion was more influential than the steric hindrance. In comparison, a noncharged model compound of similar molecular weight was used to quantify the role of charge repulsion on NOM rejection. However, hydrophobic organic matter source of Yong Peng water has demonstrated the opposite results (flux decline: 77%), presumably due to the governing adsorptive fouling which offsett the electrostatic interactions. Analyses of permeate characteristics revealed that the hydrophobic NOM was preferentially removed by the membrane as opposed to the hydrophilic natural organic matter, hence suggesting that the charge interactions, in addition to size exclusion were more crucial to natural organic matter removal. These findings were consistent with the surrogated and fractionated natural organic matter results, which showed the hydrophilic component exhibiting the highest flux decline (52%) despite lesser dissolved organic carbon (14%) and ultraviolet 254 removal (23%) compared to hydrophobic ( 3 5%) and transphilic fractions (20%). Membrane autopsies analyses confirmed the flux decline results, resistance-in-series and penhleate analyses as membrane was mainly fouled by the hydrophilic natural organic matter rather than humic compounds. Adequacy of the present quadratic models were statistically significant to represent both the natural organic matter removal (R2 =0.966; F=49.36) and membrane permeability (R 2=O.886; F = 13.33). Alum dose exhibited the most significant factor that influenced the natural organic matter removal, followed by the two level interactions of pH and specific ultraviolet absorbance, the main effect of pH, the main effect of specific ultraviolet absorbance, the two level interaction of specific ultraviolet absorbance and alum, the second order effect of specific ultraviolet absorbance and the second order effect of pH. In he case of membrane permeability, the main effect of alum dosage and the second order effect of pH provided the principal effect, whereas the second order effect of alum, the main effect of pH, the two level interaction of pH and specific ultraviolet absorbance provided the secondary effect. Permeate quality surpassing the National Drinking Water Standards was achieved with removal up to 79.50 % of dissolved organic carbon, 87% ultraviolet absorbance, >96% of colour >99% of turbidity and with effective-cost of RM 1.12/M3, suggesting it is cost-competitive compared to conventional water treatment.
format Thesis
author Zularisam, A. W.
author_facet Zularisam, A. W.
author_sort Zularisam, A. W.
title Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
title_short Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
title_full Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
title_fullStr Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
title_full_unstemmed Natural organic matter removal from surface water using submerged ultrafiltration membrane unit
title_sort natural organic matter removal from surface water using submerged ultrafiltration membrane unit
publishDate 2008
url http://umpir.ump.edu.my/id/eprint/1898/
http://umpir.ump.edu.my/id/eprint/1898/1/ZULARISAM_AB_WAHID.PDF
first_indexed 2023-09-18T21:55:13Z
last_indexed 2023-09-18T21:55:13Z
_version_ 1777414033450729472
spelling ump-18982017-09-14T08:21:45Z http://umpir.ump.edu.my/id/eprint/1898/ Natural organic matter removal from surface water using submerged ultrafiltration membrane unit Zularisam, A. W. TD Environmental technology. Sanitary engineering This research is conducted to provide quantitative and qualitative integrated understandings of natural organic matter (NOM) fouling characteristics regarding to mechanisms and factors involved, and as well as to develop an optimization works for surface water treatment. In conjunction, a fouling behaviour and autopsy protocol for ultrafiltration membrane fouled with natural organic matter source waters were studied. The Ulu Pontian river, Bekok Dam water and Yong Peng water were used. Fouling characteristics were assessed by filtering the feed water with an immersed ultrafiltration polysulfone and cellulose acetate membranes that were spun by a dry-wet phase inversion spinning process. Relatively hydrophilic NOM source exhibited greater flux decline (72%) but lesser natural organic matter removal (17%) considerably due to pore adsorption, indicating that the low molecular weight (7%>30 kDa), aliphatic linear structure and neutral/base organic matter contained within the hydrophilic fraction were the prime foulants. In contrast, relatively hydrophobic natural organic matter source water that possessed higher charge density (22.63 meq/gC), greater molecular weight (24%>30 kDa) and bulky aromatic structure has shown lesser flux decline (Bekok Dam: 57%) and better NOM rejection (37%) noticeably due to cake deposition, despite filtering through a hydrophobic membrane, suggesting that the electrostatic repulsion was more influential than the steric hindrance. In comparison, a noncharged model compound of similar molecular weight was used to quantify the role of charge repulsion on NOM rejection. However, hydrophobic organic matter source of Yong Peng water has demonstrated the opposite results (flux decline: 77%), presumably due to the governing adsorptive fouling which offsett the electrostatic interactions. Analyses of permeate characteristics revealed that the hydrophobic NOM was preferentially removed by the membrane as opposed to the hydrophilic natural organic matter, hence suggesting that the charge interactions, in addition to size exclusion were more crucial to natural organic matter removal. These findings were consistent with the surrogated and fractionated natural organic matter results, which showed the hydrophilic component exhibiting the highest flux decline (52%) despite lesser dissolved organic carbon (14%) and ultraviolet 254 removal (23%) compared to hydrophobic ( 3 5%) and transphilic fractions (20%). Membrane autopsies analyses confirmed the flux decline results, resistance-in-series and penhleate analyses as membrane was mainly fouled by the hydrophilic natural organic matter rather than humic compounds. Adequacy of the present quadratic models were statistically significant to represent both the natural organic matter removal (R2 =0.966; F=49.36) and membrane permeability (R 2=O.886; F = 13.33). Alum dose exhibited the most significant factor that influenced the natural organic matter removal, followed by the two level interactions of pH and specific ultraviolet absorbance, the main effect of pH, the main effect of specific ultraviolet absorbance, the two level interaction of specific ultraviolet absorbance and alum, the second order effect of specific ultraviolet absorbance and the second order effect of pH. In he case of membrane permeability, the main effect of alum dosage and the second order effect of pH provided the principal effect, whereas the second order effect of alum, the main effect of pH, the two level interaction of pH and specific ultraviolet absorbance provided the secondary effect. Permeate quality surpassing the National Drinking Water Standards was achieved with removal up to 79.50 % of dissolved organic carbon, 87% ultraviolet absorbance, >96% of colour >99% of turbidity and with effective-cost of RM 1.12/M3, suggesting it is cost-competitive compared to conventional water treatment. 2008 Thesis NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/1898/1/ZULARISAM_AB_WAHID.PDF Zularisam, A. W. (2008) Natural organic matter removal from surface water using submerged ultrafiltration membrane unit. PhD thesis, Universiti Teknologi Malaysia .